Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 70 for “"RFQ"”.

  1. A cw 4-rod RFQ Linac

    kyoto Repository record for A cw 4-rod RFQ Linac (opens in a new tab)

  2. The buffer-gas cell and the extraction RFQ for SHIPTRAP

    … to separate the ions from the buffer gas, an RFQ buncher to cool and accumulate the ions and a tandem Penning-trap system for isobaric purification and high-precision mass measurements. The buffer-gas cell and the extraction RFQ were developed, assembled and tested within this thesis at the …

    lmu-germany Repository record for The buffer-gas cell and the extraction RFQ for SHIPTRAP (opens in a new tab)

  3. Electronic Population Manipulation in an RFQ Ion Trap for the Study of Rare Transition Metal Isotopes

    … on ions in a Radio-Frequency Quadrupole(RFQ) cooler/buncher ion trap. The commissioning experiments were performed with a beam of stable Zr+, produced by an oine plasma discharge sputter ion source and delivered to the BECOLA RFQ ion trap. Two optical pumping schemes were investigated, …

    msu Repository record for Electronic Population Manipulation in an RFQ Ion Trap for the Study of Rare Transition Metal Isotopes (opens in a new tab)

  4. Validade do Questionário de Função Reflexiva (RFQ) para avaliar mentalização em adultos da população geral, em pacientes com TDAH e em psicoterapia de orientação analítica

    … aferida pelo questionário de função reflexiva (RFQ), porém recentes análises estão encontrando problemas no instrumento, indicando que a RFQ-8 avalia apenas a incerteza em relação aos estados mentais. Neste trabalho, testamos a validade de constructo do questionário de função reflexiva (RFQ) nas …

    brazil-ufrgs Repository record for Validade do Questionário de Função Reflexiva (RFQ) para avaliar mentalização em adultos da população geral, em pacientes com TDAH e em psicoterapia de orientação analítica (opens in a new tab)

  5. Development of RF accelerating structures in the front-end system of light ion particle accelerators

    … reliability of the radio frequency quadrupole (RFQ) and the rebuncher cavities in the low beam energy front-end section of the SNS accelerators, have been improved by applying our newly proposed design ideas. In this dissertation, we propose four development directions for RFQ and rebuncher …

    utk-theses Repository record for Development of RF accelerating structures in the front-end system of light ion particle accelerators (opens in a new tab)

  6. Study of the impact of operational conditions on radio frequency quadrupole material properties

    … integrity of Radio-Frequency Quadrupoles (RFQs), with emphasis on radiation-induced degradation mechanisms in structural Cu-OFE copper. This project is focused on the ESS RFQ conditioning and commissioning, microstructural Cu-OFE copper characterization, advanced non-destructive …

    greece Repository record for Study of the impact of operational conditions on radio frequency quadrupole material properties (opens in a new tab)

  7. Η σχέση της αυτοκτονικότητας με την αναστοχαστική ικανότητα (mentalization) σε ασθενείς με μείζονα καταθλιπτική διαταραχή

    … κλίμακες Reflective Functioning Questionnaire (RFQ), Beck Depression Inventory (BDI-2) and Suicidal Behaviors Questionnaire-Revised (SBQ-R) για την εκτίμηση της ικανότητας αναστοχασμού, της καταθλιπτικής συμπτωματολογίας και της αυτοκτονικότητας αντίστοιχα. Οι βαθμολογίες της RFQ δεν προέβλεπαν …

    athens Repository record for Η σχέση της αυτοκτονικότητας με την αναστοχαστική ικανότητα (mentalization) σε ασθενείς με μείζονα καταθλιπτική διαταραχή (opens in a new tab)

  8. A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN

    … gas-filled, RadioFrequency Quadrupole (RFQ). Such a device has been developed for use in the TITAN experiment. Previous RFQ coolers have been driven sinusoidally, however this device will be driven with a large amplitude (V[sub pp] = 400 V) high frequency (f = 1 MHz) square-wave. This …

    ubc Repository record for A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN (opens in a new tab) Download PDF for A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN (opens in a new tab)

  9. Influence of Aminocyclopyrachlor plus Metsulfuron on Seedhead Development and Forage Quality in Tall Fescue

    … crude protein (CP) and relative forage quality (RFQ).</p> <p>This research also determined the impact of ACP plus MET application timing and rate on tall fescue injury and weed control. Spring and early fall applications generally resulted in the greatest tall fescue discoloration and stunting …

    utk-theses Repository record for Influence of Aminocyclopyrachlor plus Metsulfuron on Seedhead Development and Forage Quality in Tall Fescue (opens in a new tab)

