Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 24 for “"R-410A"”.
-
HOT SURFACE IGNITION OF R-32 AND R-410A REFRIGERANT MIXTURES WITH LUBRICATING OIL
… the ignition characteristics of R-32 with R-410A, and the effects of lubricating oil. Unpiloted hot-plate ignition tests were carried out to determine ignition temperatures and quantify the flammability risks associated with these refrigerants. Additionally, computational fluid dynamic (CFD) …
-
Micro-channel air cooled condenser performance with two-phase flow of zeotropic refrigerant at high ambient temperatures
… condenser using zeotropic refrigerant blend R-410A operating at high reduced pressure and at hot climate was conducted. The investigation of the condensation process at high ambient temperature is worth considering because the condensation saturation temperature should be high enough to be …
-
Development of Membrane Technology for the Separation of Azeotropic Refrigerant Mixtures
… separation of the refrigerant mixture R-410A, a widely used refrigerant for residential cooling and heat pump applications. R-410A is an azeotropic, 50-50 wt% mixture of difluoromethane and pentafluoroethane. Membrane separation offers a more energy efficient alternative to traditional …
-
Improving Vapor Compression Cycle Efficiencies in Support of Conventional Refrigerant Phaseouts
Finding replacements for R-410A is paramount, and it primarily focuses on issues such as energy efficiency, GWP, flammability, toxicity, and safety. The study reported herein supports replacing R-410A by investigating reconfigurations to vapor-compression cycles and then determining performance …
-
MODELING AND PERFORMANCE EVALUATION OF COLD CLIMATE HEAT PUMP SYSTEMS IN COMMERCIAL AND RESIDENTIAL BUILDINGS
… using EnergyPlus™ as the simulation engine. R-410A serves as the baseline refrigerant, with R-454B, R-32, R-290, and R-1234yf assessed as low-GWP alternatives, using literature-based performance-scaling ratios applied under consistent system boundary conditions. R-32 emerges as the most …
-
Investigating and Modeling Pure and Binary Adsorption for Separating Azeotropic Fluorocarbon Refrigerant Mixtures
… be recycled. Focus is placed on refrigerant R‑410A, a 50/50 wt% mixture of difluoromethane (HFC‑32) and pentafluoroethane (HFC‑125), which comprises 50% of the global fluorocarbon refrigerant supply. Two main goals are emphasized: (1) understand the fundamental interactions that influence …
-
Fluctuations in ASHRAE Refrigerant Physical Properties and the Effect on Single and Two Phase Flow
… five widely used refrigerants (R-22, R-134a, R-410a, R-152a, R-600a) are examined at temperatures of 100 and 40 degrees Fahrenheit. Also, standard correlations to design variables such as effect on Reynolds number are obtained using these properties. Mass flux rates of 100 and 300 lbm/ft^2-s are …
-
Integrated Process and Molecular Design for Ionic Liquid Solvent-Based Process Intensification
… framework to separate hydrofluorocarbon (HFC), R-410A, using ionic liquids (ILs) in extractive distillation (ED) column. Our framework found [emim][dca] as the best existing IL, improving energy consumption and process sustainability by 28% and 26%, respectively, over the previously reported …
-
An Investigation of a New Refrigeration Cycle Based on Membrane Enabled Dehumidification and Cooling
… for two refrigerants, namely water and R-410A, when operating between the same temperature conditions as those of the CCP system so that comparisons could be made. Using the calculated COPs as the measure of performance, the different configurations of the CCP system were compared with …
-
Heat transfer computational methods which can also be applied to geothermal field of study for energy saving and environmental benefits
… cycle, alternative refrigerant mixtures to R-410A are proposed. Furthermore, the performance of cooling tower is evaluated with the ratio pressure drop per packing height for four packings. The results are generally applicable to the estimation of the performance of these devices and not …
-
Investigation of vapor injection heat pump system with a flash tank utilizing R410A and low-GWP refrigerant R32
… novel cycle control strategy for a residential R-410A vapor injection flash tank heat pump system was developed and experimentally investigated. The proposed cycle control strategy utilizes an electronic expansion valve (EEV) coupled with a proportional-integral-derivative (PID) controller for the …
-
Modeling and Computing Approaches for Computer-Aided Molecular and Process Design
… for the ionic liquid-based separation of R-410A, which is a widely used refrigerant mixture with high global warming potential. By integrating quantum chemical calculations, machine learning, high-throughput screening, and rigorous process optimization, we have discovered hundreds of new …
-
Modeling and Computing Approaches for Computer-Aided Molecular and Process Design
… for the ionic liquid-based separation of R-410A, which is a widely used refrigerant mixture with high global warming potential. By integrating quantum chemical calculations, machine learning, high-throughput screening, and rigorous process optimization, we have discovered hundreds of new …
-
Modeling and Computing Approaches for Computer-Aided Molecular and Process Design
… for the ionic liquid-based separation of R-410A, which is a widely used refrigerant mixture with high global warming potential. By integrating quantum chemical calculations, machine learning, high-throughput screening, and rigorous process optimization, we have discovered hundreds of new …
-
Modeling and Computing Approaches for Computer-Aided Molecular and Process Design
… for the ionic liquid-based separation of R-410A, which is a widely used refrigerant mixture with high global warming potential. By integrating quantum chemical calculations, machine learning, high-throughput screening, and rigorous process optimization, we have discovered hundreds of new …
-
Novel Fluorinated Ionic Liquid-Based Materials and Their Application in Hydrofluorocarbon Gas Uptake
… these FILs, particularly those in refrigerant R-410a, demonstrate high solubility and selective absorption of specific gases from the mixture. This work also investigates the feasibility of encapsulating FILs as a strategy for overcoming the limitations associated with bulk liquids while …
-
Characteristics of alternative fuels and alternative cooling of thermal power plants
… of preliminary investigations into the use of R-410a as a steam condenser coolant are also presented.
-
Investigation on Refrigerant Distribution in Evaporator Manifolds
… form from Watanabe et al.'s method (1995). For R-410A and R-134a tests with both inlet cases, 90% of measured vapor inlet quality data and 90% of measured liquid fraction of taken off data are within predicted values ± 0.1. To investigate the effect of refrigerant maldistribution on the …
Page 1 of 2