Effect of longitudinal micro fin tube enhancement in evaporation of R410A
… an internal diameter of 6.3 mm. The study used R410A at a saturation temperature of 10 °C running at mass fluxes from 100 to 250 kg/m2-s, heat fluxes from 4 to 14 kW/m2, and qualities from 0.1 to 0.8. The testing facility had a 15 cm long test section heated by a secondary heated water loop, a …
-
Supercritical gas cooling and condensation of refrigerant R410A at near-critical pressures
… heat transfer and pressure drop of refrigerant R410A during condensation and supercritical cooling at near-critical pressures was conducted. Investigations were carried out at five nominal pressures: 0.8, 0.9, 1.0, 1.1 and 1.2xpcrit. The refrigerant was tested in commercially available …
-
Comparison of refrigerants R410a and R404a for use in low temperature applications: A computer model study
… a perspective for comparison of refrigerant R410a with R404a. As R410a is now widely used commercially, further knowledge is desired on how different an R410a system is from established refrigerant systems and any possibilities for retrofitting. This thesis uses a computer model simulation to …
-
Oil Retention and Pressure Drop in Horizontal and Vertical Suction Lines with R410A / POE ISO 32
… to circulate POE (polyolester) oil and R410A at a controlled mass flux, OCR (oil in circulation ratio), and apparent superheat, and to directly measure the pressure drop and mass of oil retained in horizontal and vertical suction lines. The bulk vapor velocity and overall void fraction …
-
Investigation of vapor injection heat pump system with a flash tank utilizing R410A and low-GWP refrigerant R32
… are facing the challenges of being phased out. R410A, with a GWP of 2,088, has been widely used in residential air-conditioners and heat pump systems. A potential substitute for R410A is R32, which has a GWP of 675. This research work also investigates the performance difference using R410A and …
-
Carbon Dioxide and R410A Flow Boiling Heat Transfer, Pressure Drop, and Flow Pattern in Horizontal Tubes at Low Temperatures
… the evaporation temperature of -30°C. Also, R410A and R22 flow boiling heat transfer coefficients and pressure drop in a macro-scale (6.1 mm) tube were measured, and they are compared with CO2. This comparison presents that the CO2 flow boiling heat transfer coefficients are higher than R410A …
-
Investigation of oil retention and pressure drop in suction lines using R1234yf, R134a and R410A with POE ISO 100
… of lubricant viscosity. Experimental tests in R410A using POE 32 and POE 100 served as data for further comparison. Results show that at similar operating conditions, the more viscous POE 100 yields upto 40 % more oil retention and upto 60 % more pressure drop in comparison to POE 32. It was …
-
Design, build-up, and commissioning of R410A chiller facility for experimental investigation into the effect of compressor capacity modulation strategies on seasonal performance
Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2024-05-01
-
Design, Testing And Controls For Air Source Heat Pump System In Cold Climates Using Natural & Conventional Refrigerants
… natural refrigerant and conventional refrigerant R410A have been tested and analyzed comparatively to determine the feasibility of air source heat pump systems for space heating applications in northeastern U.S winter climates by replacing the natural gas based heating system as part of the global …
-
Supercritical Gas Cooling and Near-Critical-Pressure Condensation of Refrigerant Blends in Microchannels
… was conducted. The azeotropic refrigerant blend R410A (equal parts of R32 and R125 by mass) has zero ODP and has properties similar to R22, and is therefore of interest for vapor compression cycles in high-temperature-lift space-conditioning and water heating applications. Smaller tubes lead to …
-
A model for improvement of water heating heat exchanger designs for residential heat pump water heaters : a thesis presented in fulfilment of the requirement for the degree of Master of Engineering at Massey University, Palmerston North, New Zealand
… than one and three zone models. The models for a R410A subcritical heat pump and a CO2 transcritical heat pump were used to investigate the effect of key design parameters by varying water or refrigerant flow channel size for three water heating heat exchanger configurations: circular …
-
Potentials for COP increase in vapor compression systems
… expansion valve system operating with R410A. The two major mechanisms of improvement of the ejector system were quantified separately: COP gains between 1.9% to 8.4% were solely due to the work recovery, while liquid-feeding the evaporator alone was responsible for 4.9% to 9.0% of COP …
-
Design and Lab Implementation of an Air Source Transcritical CO2 Heat Pump
… was benchmarked using a commercially available R410A heat pump manufactured by LG. The climate chamber maintained steady-state outdoor conditions by combining continuous cooling from the system’s original evaporator coil with resistive heating controlled via feedback loops. Custom controllers …
-
A Prediction Model for Adiabatic and Diabatic Capillary Tubes with Alternative Refrigerants
… of each individual refrigerant (R-134a, R-22, R410a) in the adiabatic capillary tubes were generated, as well as for each refrigerant (R-134a, R-22, R410a, R600) in the capillary tubes/suction line heat exchangers. The average deviations of the specific refrigerant correlations range from 1.27% …
-
Low flammability hydrofluorocarbon working fluids for cryogenic-enhanced Organic Rankine Cycles
… cryogenic-enhanced ORC was constructed, using R410A, hot water, and liquid nitrogen as the working fluid, heat source, and cryogenic heat sink, respectively. The parametric study included varying working fluid flow rates and evaporation temperatures. The operational flexibility, namely …
-
Dynamic Modeling of Vapor Compression Systems for Residential Heat Pump Applications with Alternative Low-GWP Refrigerants
… have been proposed as drop-in replacements for R410A in residential heat pumps. This thesis presents the development of a modeling framework in Simulink® for the dynamic simulations of such residential heat pumps. The framework is component-based, allowing arbitrary cycle configurations, and …
-
Refrigerant Charge Distribution in Unitary Air-conditioning Units
… was proposed and implemented. Refrigerant R410A charge distribution tests were conducted under steady-state conditions and the results were compared with published results of the refrigerant charge distribution in various types of air-conditioning units. It was concluded that the system …
-
Étude des effets d'injections sur le comportement de nouveaux mélanges de réfrigérants en écoulement diphasique
… à base de HFC. Notamment, le R404A, R407C, R410A et le R507. La méthode analysée est la méthode par injections. Plus précisément, par l'injection de liquide, de vapeur chaude et de mélange de liquide et de vapeur chaude. Le comportement en condensation ainsi que celui en ébullition y sont …
-
Experimental evaluation and modeling of engine driven heat pump
… a GHP in high ambient operating conditions using R410A as a refrigerant is firstly included in this study. Computational fluid dynamics (CFD) techniques have been used to study the design of the heat exchangers to improve system performance during heating and cooling operations with refrigerant …
-
Analyse et modélisation d'une pompe à chaleur géothermique à expansion directe
… géothermique à expansion directe utilisant le R410A, le R407C et le R22 comme réfrigérants a été présentée dans la troisième partie. L'objectif principal est de retenir le meilleur réfrigérant capable de remplacer R22 qui sera bientôt éliminé en raison de l’entrée en vigueur du protocole de …
Page 1 of 3