Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"RC Walls"”.

  1. Finite Element Analysis of RC Walls with Complex Configurations

    Slender RC walls are used commonly in mid- and high-rise buildings to resist lateral loads arising from earthquakes and wind forces. To accommodate architectural constraints, facilitate construction, and maximize structural efficiency, the majority of these walls have complex configurations, …

    washington Repository record for Finite Element Analysis of RC Walls with Complex Configurations (opens in a new tab)

  2. Seismic analysis and evaluation of a building retrofitted with new RC walls

    … building in Mexico City. The original lateral force resisting system consisted of reinforced concrete (RC) columns supporting waffle slabs along with RC walls located in the elevator core. After having suffered damages during an earthquake in 2017, the building was retrofitted by adding new RC …

    texas Repository record for Seismic analysis and evaluation of a building retrofitted with new RC walls (opens in a new tab)

  3. Behavior and Kinematic-Based Modeling of Short RC Walls under Seismic Loading

    … of seismic damage and failures in short walls, this work is a study on predicting their behavior. This was achieved by an experimental study and development/evaluation of several methods of analyses with varying complexity. The main goal was to develop simple and reliable procedures based …

    liege Repository record for Behavior and Kinematic-Based Modeling of Short RC Walls under Seismic Loading (opens in a new tab) Download PDF for Behavior and Kinematic-Based Modeling of Short RC Walls under Seismic Loading (opens in a new tab)

  4. Seismic Design of Lightly Reinforced Concrete Walls

    … in New Zealand, several lightly reinforced concrete (RC) walls in multi-storey buildings formed only a limited number of cracks at the wall base with fracture of vertical reinforcement observed. Initial investigation highlighted that the vertical reinforcement content was a key …

    auckland-ms Repository record for Seismic Design of Lightly Reinforced Concrete Walls (opens in a new tab)

  5. Post-earthquake assessment of damaged and repaired reinforced concrete wall buildings

    … Approximately 60% of the multi-storey reinforced concrete (RC) buildings in the Christchurch Central Business District were demolished after these earthquakes, even when only minor structural damage was present. Several factors influenced the decision of demolition instead of repair, one of …

    auckland-ms Repository record for Post-earthquake assessment of damaged and repaired reinforced concrete wall buildings (opens in a new tab)

  6. Seismic Strengthening of Reinforced Concrete Walls Using Fiber-Reinforced Polymer Confinement of Boundary Regions

    … methods among the various options. This researchaimstoaddress this gap by focusing on the development of a seismic strengthening methodologyforthe confinement of reinforced concrete (RC) walls, which are commonly employed as lateral load resisting elements but often lack sufficient boundary …

    auckland-ms Repository record for Seismic Strengthening of Reinforced Concrete Walls Using Fiber-Reinforced Polymer Confinement of Boundary Regions (opens in a new tab)

  7. Modeling of existing and rehabilitated reinforced concrete buildings

    … or design was for lower levels of seismic forces. One of the major challenges that faces structural engineers is to determine the seismic capacity of an existing building and to rehabilitate these buildings to upgrade their seismic capacity if needed. At present, there are no guidelines …

    mcmaster Repository record for Modeling of existing and rehabilitated reinforced concrete buildings (opens in a new tab)

  8. Influence of Dynamic Load Rates on the Seismic Response of Reinforced Concrete Walls

    … failure modes occurred for lightly reinforced concrete walls, such as a lack of cracking in the wall plastic hinge region and premature bar buckling/fracture. In response to these observations, several amendments were made to the New Zealand Concrete Structures Standard, including revised …

    auckland-ms Repository record for Influence of Dynamic Load Rates on the Seismic Response of Reinforced Concrete Walls (opens in a new tab)

  9. Seismic Performance Quantification of Reinforced Concrete Shear Walls with Different End Configurations: Experimental Assessment and Data-driven Performance Models

    Well-detailed reinforced concrete (RC) shear walls did not achieve the expected seismic performance in the 2011 Christchurch earthquake as per the Canterbury earthquake royal commission report. Similarly, RC shear walls showed low seismic performance in the 2010 Maule earthquake. The two major …

    mcmaster Repository record for Seismic Performance Quantification of Reinforced Concrete Shear Walls with Different End Configurations: Experimental Assessment and Data-driven Performance Models (opens in a new tab)

  10. Performance of Flexure-Controlled Reinforced Concrete Structural Walls Under Sequential Fire-Earthquake Loads

    The performance of reinforced concrete (RC) structural walls under individual hazards has been well studied. However, little is known regarding the behavior of RC structural walls under sequential hazards. The research presented here seeks to address the performance of RC structural walls under …

    tamu Repository record for Performance of Flexure-Controlled Reinforced Concrete Structural Walls Under Sequential Fire-Earthquake Loads (opens in a new tab)

