Results 1 to 20 of 27 for “"R600a"”

  1. Performance comparativa entre R290/R600a (50:50) e R134a para drop-in em refrigerador doméstico

    … and cycling (on-off) tests to the mixture R290/R600a (50:50) in domestic refrigerator. It was first developed an computational analysis of R290/R600a (50:50) compared to R134a and other mass fractions of the hydrocarbons mixtures in the standard ASHRAE refrigeration cycle in order to compare the …

    brazil-ufrn Repository record for Performance comparativa entre R290/R600a (50:50) e R134a para drop-in em refrigerador doméstico (opens in a new tab)

  2. Análise comparativa da performance de unidades de ar condicionado tipo janela usando R22, R290 e R600a

    Há uma crescente preocupação mundial a respeito da destruição da camada de ozônio envolvendo a terra. Os CFCs, como o R-12, foram identificados como de alto poder destruidor da camada de ozônio (ODP), pela presença de cloro em sua estrutura. Os HCFCs, como o R-22, por possuírem cloro em sua …

    brazil-ufpe Repository record for Análise comparativa da performance de unidades de ar condicionado tipo janela usando R22, R290 e R600a (opens in a new tab)

  3. Sustainable design of hydrocarbon refrigerants applied to the hermetic compressor

    … by hydrocarbon (HC) refrigerants such as R600a in much of the domestic European and Asian markets. Despite this, there has been little research into the long-term environmental consequences of their application. Domestic refrigeration compressors were analysed to ascertain the tribological …

    bournemouth Repository record for Sustainable design of hydrocarbon refrigerants applied to the hermetic compressor (opens in a new tab)

  4. Análise da interação compressor-tubo capilar na adaptação de um sistema de refrigeração de R134a para R290 ou R600

    … replace the R134a by more ecological fluids as R600a and R290. In that way, this monograph has as principal objective to analyze the transition of a refrigeration system, which works originally with R134a, to R600a and R290. For that, it was realized a theoretical comparison study, looking for …

    brazil-ufscar Repository record for Análise da interação compressor-tubo capilar na adaptação de um sistema de refrigeração de R134a para R290 ou R600 (opens in a new tab)

  5. Numeric model of a direct expansion solar assisted heat pump water heater operating with low GWP refrigerants (R1234YF,R290, R600A and R744) for replacement of R134A

    … The refrigerants with low GWP analyzed are R290, R600a, R744, and R1234yf. R290 has better COP for solar radiation between 50 W/m2 and 700 W/m2, as well as for environment temperature between 10oC and 35oC. On the other hand, for solar radiation less than 50 W/m2, the R134a has better COP than …

    brazil-ufmg Repository record for Numeric model of a direct expansion solar assisted heat pump water heater operating with low GWP refrigerants (R1234YF,R290, R600A and R744) for replacement of R134A (opens in a new tab)

  6. Comparative Life Cycle Assessment of CFC-replacement Compounds in Different Technical Applications

    … (R30), propane (R290), isobutane (R600a), carbon dioxide (R744), pentafluorodimethyl ether (E125), 1,1,1’,1’-tetrafluorodimethyl ether (E134), hepta-fluoropropyl methyl ether (E7000), methyl nonafluorobutyl ether (E7100), ethyl nonafluorobutyl ether (E7200), and 1,1-difluoroethane …

    bayreuth Repository record for Comparative Life Cycle Assessment of CFC-replacement Compounds in Different Technical Applications (opens in a new tab)

  7. Análise baseada nos 4E de um sistema de refrigeração doméstico acoplado a um PCM utilizando o algoritmo de otimização ACVO

    … equipment using the refrigerant fluids R134a, R600a, R1234yf, and R290. The operational conditions were optimized using the anti-coronavirus optimization algorithm. A comparative analysis was carried out using the energetic, exergetic, environmental, and economic approaches, to guide which …

    brazil-ufmg Repository record for Análise baseada nos 4E de um sistema de refrigeração doméstico acoplado a um PCM utilizando o algoritmo de otimização ACVO (opens in a new tab)

  8. Análise tribo-termodinâmica da aplicação de nanopartículas de Al2O3 como aditivo lubrificante em compressor hermético de refrigeração

    … of the refrigerating system using R134a or R600a as refrigerants. The study looked at the influences of variables: i) refrigerant charge (100, 110, 120 and 130 g), ii) rotational speed of the condenser blower (800 and 1100 RPM) and iii) nanoparticle concentration (0.1 and 0.5 g/l) on the …

    brazil-ufrn Repository record for Análise tribo-termodinâmica da aplicação de nanopartículas de Al2O3 como aditivo lubrificante em compressor hermético de refrigeração (opens in a new tab)

  9. Avaliação numérica dos efeitos da perda de pressão em sistemas de refrigeração por compressão mecânica em cascata

    … como pares de fluidos o R134a/R23, R125/R32, R600a/R290, Amônia/Etano, R12/R13 e R404A/R410A, para carga térmica de 500 W, e diâmetros de canais entre 6,35 e 12,70 mm. A partir das análises realizadas, constata-se que a perda de pressão ao longo do evaporado pode apresentar significativo …

    brazil-uff Repository record for Avaliação numérica dos efeitos da perda de pressão em sistemas de refrigeração por compressão mecânica em cascata (opens in a new tab)

  10. Study and development of low-GWP mixtures for commercial condensing units and ultra-low temperature systems

    … based on liquid density. The optimal mixture (R600a/R1150 [70/30%]) and system enhancements, such as a capillary optimization, compressor replacement and recuperative low-temperature heat exchanger, increased COP from 0.144 to 0.338. Overall, this work proposes efficient, lower-impact …

    barcelona Repository record for Study and development of low-GWP mixtures for commercial condensing units and ultra-low temperature systems (opens in a new tab)

