  1. Oil retention and pressure drop of R1234yf and R134a with POE ISO 32 in suction lines

    … it has the highest potential for oil retention. R1234yf is a new alternative refrigerant of low global warming potential (GWP) which has been developed for automobile air conditioners as a drop-in replacement for R134a in order to meet European Union’s low GWP requirement. A quantitative …

    uiuc Repository record for Oil retention and pressure drop of R1234yf and R134a with POE ISO 32 in suction lines (opens in a new tab)

  2. Estudo experimental da perda de pressão em canais convencionais com o refrigerante R1234yf em ebulição convectiva

    … be replaced. The main substitute is the fluid R1234yf, which is already being used in the automotive industry. The R1234yf has a GWP lower to 1. This work presents the theoretical and experimental study of the pressure drop of the refrigerant R1234yf on boiling in a horizontal smooth tube. …

    brazil-ufmg Repository record for Estudo experimental da perda de pressão em canais convencionais com o refrigerante R1234yf em ebulição convectiva (opens in a new tab)

  3. Análise comparativa e modelo de simulação de um climatizador veicular com condensadores a R1234yf/água e R134a/ar

    … with water cooled condenser and the ecofluid R1234yf. To establish the corresponding comparative analysis, mathematical models were developed for the two systems. A methodology from the literature was also used to estimate the thermal load in the cabin of a car in order to support the …

    brazil-ufmg Repository record for Análise comparativa e modelo de simulação de um climatizador veicular com condensadores a R1234yf/água e R134a/ar (opens in a new tab)

  4. Investigation of oil retention and pressure drop in suction lines using R1234yf, R134a and R410A with POE ISO 100

    … and pressure drop in suction lines using R1234yf, the low Global Warming Potential (GWP) refrigerant which was developed as a consequence of the European Union’s Mobile Air-Conditioning Directive. Tests were conducted in 10.2 mm internal diameter horizontal and vertical suction lines that …

    uiuc Repository record for Investigation of oil retention and pressure drop in suction lines using R1234yf, R134a and R410A with POE ISO 100 (opens in a new tab)

  5. Estudio del fluido R1234yf como sustituto directo de bajo potencial de calentamiento global al R134a. Análisis teórico y evaluación experimental

    … fluido de bajo potencial de calentamiento global R1234yf como substituto directo al R134a en ciclos de compresión de vapor. La metodología utilizada se ha basado en la evaluación teórica y experimental del uso del R1234yf , como alternativa de sustitución directa al R134a. Para ello se ha …

    barcelona Repository record for Estudio del fluido R1234yf como sustituto directo de bajo potencial de calentamiento global al R134a. Análisis teórico y evaluación experimental (opens in a new tab)

  6. An Investigation of Void Fraction for Low GWP Refrigerants

    … of the void fraction for R134a, R290, and R1234yf were conducted for low mass flux conditions at air-conditioning evaporator temperatures. Test sections of round tube inner diameters 2.99 and 4.56 mm were tested. Flow visualization was performed on the 4.56 mm test section. Results of the …

    maryland Repository record for An Investigation of Void Fraction for Low GWP Refrigerants (opens in a new tab)

  7. Energetic, economic and environmental analysis of a direct-expansion heat pump assisted by photovoltaic-thermal panel for domestic hot water heating operating with low-GWP refrigerants

    … comparar o COP e a potência gerada com R134a, R1234yf, R290, R600a, R513A, R454C e R455A. Além disso, o SPF e o TEWI foram calculados considerando a média horária da irradiação solar, temperatura ambiente, temperatura do ponto de orvalho e velocidade do vento das 7h00 às 18h00 no ano de 2024 …

    brazil-ufmg Repository record for Energetic, economic and environmental analysis of a direct-expansion heat pump assisted by photovoltaic-thermal panel for domestic hot water heating operating with low-GWP refrigerants (opens in a new tab)

  8. Estudo experimental do coeficiente de transferência de calor local por condensação do refrigerante R1234yf em um tubo horizontal liso com diâmetro interno de 4,8 mm

    … condensation heat transfer coefficient for the R1234yf fluid for mass velocities of 150 kg/(m².s), 200 kg/(m².s), 250 kg/(m².s) and 300 kg/(m².s), saturation temperatures of 30ºC and 35ºC and qualitys steam of 10% to 90%. The experimental results were analyzed among themselves and in relation to …

    brazil-ufmg Repository record for Estudo experimental do coeficiente de transferência de calor local por condensação do refrigerante R1234yf em um tubo horizontal liso com diâmetro interno de 4,8 mm (opens in a new tab)

  9. Numeric model of a direct expansion solar assisted heat pump water heater operating with low GWP refrigerants (R1234YF,R290, R600A and R744) for replacement of R134A

    … with low GWP analyzed are R290, R600a, R744, and R1234yf. R290 has better COP for solar radiation between 50 W/m2 and 700 W/m2, as well as for environment temperature between 10oC and 35oC. On the other hand, for solar radiation less than 50 W/m2, the R134a has better COP than R290. Environmental …

    brazil-ufmg Repository record for Numeric model of a direct expansion solar assisted heat pump water heater operating with low GWP refrigerants (R1234YF,R290, R600A and R744) for replacement of R134A (opens in a new tab)

  10. Análise baseada nos 4E de um sistema de refrigeração doméstico acoplado a um PCM utilizando o algoritmo de otimização ACVO

    … using the refrigerant fluids R134a, R600a, R1234yf, and R290. The operational conditions were optimized using the anti-coronavirus optimization algorithm. A comparative analysis was carried out using the energetic, exergetic, environmental, and economic approaches, to guide which fluid was …

    brazil-ufmg Repository record for Análise baseada nos 4E de um sistema de refrigeração doméstico acoplado a um PCM utilizando o algoritmo de otimização ACVO (opens in a new tab)

