Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"RF coil design"”.

  1. Rf coil design for multi-frequency magnetic resonance imaging & spectroscopy

    … magnetic resonance (NMR) transmitter/receivers (coils) capable of operating at multiple frequencies, while maintaining a good performance at each frequency. The objective of this work is to discuss various design approaches used for second-nuclei RF (radio frequency) coils, and to analyze the …

    tamu Repository record for Rf coil design for multi-frequency magnetic resonance imaging & spectroscopy (opens in a new tab)

  2. RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI

    … by the following approaches: (i) Exploration of coil designs capable of imaging both proton (1H – 63.8 MHz at 1.5T) and fluorine (19F – 60.1 MHz at 1.5T) nuclei involved: 1. The novel use of microelectromechanical systems to switch a single transceive vest coil between the two nuclei was compared …

    whiterose Download PDF for RF Coil Design, Imaging Methods and Measurement of Ventilation with 19F C3F8 MRI (opens in a new tab)

  3. High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry

    … scan time and improving SNR and CNR: the design of RF coils optimized to detect MRI signals from the anatomy of interest, and the determination of MRI relaxation properties of the tissues being imaged (allowing optimization of imaging parameters to improve CNR between tissues). Work on the …

    byu Repository record for High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry (opens in a new tab) Download PDF for High-Resolution MRI for 3D Biomechanical Modeling: Signal Optimization Through RF Coil Design and MR Relaxometry (opens in a new tab)

  4. Determination Of Correlations Induced By The Sense And Grappa Pmri Models With An Application To Mri Rf Coil Design

    … by SENSE, a new cost function for optimizing the design of RF coil arrays has also been developed and implemented to generate more favorable magnetic fields for functional connectivity studies in specific brain regions. Images reconstructed with such arrays have an improved signal-to-noise ratio …

    marquette Repository record for Determination Of Correlations Induced By The Sense And Grappa Pmri Models With An Application To Mri Rf Coil Design (opens in a new tab)

  5. Measurement of the magnetic field of an RF-encoding birdcage-coil design for magnetic resonance imaging

    … depends on the use of magnetic field gradient coils to visualize tissue. However, there is an alternate method, which can only use RF to encode the image. The idea behind RF encoding is that it uses spatial phase variation in the RF transmission to encode spatial information in the MRI signal …

    sask Repository record for Measurement of the magnetic field of an RF-encoding birdcage-coil design for magnetic resonance imaging (opens in a new tab)

  6. Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI

    … each regime presents unique challenges in RF coil design, affecting imaging quality, patient safety, and system accessibility. This dissertation introduces a series of innovations in antenna structures, multi-channel array configurations, safety enhancement techniques, and material-based …

    buffalo Repository record for Advanced RF Hardware Solutions for Improved Imaging Performance and Safety in Ultra-High and Very-Low-Field MRI (opens in a new tab)

  7. RF and electronic design perspective on ultra-high field MRI systems

    … challenges: the fully automatic matched / tuned RF head coil design and RF coil design with improved B1 field uniformity. Both have been being considered as critical problems at ultra-high field (7T and beyond) MRI systems. The first study aims to build a real-time, high-speed, electrically …

    umn Repository record for RF and electronic design perspective on ultra-high field MRI systems (opens in a new tab)

  8. New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI

    … To achieve this, we developed new methods to design radiofrequency (RF) arrays optimized for these purposes. Our approach is to design an eight-channel array coil that is both transmit and receive, and could be used for both types of studies. We focused on optimizing the array for the …

    manitoba Repository record for New methods for optimizing parallel transmit/receive array coils to small field-of-view excitation for breast and cardiac MRI (opens in a new tab)

  9. CMDM Resonators and Dielectric Coated Dipole Antenna for Ultra-High Field MR Imaging: Field Efficiency and Safety Evaluations

    … mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high …

    buffalo Repository record for CMDM Resonators and Dielectric Coated Dipole Antenna for Ultra-High Field MR Imaging: Field Efficiency and Safety Evaluations (opens in a new tab)

  10. Echo Planar Spectroscopic Imaging and 31P In Vivo Spectroscopy

    … acquisitions there are problems surrounding RF coil design, pulse sequence speed, localization and system calibration. The work presented here focused on improving all these aspects and provide easy and reliable work flow to use <sup>31</sup>P MRS in a clinical setting.<br />One of the …

    mcmaster Repository record for Echo Planar Spectroscopic Imaging and 31P In Vivo Spectroscopy (opens in a new tab)

  11. The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging

    … this dissertation, a novel RF coil design, termed the wireless integrated parallel reception, excitation, and shimming (iPRES-W) coil design, is further developed to remove some of these wired connections by offering a compact and easy-to-integrate MR-compatible wireless data …

    duke Repository record for The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging (opens in a new tab)

  12. Strategies for Artifact Correction and Motion Monitoring in MRI Through Innovations in Radiofrequency Coil Design

    … strategies using innovations in radio-frequency (RF) coil design to address the problems that arise when these assumptions are broken. </p><p>Typically, B_0 inhomogeneities are caused by susceptibility differences at air/tissue interfaces and result in image artifacts such as geometric distortions …

    duke Repository record for Strategies for Artifact Correction and Motion Monitoring in MRI Through Innovations in Radiofrequency Coil Design (opens in a new tab)

  13. Simulation, Design, and Implementation of Approaches to RF-Encoded (TRASE) MRI

    Magnetic Resonance Imaging (MRI) has become a powerful medical imaging tool in the last four-five decades. Technological advancements in MRI have largely focused on increasing the field strength - to achieve higher signal to noise ratio (SNR) - but there is a strong motivation behind developing …

    sask Repository record for Simulation, Design, and Implementation of Approaches to RF-Encoded (TRASE) MRI (opens in a new tab)