Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 82 for “"RMF"”.
-
Μικροδοσιμετρικά μοντέλα υπολογισμού του RBE στην αδρονιακή θεραπεία με έμφαση στο μοντέλο RMF / Microdosimetric models for RBE calculation in hadron therapy: focus on the RMF model
… χρησιμοποιώντας το ραδιοβιολογικό μοντέλο RMF, και εξετάζεται η απόδοση συγκρίνοντας με ραδιοβιολογική βάση δεδομένων. Αρχικά κατασκευάζονται καμπύλες δόσης-βάθους για πρωτόνια με την αναλυτική μέθοδο του Bortfeld. Η μέθοδος αυτή στηρίζεται στην σχέση R = aE^p, η οποία δίνει την εμβέλεια ως …
-
Buccal Bone Changes Following Rapid Maxillary Expansion (RMF), Long-Term Results
The purpose of this study was to use Cone Beam Computed Tomography (CBCT) images to quantitatively evaluate buccal bone changes of maxillary first premolar (P1), second premolar (P2) and first molar (M1) shortly after Rapid Maxillary Expansion (RME) and at the end of orthodontic treatment, as well …
-
QUANTIFYING THE RISK MANAGEMENT FRAMEWORK
… While the current Risk Management Framework (RMF) approach improves upon its predecessors, it is once again in need of an overhaul. Derived from National Institute of Standards and Technology (NIST) and DOD directives, the DON’s RMF process blindly inherited the ambiguity necessary for larger …
-
Effects of respiratory muscle fatigue on exercise performance in healthy females
… demonstrated that respiratory muscle fatigue (RMF) occurs following high-intensity exercise as well as prolonged submaximal exercise. In order to investigate RMF as a limiting factor in exercise performance fatigue was induced in ten healthy female participants (Age = 26.8 ± 2.0 yrs; height = …
-
EVOLVING THE RISK MANAGEMENT FRAMEWORK TO ENHANCE DEPARTMENT OF DEFENSE CYBERSECURITY
… achieve through the Risk Management Framework (RMF) assessment requirements established by the National Institute of Standards and Technology (NIST). Despite its significance to improving standardization and security across the DoD, the current RMF process contains subjectivity, inefficiency, …
-
The star thrust experiment, rotating magnetic field current drive in the field reversed configuration
… (FRC) with a Rotating Magnetic Field (RMF) operated at a strength of 25 G and a frequency of 350 kHz. The RMF was generated with two IGBT switched solid state power supplies capable of delivering 2 MW each. Plasmas were typically 2 m long by 0.2m in radius and consisted of fully ionized …
-
WAVES IN PLASMAS GENERATED BY A ROTATING MAGNETIC FIELD AND IMPLICATIONS TO RADIATION BELTS
The interaction of rotating magnetic fields (RMF) with magnetized plasmas is a fundamental plasma physics problem with implications to a wide range of areas, including laboratory and space plasma physics. Despite the importance of the topic the basic physics of the phenomenon remains unexplored. An …
-
Beeinflussung des Wärme- und Stofftransports bei der Vertical Gradient Freeze-Kristallzüchtung durch ein rotierendes Magnetfeld
… der Schmelze durch ein rotierendes Magnetfeld (RMF) untersucht. An GaAs- und Ge-Kristallen konnte bei Einwirkung des RMF eine verminderte Durchbiegung der Phasengrenze aufgrund geringerer radialer Temperaturgradienten festgestellt werden. Die Analyse der Segregationsprozesse ergab unter …
-
Optimizing fMRI analysis in Schizophrenia research: methodology improvements
La Resonancia Magnética funcional (RMf) es una técnica moderna de neuroimagen que permite la localización de actividad neuronal con una alta resolución espacial. La técnica de RMf emplea los cambios locales de oxigenación en la sangre, reflejados como pequeños cambios en la intensidad en un tipo …
-
Investigation of the Three-Dimensional Structure of a Rotating Magnetic Field Driven Field-Reversed Configuration using Internal Magnetic Field Measurements
… device (TCSU) used a rotating magnetic field (RMF) to form and sustain plasma in a field-reversed configuration (FRC). The physics of RMF current drive can be modeled in terms of the torque acting on the FRC. A fully translatable three-axis internal magnetic probe was built and used to generate …
