Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 65 for “"Radiative model"”
-
Time dependent collisional radiative model of an extreme ultraviolet driven plasma
… surface. In a previous Particle In Cell (PIC) model by Van der Velden et al. predictions were made of the plasma parameters. In this research a time-dependent Collisional Radiative Model (CRM) is made based on the corona plasma regime. Using non- Maxwellian electron distribution functions …
-
A radiative model for determining plasma dissociation using vacuum ultraviolet self-absorption spectroscopy
… An integral piece of this technique is a radiative transfer simulation for calculating the radiation trapping physics inside the plasma channel volume, executed in the MATLAB® environment and accelerated via GPU resources using the NVIDIA® CUDA architecture. The combination of experimental …
-
Plasma Spectroscopy of Highly Charged Ions by the Method of Collisional-Radiative Model
本文データは平成22年度国立国会図書館の学位論文(博士)のデジタル化実施により作成された画像ファイルを基にpdf変換したものである
-
Rebuilding Optical Emission Spectroscopy Measurements in a Low Density Plasma Facility using a Collisional-Radiative Model
… (OES), complemented with a Collisional-Radiative (CR) model for the prediction of emission line intensities in chemical non-equilibrium conditions, based on a set of plasma parameters. The main objectives are to assess the degree of non-equilibrium of the plasma in DRAG-ON, and to …
-
A Radiative Model for the Study of the Feedback Mechanism between Photolytic Aerosols and Solar Radiation
Since the early 70's chemistry and transport models (ChTMs) have been proposed and improved. Tropospheric ChTMs for trace species are detailed numerical formulations intended to represent the atmospheric system as a whole, accounting for all the individual processes and phenomena that influence …
-
Development of 0 – D argon collisional radiative model conjoined with optical emission spectroscopy for radio frequency plasma
… plasma diagnostic technique, collisional radiative model (CRM), has been gaining attention because it is a non-intrusive diagnostic technique that can compute electron properties by simulating the chemical network within a plasma system, unlike conventional OES while providing elemental …
-
Prediction of air nonequilibrium radiation with a collisional-radiative model : Application to shock-tube conditions relevant to Earth reentry
… de particules lourdes, ainsi que les transitions radiatives. Une revue exhaustive des diverses données expérimentales et théoriques nous a conduit à sélectionner les formulations les plus appropriées. Les transitions radiatives on été traitées via le concept de facteur d’échappement, égal à 0 pour …
-
Investigation of the Optical Emission of Hall Effect Thrusters using a Collisional Radiative Model, Particle-In-Cell Simulations, and Machine Learning
Ce travail propose une analyse de l'émission optique des propulseurs à effet Hall qui repose sur les simulations, la spectroscopie et les réseaux de neurones. L'étude s’ancre dans le contexte dynamique du New Space et des lanceurs réutilisables qui ont amené une réduction considérable des coûts des …
-
Fundamental atomic data and prototype techniques for a generalised collisional-radiative model of medium-weight elements in fusion and astrophysical plasma
… spectroscopy, requires generalised collisional-radiative (GCR) population modelling to produce high-quality ionisation balances and cooling curves. ADAS provides a well-established framework of codes and data for the GCR modelling of light species and has been applied extensively to these …
-
Radiative heat transfer in gallium arsenide lec crystal pullers
A numerical analysis of radiative heat transfer in a liquid encapsulant Czochralski gallium arsenide crystal puller is developed. The heat transfer and equivilent ambient temperature of each surface element are calculated using the Gebhart radiative model. The effective ambient temperature, to …
-
Plasma spectroscopic diagnostic tool using collisional-radiative models and its application to different plasma discharges for electron temperature and neutral density determination
… For each gas, a method of analysis which uses models specific to each species present in the plasma (neutral atom or singly ionized atom) has been defined. The experimental electron density is used as an input parameter to the models, and the absolutely calibrated spectroscopic data are …
-
Characterization of an Inductively Coupled Plasma Preionization Device Using Optical Emission Spectroscopy
… optical emission spectroscopy and a collisional radiative model. The initial experiments and characterization of plasma were done using argon. It was found that two discharges were produced simultaneously within the system, the primary one of inductive nature and the secondary hypothesized to be …
-
Analysis of a Water Vapor Helicon Thruster Using Emission Spectroscopy
… for any propellant. A helium collisional radiative model was developed to estimate electron temperature and density from helium emission line ratios measured experimentally. Thruster tests conducted with pure helium were used to compare the collisional radiative model to existing models. …
-
Pulsed inductive plasma studies by spectroscopy and internal probe methods
… those of steady-state corona and collisional-radiative model assumptions. Electron temperature estimates were highly model dependent with the steady-state corona model yielding temperatures of around 10 eV or less and the collisional-radiative model yielding up to 100 eV. Triple probe …
-
Collisional-radiative modeling and ultrafast laser-induced fluorescence in a helicon plasma device
… studies through the development of a Collisional-Radiative Model for He plasmas. The experiments will be carried out on the Resonant Antenna Ion Device (RAID), a helicon plasma source located at the Swiss Plasma Center. The plasma conditions produced in RAID are similar to those expected in …
-
Dirac R-matrix scattering calculations in support of plasma diagnostics
… data, are incorporated into collisional-radiative model programs. These collisional-radiative models provide great insight for plasma diagnostics and spectral line identification.<br/><br/><br/>
-
Modeling of no radiative emission in non-equilibrium hypersonic flow
… in hypersonic shocks can be measured both by radiative emission and absorption measurements. NO is an ideal optical diagnostic tool because it has a significant absorption cross section, and is a strong emitter in the IR and the UV. The ability to model radiative emission from NO is therefore …
-
In comparing radiative transfer and chemical transport models on OMI NO2 retrievals
… For this study, only the difference between the radiative models and the a priori NO2 chemical transport models were considered relevant. All other parameters, such as cloud properties, slant columns, stratospheric serration and their assumptions, were held constant. Here, the models are referred …
-
A High-Order Transport Scheme for Collisional-Radiative and Nonequilibrium Plasma
… zone, and electron avalanche. Theoretical models were first developed in order to reproduce the length and time scales of the observed quasi-equilibrium state, and later extended to include unsteady plasmadynamic simulations that verified the influence of pressure oscillations in one …
Page 1 of 4