Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"Radar receiving apparatus"”.
-
A Two-Step Procedure for Radar Target Identification Using Correlated Sequential Detection
… of the importance of target identification by radar rneansz considerable data on radar scattering exists and there are many approaches to the identification problem that can be found in the open literature. The purpose of this study is to determine those characteristics of a radar target which …
-
Removal of interference inherent in the lens radar system
The NASA GSFC/Wallops Flight Facility focused radar system employed a large (43 cm diameter) dielectric focusing lens such that the water surface (target) was illuminated by a small radar spot (~1.25 cm diameter). With this small spot size, surface profiles and probability density functions could …
-
A multiple polarization plane ZDR radar data acquisition system
… thesis discusses the development of an S-band radar used to measure differential reflectivity in multiple polarization planes. The radar uses a novel polarization switch which allows reflectivity measurements in any linear polarization. A dedicated microcomputer and a digital hardware system …
-
Design of multiple frequency continuous wave radar hardware and micro-Doppler based detection and classification algorithms
… of a multiple frequency continuous wave (MFCW) radar for micro-Doppler research and detection and classification algorithm design. First, sensor hardware is developed and tested. Various design tradeoffs are considered, with the application of micro-Doppler based detection and classification in …
-
Performance analysis of an adaptive target detector
Not available
-
Analog to digital converter for UWB short range indoor radar system
… is designed for an ultra-wideband short-range radar (UWBSRR) health-event monitoring system. The input signal frequency range for the ADC is 3.2GHz to 4.7GHz. To meet the accuracy and detection requirements of the system, it was derived that a resolution of 4-bits and a sampling speed of 10GHz …
-
Signals in nonlinear bandpass systems / Ian W. Dall
Bibliography: leaves 222-230
-
Introduction of low noise amplifier for ultra-wideband radar receiver
… monitoring system for healthcare monitoring. Radar is a different direction than present research going on at the University of Missouri in that present research uses cameras, sound and movement sensors to monitor subjects. In this thesis, I did work on the receiver part of this UWB system. In …