Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 96 for “"R-22"”.

  1. An optical model analysis of the __Ca(p,p) __Ca reaction in the energy range r-22 MeV

    … by 40Ca over the bombarding energy range of 4-22 MeV in terms of an Optical Model. It has been found that this model, involving 10 parameters to specify the geometry and strengths of the coulomb, real, imaginary, and spin-orbit wells, furnishes an adequate description of the scattering data. In …

    rice Repository record for An optical model analysis of the __Ca(p,p) __Ca reaction in the energy range r-22 MeV (opens in a new tab)

  2. Augmentation of in-tube evaporation and condensation with micro-fin tubes using refrigerants R-113 and R-22

    … and evaporation enhancement factors for R-22 were obtained using 12.1 ft (3.68 m) long electrically heated test tubes. A reasonable similarity was found between the local evaporation data for the two different refrigerants (i.e., R-113 and R-22). Finally, the R-22 test apparatus was …

    iastate Repository record for Augmentation of in-tube evaporation and condensation with micro-fin tubes using refrigerants R-113 and R-22 (opens in a new tab)

  3. Zneškodňování odpadních plynů znečištěných freony

    … experimentálním výzkumem zneškodňování freonu R-22 (CHClF2 - chlorodifluorometan ) za různých provozních podmínek, pomocí poloprovozní experimentální jednotky, instalované v těžkých laboratořích Ústavu procesního a ekologického inženýrství v Brně. Tato jednotka umožňuje zneškodnění odpadních …

    brno-tech Repository record for Zneškodňování odpadních plynů znečištěných freony (opens in a new tab)

  4. In-tube evaporation and condensation heat transfer of refrigerant mixtures

    … for the chlorine-based refrigerants, which are R-22 and R-502. Heat transfer coefficient data were taken during in-tube evaporation and condensation of refrigerant mixtures in a 9.5 mm (3/8") O.D. smooth copper tube. The data were taken at temperatures of -2.0°C and 4.0°C for evaporation and 30°C …

    iastate Repository record for In-tube evaporation and condensation heat transfer of refrigerant mixtures (opens in a new tab)

  5. Análise experimental de sistemas de refrigeração operando com R-290 e R-600a como fluidos refrigerantes alternativos

    … Os HCFCs (hidroclorofluorcarbonos) como o R-22, por possuírem cloro em sua estrutura, também devem ser substituídos como fluidos refrigerantes. Na Europa, equipamentos novos não são produzidos com o HCFC-22, desde dezembro de 2003. Diante da necessidade de substituição desses gases nocivos ao …

    brazil-ufpe Repository record for Análise experimental de sistemas de refrigeração operando com R-290 e R-600a como fluidos refrigerantes alternativos (opens in a new tab)

  6. A new methodology for the determination of transport properties of refrigerants

    <p>R-22, R-502, and R-114 have been widely used as working fluids in refrigeration units for the past several decades. However, all of the above refrigerants have been classified as phase-out refrigerants because they are detrimental to the ozone layer. Presently, one of the leading candidates to …

    iastate Repository record for A new methodology for the determination of transport properties of refrigerants (opens in a new tab)

  7. Analysis of Heat Pump Cycles Using Thermodynamic Equations of State

    … the thermodynamic properties of refrigerant R-22 and R-152a, chosen here for illustration. In the unmodified R-K and P-R approaches, respective equations of state were used to predict vapor pressure, fugacity, enthalpy, and entropy of refrigerants. To improve the accuracy of predictive …

    odu Repository record for Analysis of Heat Pump Cycles Using Thermodynamic Equations of State (opens in a new tab)

  8. Examining Help-Seeking Intentions of Chinese Individuals: A Path Analysis

    … intention. Specifically, attitude (r = .22, p < .001) and perceived behavioral control (r = .22, p < .001) were found to be significant predictors of help-seeking intention. Based on these results, mental health professionals can design outreach interventions, such as psychoeducational …

    unt Repository record for Examining Help-Seeking Intentions of Chinese Individuals: A Path Analysis (opens in a new tab)

  9. Συσχέτιση ανδρογόνων και ινσουλίνης με την κατανομή του σωματικού λίπους σε νεαρές ελληνίδες

