Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 122 for “"RBE"”.
-
Reference Radiation for Cosmic Rays in RBE Research
… a function of depth in a tissue equivalent absorber as determined by Geant4 simulation.
-
Variable relative biological effectiveness (RBE) in proton therapy of gliomas
… der relativen biologischen Wirksamkeit (RBE) in der Protonentherapie zu berücksichtigen. Hier wurde die Variabilität der RBE für späte strahleninduzierte Hirnverletzungen (RIBI) untersucht, die nach einer Protonentherapie von Gliom-Hirntumorpatienten diagnostiziert wurden. Eine …
-
Μικροδοσιμετρικά μοντέλα υπολογισμού του RBE στην αδρονιακή θεραπεία με έμφαση στο μοντέλο RMF / Microdosimetric models for RBE calculation in hadron therapy: focus on the RMF model
… υπολογίζονται παραμετροποιημένες σχέσεις για το RBE (για βιολογικό αποτέλεσμα DSB) ως συνάρτηση της ποσότητας (Zeff/β)2, η οποία περιγράφει χαρακτηριστικά του ιόντος. Επίσης ήταν αναγκαίο να υπολογιστεί η παράμετρος zF. Στην παρούσα εργασία υπολογίστηκε η γραμμιώδης και ειδική ενέργεια με την …
-
Ανάλυση βάσεων δεδομένων για το RBE ακτίνων-Χ, ηλεκτρονίων και αδρονίων
… προσδιοριστεί με δύο διαφορετικούς ορισμούς το RBE, ηλεκτρονίων και πρωτονίων σε ανθρώπινα κύτταρα, για διάφορα ποσοστά συγκέντρωσης οξυγόνου 100%, 20% (τυπική φυσιολογική οξυγόνωση) και 1% (υποξία) και να πραγματοποιηθεί η μεταξύ τους σύγκριση. Χρησιμοποιήθηκε ο κώδικας Monte Carlo Damage …
-
The relative biological effectiveness (RBE) of a 200–MeV clinical proton beam
… study, the relative biological effectiveness (RBE) values for the 200-MeV clinical proton beam at iThemba LABS were measured at strategic positions along a 5 cm Spread-Out-Bragg-Peak (SOBP). RBE values were evaluated at the initial plateau of the virgin beam (24.2 mm in Perspex), and at the …
-
Παρουσίαση του κώδικα MCDS και εφαρμογές στον υπολογισμό του RBE για ηλεκτρόνια
… της σχετικής βιολογικής αποτελεσματικότητας (RBE) για ηλεκτρόνια μεσω διαφορετικών προσεγγίσεων όπως τα μοντέλα DSB yield και η απλοποιημένη σχέση του Kellerer. Επίσης εξετάζει τη χρήση του κώδικα fast Monte Carlo Damage Simulation (MCDS) για τον υπολογισμό της σημαντικότερης βλάβης στα …
-
A Novel ‘In-Silico’ Method for Modeling the RBE of Clinical Proton Beams
This thesis explores the variability of RBE in proton therapy, highlighting its dependence not only on LET but also on various biological factors. Employing a novel approach, this study first conducts a Monte Carlo simulation of a clinical SOBP (with parameters from the Emory Proton Therapy Center) …
-
Υπολογισμός του RBE για δέσμες πρωτονίων ενέργειας 1-250 MeV: Σύγκριση εμπειρικών και βιοφυσικών μοντέλων
… ότι η σχετική βιολογική αποτελεσματικότητα (RBE) των πρωτονίων είναι σταθερή και ίση με 1.1. Τα πειραματικά δεδομένα, ωστόσο, δείχνουν ότι το RBE δεν είναι σταθερό, αλλά εξαρτάται από πολλούς παράγοντες όπως η δόση, η ποιότητα της ακτινοβολίας, ο τύπος του ιστού και το βιολογικό αποτέλεσμα. …
-
Asking for more information: Can recognition-based enhancements (RBE) made to internal facial features produce more accurate composites?
