Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"R744"”.

  1. Tepelné čerpadlo země - voda s chladivem R744

    … navrhnout tepelné čerpadlo země-voda s chladivem R744 pro nízko-teplotní vytápění. Práce je rozdělena do dvou hlavních částí, kdy v první je vysvětlen princip a rozdělení tepelného čerpadla, popis jednotlivých komponentů a rozdíly chladiv. V praktické části je navrhnut a vypočítán chladivový …

    brno-tech Repository record for Tepelné čerpadlo země - voda s chladivem R744 (opens in a new tab)

  2. Experimental and Analytical Investigation of a Two-Phase Ejector Used for Expansion Work Recovery in a Transcritical R744 Air-Conditioning System

    … of the transcritical carbon dioxide (CO2, R744) refrigeration cycle, the supercritical heat rejection pressure can be used to maximize the system performance. In addition, large throttling losses make R744 a suitable fluid for expansion work recovery. This study presents experimental and …

    uiuc Repository record for Experimental and Analytical Investigation of a Two-Phase Ejector Used for Expansion Work Recovery in a Transcritical R744 Air-Conditioning System (opens in a new tab)

  3. Design, Testing And Controls For Air Source Heat Pump System In Cold Climates Using Natural & Conventional Refrigerants

    … be a good alternative to the HFC refrigerants. R744 has zero ozone depletion potential (ODP) and a global warming potential (GWP) of 1 which is almost thousand times lower than the HFC refrigerants. In this study, air source heat pump systems with natural refrigerant and conventional refrigerant …

    cuny Repository record for Design, Testing And Controls For Air Source Heat Pump System In Cold Climates Using Natural & Conventional Refrigerants (opens in a new tab)

  4. A model for improvement of water heating heat exchanger designs for residential heat pump water heaters : a thesis presented in fulfilment of the requirement for the degree of Master of Engineering at Massey University, Palmerston North, New Zealand

    … R410A and di of 7 mm and Di −d2 of 1.0 mm for R744. The optimal flow channels for the flat tube-on-tube configuration with b1i (major length of the refrigerant flow channel) and b2i (major length of the water flow channel) both of 9 mm were found to be a1i (minor length of the refrigerant flow …

    massey Repository record for A model for improvement of water heating heat exchanger designs for residential heat pump water heaters : a thesis presented in fulfilment of the requirement for the degree of Master of Engineering at Massey University, Palmerston North, New Zealand (opens in a new tab)

  5. Comparative Life Cycle Assessment of CFC-replacement Compounds in Different Technical Applications

    … (R290), isobutane (R600a), carbon dioxide (R744), pentafluorodimethyl ether (E125), 1,1,1’,1’-tetrafluorodimethyl ether (E134), hepta-fluoropropyl methyl ether (E7000), methyl nonafluorobutyl ether (E7100), ethyl nonafluorobutyl ether (E7200), and 1,1-difluoroethane (R152a). The data …

    bayreuth Repository record for Comparative Life Cycle Assessment of CFC-replacement Compounds in Different Technical Applications (opens in a new tab)

  6. Potentials for COP increase in vapor compression systems

    … investigated for R410A and transcritical R744. Experiments were carried out in a limited range of operating conditions but an experimentally validated model was used to extrapolate trends. As the relative size of the HXs was increased, a maximum COP of 9.5 (without fans power) was …

    uiuc Repository record for Potentials for COP increase in vapor compression systems (opens in a new tab)

  7. Thermal-fluid performance modelling of a transcritical carbon dioxide heat pump cycle

    … natural refrigerants, with Carbon Dioxide (R744) being a promising candidate due to its competitive heat transfer properties and negligible environmental impact. When operated in a transcritical heat pump cycle, R744 can heat water to above-conventional temperatures such as 90°C without a …

    nwu-za Repository record for Thermal-fluid performance modelling of a transcritical carbon dioxide heat pump cycle (opens in a new tab)

  8. Energy-based visualisation of a transcritical CO₂ heat pump cycle

    … The use of refrigerant grade carbon dioxide (R744) in refrigeration systems as an alternative working fluid shows great promise due to its inert properties and its minor environmental impact. It has an ozone depletion potential (ODP) of zero and global warming potential (GWP) of one. The use …

    nwu-za Repository record for Energy-based visualisation of a transcritical CO₂ heat pump cycle (opens in a new tab)

  9. Role of internal heat exchanger in air conditioning systems

    … potential substitution of refrigerants (R134a, R744 and R1234yf among them). It provide extra heat transfer between the high temperature liquid from the condenser and the cold vapor from the evaporator, which can lower the inlet quality to the evaporator and potentially increase system capacity …

    uiuc Repository record for Role of internal heat exchanger in air conditioning systems (opens in a new tab)