    … and negatively with total testosterone (r=.22, p<.025). BMI and weight were associated with insulin only (r=.24 and r=.26 respectively, p<.01). The ratio DHEAS/total testosterone were positively and independently associated with WHR 2 (r =.22, p=.015). These results provide further support …

    greece Repository record for Συσχέτιση ανδρογόνων και ινσουλίνης με την κατανομή του σωματικού λίπους σε νεαρές ελληνίδες (opens in a new tab)

  10. Análise comparativa da performance de unidades de ar condicionado tipo janela usando R22, R290 e R600a

    … de cloro em sua estrutura. Os HCFCs, como o R-22, por possuírem cloro em sua estrutura, devem ser substituídos como fluidos refrigerantes. Na Europa, equipamentos novos não são produzidos com o R-22 desde dezembro de 2003. Justamente pela ausência de átomos de cloro em sua estrutura, os …

    brazil-ufpe Repository record for Análise comparativa da performance de unidades de ar condicionado tipo janela usando R22, R290 e R600a (opens in a new tab)

  11. A techno-economical analysis of a CO2 heat pump

    … using CO2 as refrigerant arid another using R-22 as refrigerant. The comparison was based on simulated models of the mentioned heat pump systems. On comparison it was found that the CO2 heat pump has on average a 15% better COP than for R-22. This results in a 9.4% improvement in energy use for …

    nwu-za Repository record for A techno-economical analysis of a CO2 heat pump (opens in a new tab)

  12. Transferência de calor e massa de um condensador evaporativo em escala reduzida

    … fabricados no Brasil para operar com R-22 como fluido refrigerante. Este condensador tem 35 colunas e 12 fileiras de tubos de cobre de 6,35 mm de externo e opera junto a uma instalação que proporciona o escoamento de R-22 por termossifao. O distribuidor de água também foi construído em …

    brazil-ufrgs Repository record for Transferência de calor e massa de um condensador evaporativo em escala reduzida (opens in a new tab)

  13. Methods of measuring the solubility and viscosity of lubricating oil/refrigerant mixtures at high discharge pressures and temperatures

    … viscosity and density of mixtures of R-22 and of R-502 with commonly used 150 SUS lubricants have been measured by using this facility. Specifically, results for liquid mixtures of 10% to 40% refrigerant (by mass) in a 150 SUS naphthenic oil and in a 150 SUS alkylbenzene are reported …

    iastate Repository record for Methods of measuring the solubility and viscosity of lubricating oil/refrigerant mixtures at high discharge pressures and temperatures (opens in a new tab)

  14. Heat transfer and flow regimes during condensation in horizontal tubes

    … 7.04 mm. Four refrigerants were tested: R-12, R-22, R-134a, and azeotropic blends of R-32/R-125 in 50%/50% and 60%/40% compositions.

    uiuc Repository record for Heat transfer and flow regimes during condensation in horizontal tubes (opens in a new tab)

  15. Estilos de Afrontamiento y Bienestar Psicológico en Profesionales Sanitarios de Lima Metropolitana

    … relacionan negativamente con el BIEPS-A (r = -.22, p < .001) y sus dimensiones (aceptación, r = -.19, p < .010; autonomía, r = -.18, p < .010; vínculos, r = -.11, p > .050; proyectos, r = -.22, p < .010). Los resultados son discutidos dentro de la investigación.

    upc-peru Repository record for Estilos de Afrontamiento y Bienestar Psicológico en Profesionales Sanitarios de Lima Metropolitana (opens in a new tab)

  16. Fluctuations in ASHRAE Refrigerant Physical Properties and the Effect on Single and Two Phase Flow

    … volume) from five widely used refrigerants (R-22, R-134a, R-410a, R-152a, R-600a) are examined at temperatures of 100 and 40 degrees Fahrenheit. Also, standard correlations to design variables such as effect on Reynolds number are obtained using these properties. Mass flux rates of 100 and 300 …

    tamu Repository record for Fluctuations in ASHRAE Refrigerant Physical Properties and the Effect on Single and Two Phase Flow (opens in a new tab)

  17. Imagen corporal y Estilos de vida en hombres universitarios de Lima

    … y consumo de alcohol tabaco y otras drogas (r = .22; p<.01).

    upc-peru Repository record for Imagen corporal y Estilos de vida en hombres universitarios de Lima (opens in a new tab)

Page 1 of 5