  1. Radiator modeling and design for MRI safety assessment

    … imagine. Although 1.5T MRI is still the most performed procedure in clinic, higher fields such as 3 T and 7 T are gaining more popularity because of their increased sensitivity and spatial resolution. However, the increased frequency caused the degradation of the field uniformity. To compensate …

    houston Repository record for Radiator modeling and design for MRI safety assessment (opens in a new tab)

  2. Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging

    … and increased robustness against field imperfections are demonstrated by phantom and in-vivo brain studies at 7T. Second, the use of a variety of radiofrequency management methods with parallel transmission is explored in the human torso for the first time at 10.5T. Preliminary high quality …

    umn Repository record for Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging (opens in a new tab)

  3. Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety

    … increased inhomogeneity in the radio frequency (RF) fields required to create MR signals and greater RF energy deposition – known as the specific absorption rate (SAR) – within imaging subjects. These factors have prompted the use of parallel transmission (PTx) MRI; in which multiple independent …

    kings Repository record for Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety (opens in a new tab) Download PDF for Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety (opens in a new tab)

  4. Development of technologies to enable clinical 7T body MRI

    … torso is multiple times larger than this, EM interference patterns are prevalent and require careful management. The first issue related to these interference patterns is spatially varying B1+ which results in variable excitation profiles; leading to images with variable contrast and signal …

    umn Repository record for Development of technologies to enable clinical 7T body MRI (opens in a new tab)

  5. Construction and characterisation of MRI coils for vessel wall imaging at 7 tesla

    … together with an appropriate and patient-safe RF coil, will result in higher resolution images that would help in better assessing the composition of atherosclerotic plaques in vessel walls. A custom-built neck array was designed and constructed, with the aim of investigating the benefits of …

    oxford Repository record for Construction and characterisation of MRI coils for vessel wall imaging at 7 tesla (opens in a new tab)

  6. Highly Accelerated Myocardial Perfusion Magnetic Resonance Imaging

    Introduction<br/>First-pass myocardial perfusion cardiovascular magnetic resonance imaging (CMR) has<br/>become an established method for the non-invasive diagnosis of ischaemic heart disease<br/>(IHD). As complete datasets are acquired every heart beat, first-pass perfusion CMR is<br/>challenging, …

    kings Repository record for Highly Accelerated Myocardial Perfusion Magnetic Resonance Imaging (opens in a new tab) Download PDF for Highly Accelerated Myocardial Perfusion Magnetic Resonance Imaging (opens in a new tab)