Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 21 for “"RSSCT"”
-
Evaluating Physical and Chemical Properties of Ground Anion Exchange (AEX) Resin for the Design of Rapid Small-Scale Column Tests (RSSCTs)
… variables in the rapid small-scale column test (RSSCT) scaling equations derived from the dispersed-flow, pore and surface diffusion model (DFPSDM). Compared to the bulk resin, there were major differences (>10%) in AEC on a packed bed basis (Qb) for both resins, and in bed porosity for PFA694E. …
-
Competitive Adsorption of Iron and Natural Organic Matter in Groundwater Using Granular Activated Carbon
… evaluation of the rapid small-scale column test (RSSCT) for predicting the full-scale GAC column breakthroughs. The characterization of Vars groundwater showed that ferrous iron was found to be the dominant iron species, representing 90% of the total iron, and that 15 - 35% of the iron was …
-
Removal of Arsenic from Contaminated Water by Granular Activated Carbon Embedded with Nano scale Zero-valent Iron
… the batch and Rapid Small Scale Column Test (RSSCT). The adsorption depends on pH, initial concentration, and reaction time. Arsenite adsorption capacity varies from 800 to 1400 μg/g over the pH 2-11. Arsenate adsorption was higher (3000-3700 μg/g) over the acidic pH range 2-6.5. Among …
-
Removal of Arsenic from Contaminated Water by Granular Activated Carbon Embedded with Nano scale Zero-valent Iron.
… the batch and Rapid Small Scale Column Test (RSSCT). The adsorption depends on pH, initial concentration, and reaction time. Arsenite adsorption capacity varies from 800 to 1400 μg/g over the pH 2-11. Arsenate adsorption was higher (3000-3700 μg/g) over the acidic pH range 2-6.5. Among …
-
Removal of Arsenic from Contaminated Water by Granular Activated Carbon Embedded with Nano scale Zero-valent Iron.
… the batch and Rapid Small Scale Column Test (RSSCT). The adsorption depends on pH, initial concentration, and reaction time. Arsenite adsorption capacity varies from 800 to 1400 μg/g over the pH 2-11. Arsenate adsorption was higher (3000-3700 μg/g) over the acidic pH range 2-6.5. Among …
-
Removal of Arsenic from Contaminated Water by Granular Activated Carbon Embedded with Nano scale Zero-valent Iron.
… the batch and Rapid Small Scale Column Test (RSSCT). The adsorption depends on pH, initial concentration, and reaction time. Arsenite adsorption capacity varies from 800 to 1400 μg/g over the pH 2-11. Arsenate adsorption was higher (3000-3700 μg/g) over the acidic pH range 2-6.5. Among …
-
THM Precursor Removal in the Rapid Small-Scale Column Test
… and money, the rapid small-scale column test (RSSCT) was recommended as a bench-scale method to collect the data for the activated carbon alternative. The objective of this thesis was to assemble the RSSCT and test the procedure for the removal of organics from a blended surface and ground …
-
Comparative evaluation of six different granular activated carbon for TCP removal using rapid small scale column test
… Diffusivity-Rapid Small-Scale Column Test (CD-RSSCT) was performed to estimate the Granular Activated Carbon (GAC) usage rates of six different activated carbons for 1,2,3-Trichloropropane (TCP) removal. TCP is a synthetic chemical compound contained in industrial solvents and soil fumigants …
-
Graphene Oxide Assisted Hydrothermal Carbonization of Corn Fibre for High-Quality Activated Carbon and its Application for Water Purification using Rapid Small-Scale Column Testing
… using the rapid small-scale column testing (RSSCT) approach.