… to make recognition-based enhancements (RBE) to the internal facial features of a composite, leads to subsequent improvements in composite accuracy. Across four experiments, participants were presented with an unfamiliar target face (for 60 seconds) and then constructed a composite …
-
Biblioteca escolar : à procura da sua acção pedagógica : uma visão sobre o percurso de bibliotecas escolares integradas na RBE
Questionamos, neste estudo, se a acção pedagógica das bibliotecas escolares tem correlação na acção educativa da escola. Dá-se conta da revisão da literatura em áreas como o novo paradigma de educação que vai emergindo, a gestão do conhecimento, a qualidade e eficácia das escolas enquanto …
-
Evaluation of Relative Biological Effectiveness for Proton Therapy
… ratio of 1.1. However, experiments show that the RBE is higher in different portions in proton ranges. Since the usage of a constant RBE is justified based on experiments conducted using older methods of dose delivery, the re-evaluation of using a constant RBE and proposing models for determining …
-
A double strand DNA break model of photon and electron relative biological effectiveness
… studies find inconsistencies between low-LET RBE and the ICRP's current radiation weighting factor. Generally, there is evidence that dependence exists between radiation energy and radiation RBE where lower energy radiations tend to have a greater biological effect than higher energy …
-
As escolas e o Programa Rede de Bibliotecas Escolares : um estudo sobre os processos de desenvolvimento das bibliotecas integradas na RBE
… integradas na Rede de Bibliotecas Escolares (RBE) Num primeiro momento, apontamos algumas das linhas de força que caracterizam a actual sociedade de informação, para uma melhor contextualização da missão e objectivos das bibliotecas escolares. Fazemos o levantamento de alguns dos mais …
-
Black-Box Barriers Behind Registration-Based Encryption
Registration-Based Encryption (RBE) is a cryptographic primitive designed to achieve the functionalities of Identity-Based Encryption (IBE) while avoiding the key-escrow problem. In an RBE system, participants generate their own secret and public keys and register their public keys with a …
-
Modeling Proton Relative Biological Effectiveness Using Monte Carlo Simulations of Microdosimetry
… an enhanced relative biological effectiveness (RBE) compared to photons. In the current clinical standard, RBE is fixed at 1.1 at all points along the proton beam, meaning protons are assumed to require 10% less dose than photons to achieve target coverage and organ at risk (OAR) sparing. …
-
Uncertainty In The Physical Basis of Estimates of Relative Biological Effectiveness In Carbon Radiotherapy
… is the relative biological effectiveness (RBE) of the beam (i.e., how biologically potent carbon ions are as compared to x-rays), which is significantly elevated. This RBE also varies as a function of many parameters, and there are currently several models implemented in clinical and …
-
Assessing The Potential Clinical Impact of Variable Biological Effectiveness In Proton Radiotherapy
… protons a relative biological effectiveness (RBE) value of 1.1 corresponding to 10% increased effectiveness compared to photon radiation. Numerous studies have shown, however, that the RBE value of protons is variable and can deviate substantially from 1.1, but experimental data on RBE and …
-
Enhancement of anti-HIV-1 Ribozyme Activities by Rev Binding and Multimerization
… env transcript termed the Rev Binding Element (RBE). In anti-HIV gene therapy employing ribozymes to increase the co-localization of anti- HIV ribozymes with target HIV mRNAs, it has been proposed that when the native HIV- 1 RBE is appended to a ribozyme as a decoy molecule, simultaneous binding …
-
Quantifying Uncertainty In A Measurement-Based Assessment of Relative Biological Effectiveness In Carbon Ion Radiotherapy
… in relative biological effectiveness (RBE), a value that is calculated via one of several clinically implemented algorithms. This study investigates the uncertainty in measured microdosimetric parameters for RBE calculation by the Microdosimetric Kinetic Model (MKM), Repair Misrepair …
-
Herstellung optimierter Sf9-Zelllinien für die Baculovirus-basierte Produktion rekombinanter AAV5-Vektoren mit hoher Infektiosität
… rAAV Fremd-DNA-Verpackung auf. Ziel dieser Arbeit war deshalb die Herstellung stabiler Sf9-Zelllinien zur Produktion transduktionsoptimierter rAAV5 auf Basis eines erhöhten VP1-Anteils im rAAV5 Kapsid. Im Verlauf der Arbeit wurde die erhöhte Verpackung von Fremd-DNA auf die Rep-Bindestelle …
Page 1 of 7