Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 122 for “"R134a"”.

  1. Spray cooling with R134a

    … a lower boiling point compared with water. Using R134a in a VCC win mix oil with the Rl34a in order to lubricate the compressor. Mixing of oil is hypothesized to affect the heat transfer coefficient, as it has been shown to affect heat transfer in the pool boiling and flow boiling processes. The …

    ucf Repository record for Spray cooling with R134a (opens in a new tab)

  2. Flow boiling of R134a in vertical mini-diameter tubes

    … pressure drop and flow visualization of R134a in small to mini/micro-diameter tubes. The experimental facility was first designed and constructed by X. Huo (2005) with the contribution of L. Chen (2006). In the present study, the experimental facility was upgraded by changing the heating …

    brunel Repository record for Flow boiling of R134a in vertical mini-diameter tubes (opens in a new tab)

  3. Experimental investigation of an R134a based organic Rankine cycle

    … is used to boil the pressurised working fluid, R134a, using a hot air as heat source. The expander used is a scroll type, coupled to a generator, which is able to produce maximum 1.6 kW output. Experimental data of the heat engine are measured under different operating conditions and utilized in …

    uoit Repository record for Experimental investigation of an R134a based organic Rankine cycle (opens in a new tab)

  4. An experimental facility for microchannel research and evaporating R134a in microchannel tube

    … testing results of the facility with evaporating R134a are given. Both heat transfer coefficient and pressure drop are measured and reported in this thesis. The conclusion gives a brief summary of this thesis. The appendix has included calibration data from section 2 and raw data from section 4.

    uiuc Repository record for An experimental facility for microchannel research and evaporating R134a in microchannel tube (opens in a new tab)

  5. A Two-Phase Cooling Method Using R134a Refrigerant to Cool Power Electronics Devices

    … submerged in an automotive refrigerant bath (R134a). The circuit was then tested while being cooled using a mock automotive air conditioning system. Tests were performed on custom made thin-film resistors while being cooled by the same mock air conditioning system. The thin-film resistors were …

    ut-knoxville Repository record for A Two-Phase Cooling Method Using R134a Refrigerant to Cool Power Electronics Devices (opens in a new tab)

  6. Performance comparativa entre R437A e R134A paradrop-in em um condicionador de ar automotivo

    … work aims to evaluate the conditions of use of R134A refrigerant (used in vehicles) and compare with R437A (alternative refrigerant), varying the speed of the electric fan in the evaporator. All tests were performed in automotive air conditioning unit ATR600, simulating the thermal conditions of …

    brazil-ufrn Repository record for Performance comparativa entre R437A e R134A paradrop-in em um condicionador de ar automotivo (opens in a new tab)

  7. Performance comparativa entre R290/R600a (50:50) e R134a para drop-in em refrigerador doméstico

    … analysis of R290/R600a (50:50) compared to R134a and other mass fractions of the hydrocarbons mixtures in the standard ASHRAE refrigeration cycle in order to compare the operational characteristics and thermodynamic properties of fluids based on the software REFPROP 6.0. The characteristics …

    brazil-ufrn Repository record for Performance comparativa entre R290/R600a (50:50) e R134a para drop-in em refrigerador doméstico (opens in a new tab)

  8. An Experimental Investigation On The Dynamics Of Bubbles Utilizing Refrigerant R134a Under Pressurized Flow Boiling Conditions

    Flow boiling heat transfer allows for the dissipation of large amounts of heat. In this work, the effect of heat flux and pressure on flow boiling of liquid refrigerant R-134a is studied in a vertical thin channel. The experimental setup mimics a refrigeration cycle and specifically looks at the …

    ucf Repository record for An Experimental Investigation On The Dynamics Of Bubbles Utilizing Refrigerant R134a Under Pressurized Flow Boiling Conditions (opens in a new tab)

  9. Investigation of oil retention and pressure drop in suction lines using R134a with AB ISO 32

    … pressure drop in suction lines for a mixture of R134a as refrigerant and AB ISO 32 as the lubricating oil. The oil retention and pressure drop were evaluated in horizontal and vertical suction lines with an internal diameter of 10.2 mm and length approximately 2 m. The system operating conditions …

    uiuc Repository record for Investigation of oil retention and pressure drop in suction lines using R134a with AB ISO 32 (opens in a new tab)

  10. Oil retention and pressure drop of R1234yf and R134a with POE ISO 32 in suction lines

    … air conditioners as a drop-in replacement for R134a in order to meet European Union’s low GWP requirement. A quantitative comparison of oil retention and pressure drop characteristics of R1234yf and R134a with POE32 oil in 10.2 mm inside diameter horizontal and vertical suction lines at …

    uiuc Repository record for Oil retention and pressure drop of R1234yf and R134a with POE ISO 32 in suction lines (opens in a new tab)