  11. Evaluation of two-phase evaporation pressure drop correlations for low refrigerant mass flux.

    … under 70 kg/m2s for two refrigerants, R134A and R600A, internal diameters of aluminum evaporators ranging from 0.186 to 0.317 inches, U-bend internal radii ranging from 0.342 to 0.750 inches in horizontal and vertical orientations of evaporators. The geometry of the samples closely resembled a …

    louisville Repository record for Evaluation of two-phase evaporation pressure drop correlations for low refrigerant mass flux. (opens in a new tab)

  12. Yapıştırma bağlantılı soğutucu boru birleşimlerinde tırtıl çekme (knurling) işlemi ile elde edilen yüzey desenlerinin bağlantı dayanımına etkisinin deneysel incelenmesi

    … içerisinden geçirilen soğutucu akışkan gaz (R600a – R134a v.b.) sayesinde soğutma çevrimi tamamlanmaktadır. Yüksek enerji verimliliğine sahip ürünler tasarlanabilmesi için sistem tasarımında kullanılan boru bağlantılarının yüksek sızdırmazlık ve basınç altında görevlerini yerine getirmeleri …

    ogu-tr Repository record for Yapıştırma bağlantılı soğutucu boru birleşimlerinde tırtıl çekme (knurling) işlemi ile elde edilen yüzey desenlerinin bağlantı dayanımına etkisinin deneysel incelenmesi (opens in a new tab)

  13. Bir minikanallı buharlaştırıcının performansının deneysel olarak araştırılması

    … deneylerde soğutkan olarak 58 gr R600a gazı kullanılmıştır.Çalışmanın sonucunda, mini kanallı buharlaştırıcı ısı transfer kapasitesi (UA) değerleri kanatlı borulu buharlaştırıcı UA değerlerinden % 21 oranında daha küçük olduğu, bununla birlikte ölçülen buharlaşma sıcaklıkları …

    ogu-tr Repository record for Bir minikanallı buharlaştırıcının performansının deneysel olarak araştırılması (opens in a new tab)

  14. Thermo-economic and environmental analysis of a refrigeration system operating with ecological refrigerants

    … global, concentrando-se nos refrigerantes R290, R600a, R744 e R1234yf. A análise ambiental foi realizada com base no Impacto Total de Aquecimento Equivalente, enquanto a análise termo-econômica foi realizada com base no Coeficiente de Performance, Eficiência Exergética e Taxa de Custo Total da …

    brazil-ufmg Repository record for Thermo-economic and environmental analysis of a refrigeration system operating with ecological refrigerants (opens in a new tab)

  15. Kondenser fan tipinin ev tipi bir derin dondurucunun enerji tüketimine etkisi

    … litre brüt hacminde ve soğutucu akışkan olarak R600a kullanılan bir derin dondurucu kullanılmıştır. Yapılan tüm deneylerde VNTZ130 model ASHRAE standartlarına göre 1.75 COP'ye sahip hermetik tip kompresör tercih edilmiştir. Soğutma çevriminde kısılma işlemini sağlayan kılcal borunun toplam …

    ogu-tr Repository record for Kondenser fan tipinin ev tipi bir derin dondurucunun enerji tüketimine etkisi (opens in a new tab) Restricted access

  16. Experimental based numerical investigation of microchannel condenser integrated freezers

    … are compared at 25 ambient temperature. R600a is used as a refrigerant in both systems. Variable capacity compressor is also used to investigate the effect of compressor speed on both types of condensers used in the system. Additionally, fan motor which cools the condensers is selected as …

    metu Repository record for Experimental based numerical investigation of microchannel condenser integrated freezers (opens in a new tab)

  17. Análise teórico-experimental de separadores de fases para refrigeração doméstica

    … mm. Os testes foram realizados com isobutano (R600a) em condições típicas de refrigeração doméstica, cujas vazões mássicas entre 0,5 a 3,0 kg/h e título entre 10 a 25% na entrada dos separadores. O separador de 6,35 mm separou as fases com relativa eficiência até 1,5 kg/h. Em vazões maiores …

    brazil-ufsc Repository record for Análise teórico-experimental de separadores de fases para refrigeração doméstica (opens in a new tab)

  18. Technoecomonic optimization and working fluid selection for an engine coolant driven turbo-compression cooling system

    … fluids (R134a, R152a, R245fa, R1234ze(E), and R600a) were studied for this application to better understand the effects of fluid properties on technical and economic system performance. A coupled thermodynamic, heat exchanger, and economic model was developed to calculate the payback period of …

    colostate Repository record for Technoecomonic optimization and working fluid selection for an engine coolant driven turbo-compression cooling system (opens in a new tab)

  19. Caracterização de escoamentos rarefeitos de fluídos refrigerantes com um novo método para medição de vazão em microcanais

    … The flow of N2 and refrigerant fluids R134a and R600a were analyzed in stainless steel, copper and brass metal microtubes in practically the entire range of slip and transition regimes. The values of the slip coefficient and tangential momentum accommodation coefficient (TMAC) were obtained by …

    brazil-ufsc Repository record for Caracterização de escoamentos rarefeitos de fluídos refrigerantes com um novo método para medição de vazão em microcanais (opens in a new tab)

  20. Estudo experimental e modelagem baseado na análise dos 4E de uma bomba de calor assistida por energia solar

    … R1233zd(E), R170, R290, R600, R1270 and R600a). The environmental analysis is based on the total equivalent warming impact (TEWI) and the economic analysis is based on the payback. In addition, the mathematical model of the system was validated using the infrared thermography technique. …

    brazil-ufmg Repository record for Estudo experimental e modelagem baseado na análise dos 4E de uma bomba de calor assistida por energia solar (opens in a new tab)

Page 1 of 2