-
Application of rotating magnetic fields to the travelling heater method growth of GaSb and the synthesis of CdTe
… is the application of a rotating magnetic field (RMF) in the plane perpendicular to the growth direction, which induces two magnetic body force components; one in the radial direction and the other one in the circumferential direction. These two body force components alter the fluid flow in the …
-
Study of finite-size exponential firing neural networks in the replica-mean-field limit
… in the recently proposed replica-mean-field (RMF) limit. In this limit, networks are made of infinitely many replicas of the original finite-size networks with randomized interactions across replicas. Such limit has rendered certain excitatory networks fully tractable with explicit dependence …
-
Design of rotating magnetic field current drive and magnetic confinement system for Q-REX
… evaluation of the Q-REX rotating magnetic field (RMF) plasma device. The primary objective of Q-REX is to investigate compact, low-cost approaches to forming and sustaining field-reversed configurations (FRCs) using digitally controlled power electronics. To support this goal, a 12 kW, 365 kHz …
-
Managing inter-organisational relationships among project parties in large and complex construction projects
… a prototype Relationship Management Framework (RMF) was developed. It was then validated and refined by means of four Key Informant Interviews (KIIs) with senior construction experts. The resulting final RMF was then tested and its performance was evaluated by means of application to a …
-
Θεωρητική μελέτη ιδιοτήτων εξωτικών πυρηνών στα πλαίσια της σχετικιστικής θεωρίας μέσου πεδίου
… This theory is based on Relativistic Mean Field (RMF) model. In this thesis a new parametrization for the Langrangian of the RMF model is proposed. The new force, which is named NL3*, improves the description of the ground state properties of all nuclei at and away from stability line and …
-
Rotating magnetic field technology for flaw detection in gas pipe lines
… that the circumferential component of the RMF is sensitive to axially oriented defects in pipe-walls. The model results were validated using the experimental measurements. Experiments were conducted by placing a 3-phase rotor inside a pipe and measuring the circumferential component of the …
-
Paramagnetic spin-up of a field reversed configuration with rotating magnetic field current drive
A transverse Rotating Magnetic Field (RMF) can drive toroidal current and sustain the poloidal flux of a Field Reversed Configuration (FRC) through the application of a 〈vz x Br〉 Lorentz force on the electrons, where vz is the axial screening current and Br is the radial component of the RMF. The …
-
Quantifying Uncertainty In A Measurement-Based Assessment of Relative Biological Effectiveness In Carbon Ion Radiotherapy
… Model (MKM), Repair Misrepair Fixation model (RMF), and Local Effect Model I (LEM) using a Tissue Equivalent Proportional Counter (TEPC). Microdosimetric spectra, kinetic energy spectra, and dose fragment contributions were calculated using Monte Carlo (GEANT IV) for monoenergetic and SOBP …
-
Four weeks of controlled frequency breathing training reduces respiratory muscle fatigue in elite college swimmers.
… training on reducing respiratory muscle fatigue (RMF). Elite swimmers (n = 25) were divided into either the CFB or a group that breathed regularly, every ~3rd stroke. The training intervention included 16 sessions of 12x50-m repetitions with either breathing pattern. RMF was defined as the drop in …
-
MAINTAINING A COMPETITIVE ADVANTAGE: AN ANALYSIS OF THE EFFICIENCY AND EFFECTIVENESS OF THE MARINE CORPS' ASSESSMENT AND AUTHORIZATION PROCESS
… to this effort is the Risk Management Framework (RMF), the mandated process by which we assess and mitigate cybersecurity risks to these systems in the rapidly evolving threat environment. To maintain its effectiveness, the Marine Corps must continue to make process improvements that support the …
Page 1 of 5