  1. Experimental investigation of boiling heat transfer to R-134a refrigerant

    … specifically to tetrafluoroethane (R-134a). The refrigerants are mainly used in heat transfer applications, and due to environmental limitations, a need for assessing the suitability from a heat transfer efficiency perspective of new candidates has become a priority. The heat transfer …

    ubc Repository record for Experimental investigation of boiling heat transfer to R-134a refrigerant (opens in a new tab) Download PDF for Experimental investigation of boiling heat transfer to R-134a refrigerant (opens in a new tab)

  2. Heat transfer in microchannel geometries during condensation of R-134a

    … transfer during condensation of refrigerant R-134a in microchannel tubes was conducted. Investigations were carried out on 3 circular and 6 non-circular channels. The non-circular channels included barrel, N-shaped, rectangular, square, and triangular extruded tubes, and a channel with a …

    iastate Repository record for Heat transfer in microchannel geometries during condensation of R-134a (opens in a new tab)

  3. Hochleistungs-Verdampfer aus beschichteten Rohren zum Behältersieden von R-134A

    … des Siedenverhaltens von Kältemittel R-134a an glatten und porösen Oberflächen und beschäftigt sich mit der Herausforderung der Optimierung geeigneter Oberflächenstrukturen zur Steigerung des Wärmeübergangskoeffizienten. Die in der Einleitung vorgestellte Anforderung an immer kompaktere …

    qucosa-diss

  4. Heat transfer enhancement phenomena and pressure drop characteristics in two-phase pulsating flow using R-134A

    The heat transfer and pressure drop aspect of a saturated two-phase flow imposed to periodic inlet mass flow rate were studied using both experimental and modeling approaches. The two-phase flow of R-134 was tested in a single pass, horizontal smooth copper tube coil with a 6.2 mm (0.244-in.) inner …

    uiuc Repository record for Heat transfer enhancement phenomena and pressure drop characteristics in two-phase pulsating flow using R-134A (opens in a new tab)

  5. An experimental study of the thermal performance of R-134a and refrigerant blends in an air conditioning system

    … tests using four refrigerants, namely R-12, R-134a, and two R-22 blends;The test equipment consisted of a 3-ton vapor compression refrigeration system, an air flow loop used to control evaporator conditions, and a water flow loop used to control condenser conditions. The instrumentation …

    iastate Repository record for An experimental study of the thermal performance of R-134a and refrigerant blends in an air conditioning system (opens in a new tab)

  6. Experimental and analytical study of inverted annular flow film boiling heat transfer in a vertical tube using R-134a

    … up-flow in a round tube. The working fluid was R-134a and the flow conditions covered a pressure range of 640 to 2390 kPa (water equivalent range: 4000 to 14000 kPa) and a mass flux range of 500 to 4000 kgm-2s-1 (water equivalent range: 700 to 5700 kgm-2s-1 ). The inlet qualities of the tests …

    ottawa-retro Repository record for Experimental and analytical study of inverted annular flow film boiling heat transfer in a vertical tube using R-134a (opens in a new tab)

  7. Modeling of Mobile Air Conditioning System

    Since the conventional refrigerant R-134a is being phased out due to its high global warming potential, finding a suitable replacement refrigerant and a system design is of great importance. However, most of the alternatives are either flammable or expensive. Therefore, to ensure the safety of …

    maryland Repository record for Modeling of Mobile Air Conditioning System (opens in a new tab)

  8. In-tube evaporation and condensation heat transfer of refrigerant mixtures

    … tested and compared against R-22 were: R-134a(75%) / R-32 (25%) R-134a (90%) / R-32 (10%) R-32 (30%) / R-125 (10%) / R-134a (60%) The mixture tested and compared against R-502 was R-404A which has mass components of: R-125 (44%) / R-143a (52%) / R-134a (4%) When the R-22 substitute …

    iastate Repository record for In-tube evaporation and condensation heat transfer of refrigerant mixtures (opens in a new tab)

  9. The Effect of Carrier Type and Material Used on Results of 1,1,1,2-Tetrafluoroethane Application to Teeth

    … the refrigerant 1,1,1,2-Tetrafluoroethane (R-134a) is a common way to obtain a pulpal diagnosis. Cotton as a form of applicator is used to absorb the R-134a and create a temperature change in the pulp. There is limited research if there is a better material than cotton to generate this cold …

    wvu Repository record for The Effect of Carrier Type and Material Used on Results of 1,1,1,2-Tetrafluoroethane Application to Teeth (opens in a new tab)

