Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 8 of 8 for “"RF-shimming"”

  1. Radiator modeling and design for MRI safety assessment

    … imagine. Although 1.5T MRI is still the most performed procedure in clinic, higher fields such as 3 T and 7 T are gaining more popularity because of their increased sensitivity and spatial resolution. However, the increased frequency caused the degradation of the field uniformity. To compensate …

    houston Repository record for Radiator modeling and design for MRI safety assessment (opens in a new tab)

  2. Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging

    … and increased robustness against field imperfections are demonstrated by phantom and in-vivo brain studies at 7T. Second, the use of a variety of radiofrequency management methods with parallel transmission is explored in the human torso for the first time at 10.5T. Preliminary high quality …

    umn Repository record for Application of Parallel Transmission to Ultra-High Field Magnetic Resonance Spectroscopy and Imaging (opens in a new tab)

  3. Advances in image acquisition and filtering for MRI neuroimaging at 7 tesla

    Performing magnetic resonance imaging at high magnetic field strength promises many improvements over low fields that are of direct benefit in functional neuroimaging. This includes the possibility of improved signal-to-noise levels, and increased BOLD functional contrast and spatial specificity. …

    uwo Repository record for Advances in image acquisition and filtering for MRI neuroimaging at 7 tesla (opens in a new tab)

  4. Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety

    … increased inhomogeneity in the radio frequency (RF) fields required to create MR signals and greater RF energy deposition – known as the specific absorption rate (SAR) – within imaging subjects. These factors have prompted the use of parallel transmission (PTx) MRI; in which multiple independent …

    kings Repository record for Parallel Transmission MRI for Optimised Cardiac Imaging and Improved Safety (opens in a new tab)

  5. Development of technologies to enable clinical 7T body MRI

    … torso is multiple times larger than this, EM interference patterns are prevalent and require careful management. The first issue related to these interference patterns is spatially varying B1+ which results in variable excitation profiles; leading to images with variable contrast and signal …

    umn Repository record for Development of technologies to enable clinical 7T body MRI (opens in a new tab)

  6. Construction and characterisation of MRI coils for vessel wall imaging at 7 tesla

    … together with an appropriate and patient-safe RF coil, will result in higher resolution images that would help in better assessing the composition of atherosclerotic plaques in vessel walls. A custom-built neck array was designed and constructed, with the aim of investigating the benefits of …

    oxford Repository record for Construction and characterisation of MRI coils for vessel wall imaging at 7 tesla (opens in a new tab)

  7. Highly Accelerated Myocardial Perfusion Magnetic Resonance Imaging

    Introduction<br/>First-pass myocardial perfusion cardiovascular magnetic resonance imaging (CMR) has<br/>become an established method for the non-invasive diagnosis of ischaemic heart disease<br/>(IHD). As complete datasets are acquired every heart beat, first-pass perfusion CMR is<br/>challenging, …

    kings Repository record for Highly Accelerated Myocardial Perfusion Magnetic Resonance Imaging (opens in a new tab)

  8. B1+-mapping and B1+ inhomogeneity correction at high field

    … is subject to constructive and destructive interferences and becomes position dependent. This inhomogeneity in the B1+ field leads to signal and contrast variations in the anatomical images which are prone to misinterpretation. This thesis is about measuring and correcting the inhomogeneous B1+ …

    epfl Repository record for B1+-mapping and B1+ inhomogeneity correction at high field (opens in a new tab)