  11. Modeling And Testing Of R23/R134a Mixed Refrigerant System With Water Cooled Separator For Low Temperature Refrigeration

    Low temperature (LT, -35 °C to -50 °C) and ultra low temperature (ULT, -50 °C to -100 °C) refrigeration is required in the life sciences industry for the production and storage of biological systems. The minimum practical storage temperature of a simple, single-stage refrigeration system is -30 °C, …

    marquette Repository record for Modeling And Testing Of R23/R134a Mixed Refrigerant System With Water Cooled Separator For Low Temperature Refrigeration (opens in a new tab)

  12. Modeling heat rejection in horizontal smooth round tubes and experimental validation for R1234ze(E), R134a and R32

    … and compared to experimental data for R134a, R1234ze(E) and R32 for mass fluxes of 100-300 kgm-2s-1, saturation temperatures of 30 0C - 50 0C and from sub-cooling of 20 0C to superheat of 50 0C in a horizontal smooth tube with 6.1 mm inner diameter. Cavallini et al. (2006) and …

    uiuc Repository record for Modeling heat rejection in horizontal smooth round tubes and experimental validation for R1234ze(E), R134a and R32 (opens in a new tab)

  13. Investigation of oil retention and pressure drop in suction lines using R1234yf, R134a and R410A with POE ISO 100

    … 1-6 m/s. Experiments were also performed in R134a in order to study if R1234yf is a suitable drop-in replacement for R134a. Also, comparisons were made with data obtained using POE ISO 32 to study the effect of lubricant viscosity. Experimental tests in R410A using POE 32 and POE 100 served …

    uiuc Repository record for Investigation of oil retention and pressure drop in suction lines using R1234yf, R134a and R410A with POE ISO 100 (opens in a new tab)

  14. Experimental Investigation of Spray Cooling Integrated With a Modified Vapor Compression Refrigeration System Using Several Refrigerants

    … ammonia, and refrigerants such as R113 and R134a. Their studies indicate that the usage of dielectric fluids as a working fluid in spray cooling systems is promising and has significant thermal performance enhancement, which is suitable for a wide range of electronic applications. However, …

    south-carolina Repository record for Experimental Investigation of Spray Cooling Integrated With a Modified Vapor Compression Refrigeration System Using Several Refrigerants (opens in a new tab)

  15. An Investigation of Void Fraction for Low GWP Refrigerants

    … of fluids. Measurements of the void fraction for R134a, R290, and R1234yf were conducted for low mass flux conditions at air-conditioning evaporator temperatures. Test sections of round tube inner diameters 2.99 and 4.56 mm were tested. Flow visualization was performed on the 4.56 mm test section. …

    maryland Repository record for An Investigation of Void Fraction for Low GWP Refrigerants (opens in a new tab)

  16. ANALYSIS OF LOW GLOBAL WARMING POTENTIAL FLUORIDE WORKING FLUIDS IN VAPOUR COMPRESSION SYSTEMS. EXPERIMENTAL EVALUATION OF COMMERCIAL REFRIGERATION ALTERNATIVES

    … supermarkets are using refrigerants (mainly R134a, R404A and R507A) with great impact (high GWP values) on the climate change due to leakages, especially from parallel compressor rack DX systems. Recently, some regulations and directives have been approved to limit GWP values of HFC used in …

    upv Repository record for ANALYSIS OF LOW GLOBAL WARMING POTENTIAL FLUORIDE WORKING FLUIDS IN VAPOUR COMPRESSION SYSTEMS. EXPERIMENTAL EVALUATION OF COMMERCIAL REFRIGERATION ALTERNATIVES (opens in a new tab)

  17. Heat waste recovery system from exhaust gas of diesel engine to a reciprocal steam engine

    … working fluids. The chosen working fluid, R134a, was used to operate at the dry condition when it exited the steam piston engine. Furthermore, R134a is environmentally friendly with low environmental impact. It was also compatible with sealing materials. There were calibrations for the …

    texas Repository record for Heat waste recovery system from exhaust gas of diesel engine to a reciprocal steam engine (opens in a new tab)

  18. Experimental and theoretical investigation of novel phase change materials for thermal applications

    … properties, behaviour and characteristics of R134a clathrates with additives, as phase change materials (PCMs). PCMs’ charging characteristics are analysed and evaluated for cooling applications. The formation of refrigerant clathrates is investigated due to their potential use in active as …

    uoit Repository record for Experimental and theoretical investigation of novel phase change materials for thermal applications (opens in a new tab)

Page 1 of 7