  10. Structural Characterization of Metal Binding in Metallo-β-Lactamases Using X-Ray Absorption Spectroscopy

    … Stenotrophomonas maltophilia was explored with RFQ (rapid-freeze quenched) EXAFS and site selective metal substitution. RFQ EXAFS show the metal coordination at 10 ms in the reaction in the native enzyme including a zinc-zinc distance (3.72Å) greater than is present in either the resting or …

    unm Repository record for Structural Characterization of Metal Binding in Metallo-β-Lactamases Using X-Ray Absorption Spectroscopy (opens in a new tab)

  11. A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometer

    … square-wave-driven Radio- Frequency Quadrupole (RFQ) ion guide, which was filled with hydrogen gas. The cooled ion bunches were then passed into a Penning trap where the mass measurements were made. A description of the RFQ in the ISAC hall is given along with some results from the commissioning …

    ubc Repository record for A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometer (opens in a new tab) Download PDF for A mass measurement of the short-lived halo nucleus ¹¹Li with the TITAN Penning trap spectrometer (opens in a new tab)

  12. Installation and Testing of the Isobar Separator for Anions at the A. E. Lalonde AMS Laboratory Using Chlorine-36 Analysis

    … for Anions (ISA) is a radiofrequency quadrupole (RFQ) reaction cell system that provides selective isobar suppression for many of these isotopes in the low energy system, prior to injection into an accelerator. The ISA can then facilitate the measurement of these ions using smaller accelerators. A …

    ottawa-retro Repository record for Installation and Testing of the Isobar Separator for Anions at the A. E. Lalonde AMS Laboratory Using Chlorine-36 Analysis (opens in a new tab)

  13. Design and commissioning of a 16.1 MHz multiharmonic buncher for the reaccelerator at NSCL

    … certain classes of experiments. The cavities and RFQ used in ReA have an operating frequency of 80.5 MHz, which corresponds to a separation between particle bunches at the detectors of 12.4 ns. While this separation is acceptable for many experiments, sensitive time of flight measurements require …

    msu Repository record for Design and commissioning of a 16.1 MHz multiharmonic buncher for the reaccelerator at NSCL (opens in a new tab)

  14. Development of the TAMUTRAP Facility for Precision Beta-Decay Studies

    … other facility. A Radio Frequency Quadrupole (RFQ) Paul trap cooler and buncher will be used to prepare ions for loading into the Penning trap system. This thesis will cover the design and development of the Penning and Paul traps in addition to numerous ancillary components, such as …

    tamu Repository record for Development of the TAMUTRAP Facility for Precision Beta-Decay Studies (opens in a new tab)

  15. Vstupní data nákupního procesu

    … procesu výpočtu vstupních dat pro proces RFQ & Awarding v oddělení projektového nákupu. Prostřednictvím analýzy a simulace stávajících variant procesu identifikuje rizika, úzká místa a jejich příčiny. Na základě těchto zjištění navrhuje úpravy procesu vedoucí ke snížení rizik a integraci …

    brno-tech Repository record for Vstupní data nákupního procesu (opens in a new tab)

  16. Αναπαράσταση του εαυτού και χρόνιος σπονδυλικός πόνος. Διερεύνηση της σχέσης των γνωστικών σχημάτων για τον εαυτό και των υποκειμενικών αντιλήψεων ταύτισης με τον πόνο με ψυχοκοινωνικές συνιστώσες και με τα επίπεδα πόνου και ανικανότητας σε άτομα με χρόνιο μυοσκελετικό σπονδυλικό πόνο

    … (CD-RISK) και την αναστοχαστική ικανότητα (RFQ). Το δείγμα της έρευνας (Ν=20), αποτελούνταν από άτομα με χρόνιο σπονδυλικό πόνο (ΑΜΣΣ, ΘΜΣΣ, ΟΜΣΣ), η ηλικία των οποίων κυμαινόταν από τα 26 ως και τα 70 έτη. Οι συμμετέχοντες διαχωρίστηκαν σε 2 ομάδες με βάση τα αποτελέσματα τους στο εργαλείο …

    athens Repository record for Αναπαράσταση του εαυτού και χρόνιος σπονδυλικός πόνος. Διερεύνηση της σχέσης των γνωστικών σχημάτων για τον εαυτό και των υποκειμενικών αντιλήψεων ταύτισης με τον πόνο με ψυχοκοινωνικές συνιστώσες και με τα επίπεδα πόνου και ανικανότητας σε άτομα με χρόνιο μυοσκελετικό σπονδυλικό πόνο (opens in a new tab)

Page 1 of 4