Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 127 for “"Radiation detector"”.

  1. CdTe/CdZnTe pixellated radiation detector

    … focused on the study of CdTe/CdZnTe pixellated detectors. During this research, three main aspects have been covered in the development and application of these detectors. These broadly describe the fabrication process, characterisation of energy spectrum and imaging performance, and application …

    glasgow Download PDF for CdTe/CdZnTe pixellated radiation detector (opens in a new tab)

  2. MEMS-BASED CAPACITIVE GAMMA RADIATION DETECTOR

    Personal radiation detectors can be used to detect radioactive sources, measure the dose of radiation exposure, or alert those exposed to radiation energy. Applications vary from law enforcement to medical, scientific, power generation and hazardous material (HAZMAT) detection. Most of the …

    nps Repository record for MEMS-BASED CAPACITIVE GAMMA RADIATION DETECTOR (opens in a new tab)

  3. Build and test of a gamma radiation detector

    Gamma radiation detection has been part of research for a long period of time. Being able to detect gamma radiation when being exposed to radiation is a must. The gamma detector I have built will demonstrate that it is capable of detecting gamma radiation with a low budget. We were able to build …

    ttu Repository record for Build and test of a gamma radiation detector (opens in a new tab)

  4. Characterization and evaluation of the microcantilever radiation detector

    … this study, a microcantilever charged-particle detector was characterized and evaluated. The method employed involved sensing an electric field emanating from a small collector plate on which charge built up to charged-particle flux.Sensitivity to alpha particles was determined using frequency …

    ut-knoxville Repository record for Characterization and evaluation of the microcantilever radiation detector (opens in a new tab)

  5. Chalcogenide Semiconductor Single Crystal Growth for Radiation Detector Applications

    Room-temperature radiation detectors are essential for medical imaging, nuclear safety, security, and defense. Suitable detector materials require high density/effective atomic number, an optimal band gap, high resistivity to suppress leakage current, and mechanical robustness for device …

    queens Repository record for Chalcogenide Semiconductor Single Crystal Growth for Radiation Detector Applications (opens in a new tab)

  6. EXPLORATION OF A CARBON NANOTUBE ANODE GAS-FILLED RADIATION DETECTOR

    … model the electrostatic field in a gas-filled radiation detector constructed with either a carbon nanotube (CNT) or a CNT array as the anode. Tungsten anodes of 500 to 4μm diameters were used to observe the gradual decrease in operating voltage with a decreasing anode diameter and estimate …

    clemson Repository record for EXPLORATION OF A CARBON NANOTUBE ANODE GAS-FILLED RADIATION DETECTOR (opens in a new tab)

  7. A Process for ADM-300 Radiation Detector Modernization for Military Applications

    … 1992. The capabilities and features of various detectors are analyzed and compared to the ADM-300. Response curves are generated using Monte Carlo simulations. The detectors are prioritized based on their performance to create metrics. A metanalysis of the metrics is conducted to limit bias …

    unlv Repository record for A Process for ADM-300 Radiation Detector Modernization for Military Applications (opens in a new tab) Download PDF for A Process for ADM-300 Radiation Detector Modernization for Military Applications (opens in a new tab)

  8. Experimental developments towards a long-baseline laser interferometric gravitational radiation detector

    Gravitational radiation (a wave-like disturbance in space-time, propagating with the speed of light) is predicted as a consequence of Einstein's General theory of Relativity. Indirectly verified by observations of the binary pulsar PSR1913+16, gravitational waves have still to be observed directly. …

    glasgow Download PDF for Experimental developments towards a long-baseline laser interferometric gravitational radiation detector (opens in a new tab)

  9. Silicon diodes fabricated on defect-engeneered material for use as radiation detector

    … to incident photons are more pronounced at low radiation fluence but they become negligible as the fluence increases. These results show that silicon gets quickly damaged by radiation in the initial stages of the irradiation process but as the fluence increases the material becomes resistant to …

    nwu-za Repository record for Silicon diodes fabricated on defect-engeneered material for use as radiation detector (opens in a new tab)

  10. MINIATURIZED NEUTRON RADIATION DETECTOR USING BORON-NITRIDE AND MULTI-WALLED CARBON NANOTUBES

    … been previously shown to be a viable option for radiation sensors requiring small, low-cost, and low-power designs. A resistive sensor combining boron-nitride nanotubes and multi-walled carbon nanotubes with an interdigitated electrode design printed with conducting ink can be used to detect …

    nps Repository record for MINIATURIZED NEUTRON RADIATION DETECTOR USING BORON-NITRIDE AND MULTI-WALLED CARBON NANOTUBES (opens in a new tab)

  11. BORON-NITRIDE NANOTUBES AND VERSATILE DIELECTRICS FOR MEMS ELECTRONIC NOSE RADIATION DETECTOR

    As society's use of radiation-producing technologies increases, so does the need to create more effective and versatile radiation detectors. Low-cost, low-power, compact radiation detectors are applicable across an ever-growing range of fields and industries. Micro-electro-mechanical systems (MEMS) …

    nps Repository record for BORON-NITRIDE NANOTUBES AND VERSATILE DIELECTRICS FOR MEMS ELECTRONIC NOSE RADIATION DETECTOR (opens in a new tab)

  12. Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy

    The Timepix detector developed by CERN is a novel and sophisticated particle detector. It consists of a semiconductor layer divided into an array of pixels. This array of pixels is bumpbonded to an electronics integrated layer (i.e. the readout chip). Timepix can be used for a wide range of …

    adelaide Repository record for Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy (opens in a new tab)

  13. Experimental Design for Estimating Electro-Thermophysical Properties of a Thermopile Thermal Radiation Detector

    … turn, rely on accurate measurements of the Earth Radiation Budget (ERB) in order to quantify changes in the atmosphere. The Thermal Radiation Group (TRG), a laboratory in the Department of Mechanical Engineering at Virginia Polytechnic Institute and State University, has been at the edge of …

    vt Repository record for Experimental Design for Estimating Electro-Thermophysical Properties of a Thermopile Thermal Radiation Detector (opens in a new tab)

  14. Characterization of neutron irradiated accident tolerant nuclear fuel cladding silicon carbide & radiation detector deadtime

    … generated by a Geiger Muller (GM) detector and recorded by an oscilloscope manually, were investigated. The objective of part I was (1) to find a correlation between pulse shape and the operating voltage; and (2) to assess if pulse shape properties followed distinct patterns …

    must-thes Repository record for Characterization of neutron irradiated accident tolerant nuclear fuel cladding silicon carbide & radiation detector deadtime (opens in a new tab)

  15. Design and Simulation of a New Generation Radiation Detector for Oil and Gas Exploration

    Radiation detection is extensively used in borehole logging — a technique widely employed in oil and gas, and mineral exploration. The workhorse of this detection application for many years has been traditional 3He tubes in neutron porosity tool and NaI:Tl scintillators coupled with photomultiplier …

    whiterose Download PDF for Design and Simulation of a New Generation Radiation Detector for Oil and Gas Exploration (opens in a new tab)

  16. Dynamic Electrothermal Model of a Sputtered Thermopile Thermal Radiation Detector for Earth Radiation Budget Applications

    … through a Cassegrain telescope. The Thermal Radiation Group, a laboratory in the Department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently studying a new sensor concept to replace the current bolometer: a thermopile thermal radiation detector. …

    vt Repository record for Dynamic Electrothermal Model of a Sputtered Thermopile Thermal Radiation Detector for Earth Radiation Budget Applications (opens in a new tab)

Page 1 of 7