-
Advanced physicochemical processes for wastewater treatment: from combined sewer overflows to micropollutant removal
… validation of Rapid Small-Scale Column Tests (RSSCTs) for predicting Granular Activated Carbon (GAC) performance.Initially, a novel process combining 1 µm filtration with sequential ion exchange was designed, utilizing molecular sieve MS13X for cation exchange and Sorbacid 911 for anion …
-
Evaluation of hybrid treatment configurations of granular activated carbon and alternative adsorbents for per- and polyfluoroalkyl substances removal from surface water and groundwater
… waters. A rapid small-scale column test (RSSCT) system was used to assess the performance of Filtrasorb 400 (GAC), Fluoro-Sorb® 200 (FS), and CalRes2301 (IX) with three different source waters: PFAS spiked tap water, stormwater; and brackish groundwater. Additionally, this study evaluated …
-
Removal of Microcystin-LR from Drinking Water Using Granular Activated Carbon
… isotherms and rapid small scale column test (RSSCT) breakthrough curves for a variety of GAC products under different matrix conditions. Equilibrium isotherms were developed for six different GAC products from four different carbon source materials (hardwood, lignite, bituminous coal and …
-
Effects of Chemical Properties of Cyanotoxins on Transport through Granular Activated Carbons
… with the use of Rapid Small Scale Column Test (RSSCT). However, only a small number of studies focused on the use of reactivated GAC and assessed whether the chemical properties of cyanotoxins had an influence on the course of adsorption. This study aims to evaluate the effects of chemical …
-
AN INVESTIGATION OF SUSTAINABLE FLUORIDE WATER TREATMENT TECHNOLOGIES WITH A FOCUS ON ETHIOPIA
… validity of the Rapid Small Scale Column Tests (RSSCT) principles for bone char adsorbing fluoride from water. These experiments indicated that RSSCT principles are applicable for bone char; use of this approach can result in large time and cost savings to researchers and implementers. Overall, …
-
Ozone and biological activated carbon pretreatment for the enhanced removal of perfluoroalkyl acids from wastewater effluent by granular activated carbon
… and GAC rapid small scale column testing (RSSCTs) with wastewater effluent after different levels of pretreatment including no pretreatment, ozonation, BAC, and combined O3-BAC. A review of the literature determined that GAC treatment capacity is considerably reduced when wastewater is …
-
Impact Of Resin Grinding On Per- And Polyfluoroalkyl Substance Adsorption In Rapid Small-Scale Column Tests
… Rapid Small-Scale Column Tests (RSSCTs) offer a practical alternative, yet most studies have focused on granular activated carbon, with limited insight into ion exchange (IX) resins. Due to limited literature on the effect resin preparation on the performance of RSSCTs and their …
-
The Implications of Nanoparticles on the Removal of Volatile Organic Compounds from Drinking Water by Activated Carbon
… of 5 mg/L HA. Rapid small-scale column test (RSSCT) was assessed for its ability to predict TCE adsorption in pilot-scale GAC in the presence and absence of NPs. Measurements of zeta potential, the pH of point zero charge (pHpzc) and the particle size distribution of the three types of NPs …
-
Granular Activated Carbon (GAC) Adsorption of Per- and Poly- fluoroalkylSubstances (PFAS) from Drinking Water: Adsorption Kinetics, Capacity andImpacts of GAC, PFAS and Source Water Characteristics
… explored with rapid small-scale column test (RSSCT) simulations using Adsorption Design Software under different scaling conditions.Lastly, multi-solute (nine PFAS) isotherms were conducted with F400 in buffered Type 1 water, and with controlled variations of matrix conditions, evaluating …
-
Using Rapid Small Scale Column Testing to Evaluate Granular Activated Carbon Adsorption of Cyanotoxins from Drinking Water
… a bloom event. Rapid Small Scale Column Tests (RSSCTs) were used to simulate full scale GAC processes by applying the proportional diffusivity (PD) design. NOM, measured by TOC and UV254, and MC-LR, measured by LC/MS/MS, were monitored before and after the GAC PD-RSSCTs. Initial experiments …
-
STUDY ON TREATMENT TECHNOLOGIES FOR PERFLUOROCHEMICALS IN WASTEWATER
… all PFCs among the commercial GACs. Preliminary RSSCT and SBA results implied that background organics broke through fixed GAC bed much earlier than trace level of PFCs. Medium-chained PFCs can be effectively removed by fixed bed filtration without concerning biological processes. Direct …
Page 1 of 2