  10. Using Vibration Analysis to Determine Refrigerant Levels In an Automotive Air Conditioning System

    … to determine the amount of refrigerant (R-134a) in an air conditioning system of an automobile. In the research presented, vibration analysis is examined as a possible method to determine this R-134a amount. Initial laboratory tests were completed and experimental modal analysis methods …

    vt Repository record for Using Vibration Analysis to Determine Refrigerant Levels In an Automotive Air Conditioning System (opens in a new tab)

  11. Refinement and testing of CTF for annular flow regime and incorporation of fluid properties

    … is that it lacks the capability to simulate R-134a fluids. Given there is a large database of R-134a two-phase tests, another aspect of this thesis is to extend CTF for application and validation using refrigerants. The current CTF version only supports fluid properties for water and FLiBe …

    mcmaster Repository record for Refinement and testing of CTF for annular flow regime and incorporation of fluid properties (opens in a new tab)

  12. Two-Phase Forced Convection Heat Transfer In Triple-Concentric Tube Heat Exchangers

    … this study, the condensation heat transfer of R-134a to air and water in the tubes as parallel and counter flow was investigated. In order to predict fluid dynamics behavior in the tubes, a detailed numerical modeling and three-dimensional transient simulation has been conducted by means of …

    uab Repository record for Two-Phase Forced Convection Heat Transfer In Triple-Concentric Tube Heat Exchangers (opens in a new tab)

  13. Análise de desempenho de um refrigerador de pequeno porte com drop in de refrigerantes hidrocarbonetos

    … a drinking fountain designed to work with HFC (R-134a), operating with a mixture of HC's or isobutane (R-600a) without any modification to the system or the lubricating oil. In the refrigeration laboratory of Federal University of Rio Grande do Norte were installed, in a drinking fountain, …

    brazil-ufrn Repository record for Análise de desempenho de um refrigerador de pequeno porte com drop in de refrigerantes hidrocarbonetos (opens in a new tab)

  14. A new methodology for the determination of transport properties of refrigerants

    … R-502 are primarily composed of R-32, R-125, R-134a, and R-143a. Two ternary blends reported to have potential to replace R-22 and R-502 are blend A: R-32 (23%)/R-125 (25%)/R-134a (52%) and blend B: R-125 (44%)/R-134a (4%)/R-143a (52%);Before these refrigerants can be used as working fluids in …

    iastate Repository record for A new methodology for the determination of transport properties of refrigerants (opens in a new tab)

  15. Heat transfer and flow regimes during condensation in horizontal tubes

    … mm. Four refrigerants were tested: R-12, R-22, R-134a, and azeotropic blends of R-32/R-125 in 50%/50% and 60%/40% compositions.

    uiuc Repository record for Heat transfer and flow regimes during condensation in horizontal tubes (opens in a new tab)

  16. Vapor-liquid equilibria of a low GWP refrigerant, R-1234ze(E), mixed with a POE lubricant

    … are compared to the properties of mixtures of R-134a with RL68H. In addition to providing new pure-refrigerant and refrigerant/oil property data, a comparison of the performance of five mixture models is undertaken, namely: the Wilson model, NRTL, UNIQUAC, Heil, and Raoult’s law. Overall, the …

    uiuc Repository record for Vapor-liquid equilibria of a low GWP refrigerant, R-1234ze(E), mixed with a POE lubricant (opens in a new tab)

  17. Contributions to the Measurement and Control System Design of the Carleton Supercritical Fluid Heat Transfer Test Loops

    … Water Loop (C-SCW Loop) and the Carleton R-134a Loop (C-R134a Loop) are currently being designed for experimentally investigating the convective heat transfer characteristics of supercritical fluids. This work details the selection of the flow control devices on the C-SCW Loop, the design of …

    carleton Repository record for Contributions to the Measurement and Control System Design of the Carleton Supercritical Fluid Heat Transfer Test Loops (opens in a new tab)

  18. Analyses of Variable Refrigerant Flow and Exergy in Air Conditioning Systems

    … cycle under different cooling conditions using R-134a and R-22 as refrigerants was carried out. Calculations were performed by varying different parameters such as condenser and evaporator temperatures, and refrigerant type. The R-134a refrigerant shows a better performance when multiple …

    usf Repository record for Analyses of Variable Refrigerant Flow and Exergy in Air Conditioning Systems (opens in a new tab)