Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"RF safety"”.
-
Developing RF safety strategies at high field and ultra-high field MRI
Radiofrequency (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for …
-
Developing RF safety strategies at high field and ultra-high field MRI
Radiofrequency (RF) safety remains a critical concern in high field and ultra-high field magnetic resonance imaging (MRI), especially for patients with implanted medical devices such as deep brain stimulation (DBS) systems. This thesis addresses two central aims which are improving RF safety for …
-
Methods to Evaluate and Increase the RF Safety of Cardiovascular Interventional Devices During MRI
… MRI guidance is currently contraindicated due to RF safety concerns. The success rate of such procedures could be improved by devices designed to exploit the unique features of MRI. Unfortunately such devices require long linear conductive structures, which present a significant risk to the …
-
A Transmission Line Model for Active Implantable Medical Devices under MRI
… implantable medical devices (AIMDs) due to safety concerns. In the United States alone, there are millions of people having AIMDs and a significant number of them need follow-up MRI scanning during their lifetimes. Some of the major MRI safety concerns come from the interaction between the …
-
Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety
… increased inhomogeneity in the radio frequency (RF) fields required to create MR signals and greater RF energy deposition – known as the specific absorption rate (SAR) – within imaging subjects. These factors have prompted the use of parallel transmission (PTx) MRI; in which multiple independent …
-
Application of Phase Imaging at High Field - MR Thermometry at 7 Tesla
… research was to develop improved methods for RF coil characterisation, and for non-invasive spatio-temporal mapping of temperature in the living body, in order to utilise the full potential of magnetic resonance imaging (MRI) at high magnetic fields by ensuring radiofrequency (RF) safety. …
-
Radiofrequency safety modelling of parallel transmit magnetic resonance imaging
<p>Radio-frequency (RF) safety plays an important role in Magnetic Resonance Imaging (MRI) with the goal of assuring patient safety and preventing excessive RF heating. Historically, RF safety in MRI has been monitored using pre-calculated specific absorption rate (SAR) limits which indicate the …
-
MRI Safety Concerns: Anatomy Impacts on Radiofrequency Induced Heating and Implant Impacts on Gradient Induced Peripheral Nerve Stimulation
… is a very useful technology but there are some safety concerns for patients. Radiofrequency (RF) induced heating and gradient induced peripheral nerve stimulation (PNS) are two typical safety concerns. Although many literatures have found the importance of them, they are not fully investigated. …
-
Noninvasive microwave technique for human cardiorespiratory hemodynamic assessments
… of the proposed approach. The radiation bio-safety aspect of this approach was evaluated using a DASY4 near-field scanner, often used for certifying cell phones. Obtained results for a 30mW input power show that the Specific Absorption Rate (SAR) values are about one third of the FCC RF …
-
MRI Safety Evaluation of Dual Leads and Fractured Leads Active Implantable Medical Devices in MRI
Magnetic resonance imaging (MRI) radiofrequency (RF)-induced heating is of great concern for patients with active implantable medical devices (AIMDs) undergo MR scanning. RF safety evaluation of AIMDs consists of two steps: (1) the development of the AIMD model (i.e., transfer function (TF) …
-
'ACOUSTO-OPTIC SENSING FOR SAFE MRI PROCEDURES'
… and by measuring the radio frequency (RF) field to assess RF safety of patients with implants, such as pacemakers, during diagnostic MRI. The sensor is based on an acousto-optic modulator coupled with a miniature antenna. This structure is realized on an optical fiber which is immune to …
-
ENABLING INTERVENTIONAL MRI USING AN ULTRA-HIGH FIELD LOOPLESS ANTENNA
… durations. This dissertation investigates the performance of the interventional loopless antenna at UHF and introduces new methods to enable UHF iMRI using interventional loopless antennae. First, a new MRI denoising method based on a spectral subtraction technique that can provide up to 45% of …