  11. Analytical and experimental investigation of two-phase ejector cycles using low-pressure refrigerants

    … compared to expansion valve cycles. R134a and R1234yf were used as the working fluids in the experimental tests. These lowpressure working fluids offer less improvement potential with ejector cycles because of their lower throttling loss, compared to CO2. It was found that two-phase ejectors …

    uiuc Repository record for Analytical and experimental investigation of two-phase ejector cycles using low-pressure refrigerants (opens in a new tab)

  12. Determinação da fração de vazio pelo método QCV para escoamentos bifásicos horizontais do refrigerante HFO-1234yf

    … void fraction in two-phase horizontal flows with R1234yf fluid. The object of the study was the determination of the void fraction for a large range of quality and for some values of mass flow and saturation temperature of the flu-id. The R1234yf is one of the candidates for replacing the R134a …

    brazil-ufmg Repository record for Determinação da fração de vazio pelo método QCV para escoamentos bifásicos horizontais do refrigerante HFO-1234yf (opens in a new tab)

  13. Tiempo de vida útil de la espuma formada en mezclas de refrigerantes R134a y R1234yf con aceite POE ISO10 cuando son sometidas a una caída de presión controlada

    … formación de espuma en mezclas R134a/POE ISO10 y R1234yf/POE ISO10, llegando a identificarse que dicho proceso consta de dos etapas principales: una etapa de crecimiento y otra de caída de la altura de la capa de espuma, las cuales se dan a velocidades distintas. Asimismo, se identificó que el …

    pucp-peru-2 Repository record for Tiempo de vida útil de la espuma formada en mezclas de refrigerantes R134a y R1234yf con aceite POE ISO10 cuando son sometidas a una caída de presión controlada (opens in a new tab)

  14. Distribution of refrigerant and lubricant in automotive air conditioning systems

    … and its new environmental friendly alternative R1234yf are used with PAG 46 oil as working fluid at different Oil Circulation Ratio (OCR), ranging from 2% to 4%. Experiments are conducted in two system, one with a fixed Orifice Tube (OT) and low pressure side accumulator, the other with a …

    uiuc Repository record for Distribution of refrigerant and lubricant in automotive air conditioning systems (opens in a new tab)

  15. Improvements on performance of a heat pump water heater system

    … pattern of water in tank, drop-in refrigerant R1234yf and condenser configuration. This study examines two different models, HPWH-66 and HPWH-50. Simulation is employed and suggestions are made towards a better performance. The performance of HPWH system is found to strongly depend on the …

    uiuc Repository record for Improvements on performance of a heat pump water heater system (opens in a new tab)

  16. Control and commissioning of a hot-gas bypass compressor load stand for testing light-commercial compressors using low-GWP refrigerants

    … (GWP). Many low-GWP refrigerants, such as R1234yf, R1234ze(E), R1234ze(D), R32, and several blends of these, are being considered as replacements. This creates a need for design changes to compressors. Recent work by Schmidt et al. (2019) presented a hot-gas bypass compressor load stand …

    okstate Repository record for Control and commissioning of a hot-gas bypass compressor load stand for testing light-commercial compressors using low-GWP refrigerants (opens in a new tab)

  17. Experimentally validated models of refrigerant distribution in microchannel heat exchangers used to evaluate charge reduction of various working fluids

    … different refrigerants including R290, R717, R1234yf, and R134a are used to validate the models. The experimentally validated models are used to compare the charge of various refrigerants. The procedure for charge reduction analysis described in the thesis is the reduction of the internal …

    uiuc Repository record for Experimentally validated models of refrigerant distribution in microchannel heat exchangers used to evaluate charge reduction of various working fluids (opens in a new tab)

  18. Evaporation of pure fluids and mixtures in a microchannel tube

    … tube. Six pure fluids (R134a, R32, R1234ze(E), R1234yf, R1233zd(E), and R1336mzz(Z)) are tested, and they have significant difference in properties. The experiments are conducted in a 24-port microchannel tube with an averaged hydraulic diameter of 0.643 mm. The tested microchannel has hydraulic …

    uiuc Repository record for Evaporation of pure fluids and mixtures in a microchannel tube (opens in a new tab)

  19. ANALYSIS OF LOW GLOBAL WARMING POTENTIAL FLUORIDE WORKING FLUIDS IN VAPOUR COMPRESSION SYSTEMS. EXPERIMENTAL EVALUATION OF COMMERCIAL REFRIGERATION ALTERNATIVES

    … drop-in or retrofit alternatives. Thus, R1234yf, R1234ze(E) and R450A were proposed to replace R134a and R448A to substitute R404A. The theoretical performance of the different low-GWP alternative fluids, as an overview of their potential use, has been studied at typical parallel …

    upv Repository record for ANALYSIS OF LOW GLOBAL WARMING POTENTIAL FLUORIDE WORKING FLUIDS IN VAPOUR COMPRESSION SYSTEMS. EXPERIMENTAL EVALUATION OF COMMERCIAL REFRIGERATION ALTERNATIVES (opens in a new tab)

  20. Thermo-economic and environmental analysis of a refrigeration system operating with ecological refrigerants

    … nos refrigerantes R290, R600a, R744 e R1234yf. A análise ambiental foi realizada com base no Impacto Total de Aquecimento Equivalente, enquanto a análise termo-econômica foi realizada com base no Coeficiente de Performance, Eficiência Exergética e Taxa de Custo Total da Planta. Para as …

    brazil-ufmg Repository record for Thermo-economic and environmental analysis of a refrigeration system operating with ecological refrigerants (opens in a new tab)