Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 115 for “"RF field"”
-
Miniaturized Acousto-Optic Sensor for RF Field Measurement Under MRI
RF field measurement under MRI presents a significant measurement challenge. Both components of the RF field, the electric field and the magnetic field, are uniquely important for real-time sensing during an MR-sequence: the electric field contributes to deposited RF power in the tissue, leading to …
-
Analytical Path to Improved RF Field Homogeneity for High Field MRI
The focus of this dissertation is on the finite RF (radio frequency) wavelength effect in high field MRI (magnetic resonance imaging). As the RF frequency increases proportionally with the main magnetic field strength, and due to the high dielectric permittivity of human tissue, the wavelength of …
-
Heating mechanisms in rf-driven ultracold plasmas
… evolution. The introduction of a disturbing rf-field to the plasma is expected to speed up the heating of the plasma.In this thesis the intrinsic electron heating mechanisms are studied as well as the heating mechanisms induced by an external rf field. Numerical simulations were performed …
-
Microwave magnetic resonance and absorption in holmium single crystals
Field dependent microwave absorption has been observed in single crystal basal plane platelets of holmium in the range 35° K to 80° K. The rf field was aligned parallel to an easy "b" axis with the dc field at an angle of 0°, 30°, 60°, or 90° to the rf field. No sharp resonances were observed, nor …
-
Joule Heating of Carbon Fibers and their Composites in Radio Frequency Fields
… generate heat when exposed to radio frequency (RF) fields, but little is known about the relationship between material properties and the heating behavior. Our group has previously shown that this heating response can be used for the manufacturing of CF-reinforced composites. Here we analyze the …
-
Theory of Ultracold Atomic Collisions in Radio-frequency Fields
… static magnetic and oscillating radio-frequency (rf) fields. The bound state structure and scattering length of 39K+133Cs was examined in the presence of only a static magnetic field, where it was found that no Feshbach resonance of suitable width for magnetoassociation existed at a magnetic field …
-
Intracellular Hyperthermia Mediated by Nanoparticles in Radiofrequency Fields in the Treatment of Pancreatic Cancer
… cytotoxic effects of nonionizing radiofrequency fields in pancreatic cancer. Cancer cell death was induced by heat release from intracellular metal nanoparticles after radiofrequency field exposure. Fluorescent and gold nanoparticles were delivered with two antibodies, cetuximab and PAM-4, to …
-
Low frequency double electron Muon resonance in fused quartz
… and semiconductors. A DEMUR experiment was performed at a low rf frequency to investigate the response of the muonium coupled spin system to perpendicular static and oscillating fields of comparable magnitude. The experiment was performed in fused quartz with a linearly polarized rf field …
-
Multiple quantum magic-angle spinning NMR with cross-polarization: spectral editing of high-resolution spectra of half-integer quadrupolar nuclei
… for spectral editing. The radio-frequency (rf) pulse sequences and necessary phase-cycling are developed and examined. A novel approach of incorporating a 'z-filter' between the two techniques allowed us to optimize our new procedure, CP MQMAS, as two unique experiments prior to their …
-
The atomic waveplate
… outcoupled from an atom laser passing through an RF resonance. Within the Landau-Zener formalism, we find a range for the Rabi frequency of the RF field, inside of which dynamical spin transitions occur. We find that atoms exiting the resonance region exhibit symmetric transition into trapped and …
-
Modeling and Optimizing Multiple Quantum Magic Angle Spinning NMR Spectra in the Static Limit
… be applied for arbitrary excitation and mixing rf field strengths, pulse durations, and MAS rates within the static limit approximation.</p><p>Using this approach, we investigated the triple quantum excitation and mixing as a function of θ = ω<sub>1</sub> <i>t</i><sub>ex</sub> and θ = …
-
'ACOUSTO-OPTIC SENSING FOR SAFE MRI PROCEDURES'
… and by measuring the radio frequency (RF) field to assess RF safety of patients with implants, such as pacemakers, during diagnostic MRI. The sensor is based on an acousto-optic modulator coupled with a miniature antenna. This structure is realized on an optical fiber which is immune to …
-
Hybrid TEM-Reverberation chamber for Electromagnetic immunity testing
… of electromagnetic environments for radiated RF field immunity tests: a hybrid TEM-Reverberation chamber. The proposed chamber is a TEM cell with a reverberation chamber stirrer of special design installed between the septum and the shell (patent pending).
-
Theoretical studies of the VASIMR plasma propulsion concept
… plasma source, which creates cold plasma via rf-discharge; an ion cyclotron-resonance heating (ICRH) section, which is used to deposit rf-power into the plasma; and a magnetic nozzle, which forms highly directed superalfvenic outgoing plasma flow. The dissertation is focused on fundamental …
-
Ultra-low Frequency Electron Paramagnetic Resonance Based on Longitudinal Detection and Fictitious Field Modulation
… intensity is directly affected by the external field strength and the spin system properties. It is challenging to acquire signal from electron spins at ultra-low field because of their short relaxation times: the weak signal would decay away before it can be captured. The longitudinal detec- …
-
Thermal Feedback in Coaxial Superconducting RF Cavities
Superconducting RF (SRF) cavities are used in particle accelerators to efficiently transfer energy from an RF power source to a beam of charged particles. The power losses associated with this process are inversely proportional to the cavity quality factor Q0, which decreases with increasing RF …
-
Diagnostics and modelling of an inductively coupled RF low-pressure low-temperature plasma
… in the experimental work. Given fixed external RF coil current and voltage and the measured plasma density profile, Maxwell's equations and magnetohydrodynamical (MHD) fluid equations are used to calculate the self-consistent electromagnetic field. A number of predictions are presented and …
-
Construction of a low temperature nuclear magnetic resonance force microscope
… a nuclear magnetic resonance force microscope (NMRFM) have been constructed. The development and testing of each aspect area are discussed in detail. In particular, two sets of three-axis piezoelectric positioners based on a stick-slip motion have been successfully incorporated and tested for a …
-
Some novel developments in high-resolution NMR spectroscopy
The radiofrequency (rf) pulses used in NMR are subject to a number of imperfections, such as those resulting from the inhomogeneity of the rf field or an offset of the transmitter frequency from exact resonance. In spin-echo experiments, these imperfections yield spectra with reduced signal …
Page 1 of 6