  10. Vortex control of two-phase refrigerant flow in nozzles and its application in ejector vapor compression cycles

    … the influence of vortex control on transcritical R744 ejector and cycle performance has been experimentally investigated. Vortex control was applied to ejectors with different geometric parameters. The performance of ejector and ejector cycle with vortex control was compared with those of the …

    uiuc Repository record for Vortex control of two-phase refrigerant flow in nozzles and its application in ejector vapor compression cycles (opens in a new tab)

  11. Development and Validation of a Minichannel Evaporator Model under Dehumidification

    … ºC, ±5%, and ±20%, respectively. For the CO2 (R744) minichannel evaporator studied, the presented model estimated the cooling capacity and outlet air temperature within error bands of ±10% and ±1.0 ºC, respectively. Regarding the CO2 pressure drop, the Fin1D-MB model generally underpredicted …

    upv Repository record for Development and Validation of a Minichannel Evaporator Model under Dehumidification (opens in a new tab)

  12. Flash gas bypass concept utilizing low pressure refrigerants

    … As the advantages of flash gas removal in R744 systems are observed, it is of scientific interest to elaborate the same approach in R134a or similar low pressure refrigerant A/C systems. The main reason for this is the fact that lower pressure fluids are more affected by pressure drop, …

    uiuc Repository record for Flash gas bypass concept utilizing low pressure refrigerants (opens in a new tab)

  13. Scuffing and wear of engineering materials under different lubrication regimes in the presence of environmentally friendly refrigerants

    … as water, air, and ammonia, carbon dioxide (CO2, R744) is an attractive and possibly the most viable candidate. Although, CO2 is a non-flammable and non toxic natural refrigerant (being not the case for Hydrocarbons and Ammonia), one of the main drawbacks related to its implementation as a …

    uiuc Repository record for Scuffing and wear of engineering materials under different lubrication regimes in the presence of environmentally friendly refrigerants (opens in a new tab)

  14. Cascade and Secondary Coolant Supermarket Refrigeration Systems: Modelling and New Frost Correlations

    … expressions for carbon dioxide-ammonia (R744-R717) cascade refrigeration system; (b) mathematical expressions for frost property and air pressure drop; and (c) a numerical model for medium-temperature secondary coolant system incorporating the new frost property correlations. The …

    auckland-ms Repository record for Cascade and Secondary Coolant Supermarket Refrigeration Systems: Modelling and New Frost Correlations (opens in a new tab)

  15. Optimization, control, and implementation of CO2 transcritical air conditioning systems

    … as of model year 2021. Carbon dioxide CO2 (R744) has been revived as a natural environmentally friendly refrigerant and is considered a strong alternative to R134a as it has a global warming potential (GWP) of 1 compared to 1300 for R134a. In an air-conditioning system and due to the …

    msu Repository record for Optimization, control, and implementation of CO2 transcritical air conditioning systems (opens in a new tab)

  16. Techno-economic feasibility study of an urban rooftop ice rink- Integrating with Rosenlundsverket district energy in central Gothenburg

    … CO₂ transcritical refrigeration technology (R744) as the primary cooling system due to its superior environmental credentials and high efficiency in Nordic climates. Through detailed performance modeling using Danfoss Coolselector®2 professional software and ASPEN Plus® validation, combined …

    chalmers Repository record for Techno-economic feasibility study of an urban rooftop ice rink- Integrating with Rosenlundsverket district energy in central Gothenburg (opens in a new tab)

  17. Experimental and numerical investigation of the design and control of vapor-compression systems with integration of two-phase ejectors for performance enhancement through expansion work recovery

    … high throttling loss, such as transcritical CO2 (R744) systems, should use the ejector to directly supplement compressor power using the pressure increase provided by the ejector, while systems using lower-pressure refrigerants should use the ejector to improve the performance of the evaporator by …

    uiuc Repository record for Experimental and numerical investigation of the design and control of vapor-compression systems with integration of two-phase ejectors for performance enhancement through expansion work recovery (opens in a new tab)

  18. A Comparison of Fault Detection Methods For a Transcritical Refrigeration System

    When released into the atmosphere, traditional refrigerants contribute to climate change several orders of magnitude more than a corresponding amount of carbon dioxide. For that reason, an increasing amount of interest has been paid to transcritical vapor compression systems in recent years, which …

    tamu Repository record for A Comparison of Fault Detection Methods For a Transcritical Refrigeration System (opens in a new tab)