  11. Wall-to-Floor Interaction in Reinforced Concrete Buildings

    The poor performance of several ductile reinforced concrete (RC) walls in the 2010-2011 Canterbury earthquakes was attributed to an increase in the levels of axial load that the walls sustained during the earthquakes. Among other reasons, it was proposed that that the magnification in the axial …

    auckland-ms Repository record for Wall-to-Floor Interaction in Reinforced Concrete Buildings (opens in a new tab)

  12. Experimental study of shape memory alloy connection in precast concrete shear walls for seismic applications

    … post-tensioned Precast Concrete (PC) shear walls are designed to rock around their base and self-center themselves upon unloading. One way to enhance ductility is by allowing controlled rocking at the wall-to-foundation connection using unbonded Post-tensioning (PT) tendons and mild steel …

    ubc Repository record for Experimental study of shape memory alloy connection in precast concrete shear walls for seismic applications (opens in a new tab) Download PDF for Experimental study of shape memory alloy connection in precast concrete shear walls for seismic applications (opens in a new tab)

  13. Numerical Analysis of Reinforced Masonry Shear Walls Using the Nonlinear Truss Approach

    Reinforced masonry (RM) shear walls are a common lateral load-resisting system for building structures. The seismic design guidelines for such systems are based on relatively limited experimental data. Given the restrictions imposed by the capabilities of available experimental equipment, …

    vt Repository record for Numerical Analysis of Reinforced Masonry Shear Walls Using the Nonlinear Truss Approach (opens in a new tab)

  14. Seismic Design of Lightly Reinforced Concrete Walls in Tall Buildings

    … Canterbury earthquakes highlighted that reinforced concrete (RC) walls designed with a low amount of vertical reinforcement are susceptible to sudden failure caused by strain concentration and reinforcement fracture at discrete cracks. Subsequent research resulted in amendment to the minimum …

    auckland-ms Repository record for Seismic Design of Lightly Reinforced Concrete Walls in Tall Buildings (opens in a new tab)

  15. Seismic Performance of Reinforced Concrete Walls Designed for Ductility

    … unexpected failure modes were observed in reinforced concrete (RC) structural walls, such as local buckling of longitudinal reinforcement, global buckling of the wall end section, and crushing of concrete at the wall end regions. In response to these observations, several amendments were made to …

    auckland-ms Repository record for Seismic Performance of Reinforced Concrete Walls Designed for Ductility (opens in a new tab)

  16. Inelastic Structural Response and FRP Retrofitting of Reinforced Concrete Core Walls

    The use of C-shaped reinforced concrete (RC) core walls as the main lateral force resisting system for building structures is a popular choice for medium- to high-rise buildings. These cores are typically closed on three sides (C-shaped) and are either open or partially open on the fourth side. …

    concordia Download PDF for Inelastic Structural Response and FRP Retrofitting of Reinforced Concrete Core Walls (opens in a new tab)

  17. Experimental and Analytical Investigation of Seismic Performance and Retrofit Techniques for Non-Ductile RC Structural Walls

    Reinforced concrete (RC) walls are widely used as lateral-force-resisting systems. Despite the interest in retrofitting techniques, critical knowledge gaps remain regarding the reliability and validity of current retrofit design guidelines and procedures, particularly for barbell walls with single …

    vt Repository record for Experimental and Analytical Investigation of Seismic Performance and Retrofit Techniques for Non-Ductile RC Structural Walls (opens in a new tab)

  18. Investigations on shear including the development of a material model for the FE analysis of cracked RC structures.

    … reports investigations on shear in cracked reinforced concrete (RC) elements including the development and implementation of a material subroutine for the commercial finite element (FE) program ABAQUS. The material subroutine UMAT is intended to substantially improve the shear behaviour of the …

    whiterose Download PDF for Investigations on shear including the development of a material model for the FE analysis of cracked RC structures. (opens in a new tab)

  19. Determination of stiffness reduction factor for U-shaped reinforced concrete shear walls under bi-axial loading

    <p>Reinforced Concrete (RC) shear wall, is an effective primary earthquake resisting system due to strong stiffness and large shear-force resisting capacity. For a complex asymmetric wall, severe damage on a portion of the wall may directly affect the stiffness in other directions. Such a secondary …

    iastate Repository record for Determination of stiffness reduction factor for U-shaped reinforced concrete shear walls under bi-axial loading (opens in a new tab)

  20. Seismic Performance Evaluation of Industrial and Nuclear Reinforced Concrete Shear Walls: Hybrid Simulation Tests and Data-Driven Models

    Low-aspect-ratio reinforced concrete (RC) shear walls, characterized by height-to-length ratios of less than two, have been widely used as a seismic force-resisting system (SFRS) in a wide array of structures, ranging from conventional buildings to critical infrastructure systems such as nuclear …

    mcmaster Repository record for Seismic Performance Evaluation of Industrial and Nuclear Reinforced Concrete Shear Walls: Hybrid Simulation Tests and Data-Driven Models (opens in a new tab)

Page 1 of 2