Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"Radio Frequency coil"”

  1. Transdermal Radio Frequency Coil Analysis Using Network Analyzer Measurements for An Artificial Heart Powering System

    … the design and characterization of transdermal coil sets used for artificial heart powering systems. Network analyzer measurements and theory are utilized to develop expressions for coil set modeling and the most efficient two-port network load. Practical aspects involving the use of a network …

    marquette Repository record for Transdermal Radio Frequency Coil Analysis Using Network Analyzer Measurements for An Artificial Heart Powering System (opens in a new tab)

  2. Engineering Parallel Transmit/Receive Radio-Frequency Coil Arrays for Human Brain MRI at 7 Tesla

    … B0. The wavelength associated with the radio-frequency field B1+ has smaller dimensions - approx. 12 cm for human brain tissues - than the human brain itself (20 cm in length), the organ of interest in this thesis. The main consequence is that the transmit field distribution pattern …

    epfl Repository record for Engineering Parallel Transmit/Receive Radio-Frequency Coil Arrays for Human Brain MRI at 7 Tesla (opens in a new tab)

  3. Radio Frequency Coil and Pulse Sequence Design for Hyperpolarised Noble Gas MRI of the Human Lungs and Brain

    … analytical method to design a 1H receiver coil array that functions nested inside a 3He or 129Xe transmit-receive coil. (b) Demonstrate triple-nuclear (129Xe-3He-1H) same-breath lung imaging (structure-ventilation) and dual-nuclear (129Xe-3He) same-breath apparent diffusion coefficient …

    whiterose Repository record for Radio Frequency Coil and Pulse Sequence Design for Hyperpolarised Noble Gas MRI of the Human Lungs and Brain (opens in a new tab)

  4. Radio-frequency coil optimization for MRI of tissues with ultra-short T2*: application in ancient remains and dental tissue

    Die Magnetresonanztomographie (MRT) ist ein vielseitiges, nicht invasives Bildgebungsverfahren, das einen ausgezeichneten Weichteilkontrast für die klinische Diagnostik liefert. Sie erfasst das Kernresonanzsignal von Wasserstoff, meist von Gewebewasser im untersuchten Körperteil. Die MRT ist auch …

    freiburg-diss Repository record for Radio-frequency coil optimization for MRI of tissues with ultra-short T2*: application in ancient remains and dental tissue (opens in a new tab)

  5. Strategies for Maximizing Signal to Noise in Decoupled Receive Coil Arrays for Magnetic Resonance Imaging

    Designing radio frequency coil arrays for optimal Magnetic Resonance Imaging (MRI) has been a wide area of interest for many years. The optimum coil type for high density arrays and the mitigation of coupling between elements in arrays are significant problems addressed in this thesis. Coupling …

    alberta Repository record for Strategies for Maximizing Signal to Noise in Decoupled Receive Coil Arrays for Magnetic Resonance Imaging (opens in a new tab)

  6. Probing the microscopic environment of physiological sodium ions through observation of the T2* relaxation

    … of the temporal sampling and a novel radio frequency coil leading to an increase in signal-to-noise ratio of up to 145 %. With the optimized pattern relaxation times were determined in healthy human white matter to be T2,s*,T2,l* = 4.2 ± 0.4 ms / 34.4 ± 1.5 ms. Compared to linear …

    heid-diss Repository record for Probing the microscopic environment of physiological sodium ions through observation of the T2* relaxation (opens in a new tab)

  7. Numerical and Experimental Study of Pacemaker Safety under MRI

    … issue of pacemaker/defibrillator with MRI RF (radio frequency) coil and human body model, novel techniques for the evaluation of MRI-induced heating or induced voltage in the vicinity of implanted metallic lead have been developed based on the reciprocity theorem. The measurement configurations …

    houston Repository record for Numerical and Experimental Study of Pacemaker Safety under MRI (opens in a new tab)

  8. Nuclear spin dynamics in a microfluidic chip

    … cells and a spatially localised stripline radio-frequency coil. In addition, the feasibility of optimal control techniques, namely Gradient Ascent Pulse Engineering (GRAPE), is tested in isolation to realise the polarisation-transfer step of a para-hydrogen-induced polarisation …

    soton Repository record for Nuclear spin dynamics in a microfluidic chip (opens in a new tab)

  9. DESIGN OF A CONTINUOUS FLOW MAGNETIC RESONANCE SYSTEM FOR RHEOLOGICAL CHARACTERIZATION

    … Magnetic Resonance Imaging system operating at a frequency of 24.15 MHz (~0.50 T), equipped with a radio frequency coil of 10mm was converted to a flow-MR system or the so-called MR-Viscometer to measure the rheological constants of different Newtonian and Non-Newtonian fluids. At the first step, …

    metu Repository record for DESIGN OF A CONTINUOUS FLOW MAGNETIC RESONANCE SYSTEM FOR RHEOLOGICAL CHARACTERIZATION (opens in a new tab)

  10. Human cardiac magnetic resonance spectroscopy

    … 7 tesla scanners over lower field strengths. The radio frequency coil hardware is characterised experimentally. The multivoxel spectroscopy methods used throughout the thesis are described.</li> <li>Chapter 3 details the implementation of an open source spectroscopy fitting program. It is …

    oxford Repository record for Human cardiac magnetic resonance spectroscopy (opens in a new tab)

  11. Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans

    … magnetic resonance devices employ phased array coils made of low impedance resonant loops. Electrodynamic interactions between elements in such arrays must be carefully balanced. To mitigate inductive coupling, neighboring coil components are strategically overlapped, and preamplifier interfaces …

    buffalo Repository record for Design and Numerical Investigation of RF Transceiver Arrays for 7T MR Imaging in Humans (opens in a new tab)

  12. Feasibility of body electrical loss analysis in detection of abdominal visceral fat

    … the subject's abdomen is covered with a radio frequency coil comprising a tunable high-Q LC resonator. No contact electrodes are attached to the subject standing within the coil. The time-varying magnetic field produced by the coil induces so-called eddy currents in the abdomen. The …

    aalto Repository record for Feasibility of body electrical loss analysis in detection of abdominal visceral fat (opens in a new tab)

  13. Entwicklung der Multi-Kanal-Hochfrequenz Technologie für Natrium und Kalium Magnet-Resonanz-Tomographie bei 7.0 Tesla

    … 39K is 0.05% the one of proton (1H). Therefore, radio frequency (RF) coils, which are used to capture these signals, should be optimized for a given anatomical structure in order to improve the SNR. The goal of this work is to develop two separate RF coils which would enable high-resolution in …

    fu-berlin Repository record for Entwicklung der Multi-Kanal-Hochfrequenz Technologie für Natrium und Kalium Magnet-Resonanz-Tomographie bei 7.0 Tesla (opens in a new tab)

  14. The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging

    … this dissertation, a novel RF coil design, termed the wireless integrated parallel reception, excitation, and shimming (iPRES-W) coil design, is further developed to remove some of these wired connections by offering a compact and easy-to-integrate MR-compatible wireless data …

    duke Repository record for The iPRES-W Coil: Advancements in Wireless Technology for Magnetic Resonance Imaging (opens in a new tab)

  15. Modeling and design of resonators for electron paramagnetic resonance imaging and ultra high field magnetic resonance imaging

    The purpose of this work was to use computer-aided design methods to analyze resonant cavities for electron paramagnetic resonance (EPR) and magnetic resonance (MR) imaging. As a result of this analysis, a new design and modifications to existing ones were proposed. The behavior of a L-band …

    ohiolink Repository record for Modeling and design of resonators for electron paramagnetic resonance imaging and ultra high field magnetic resonance imaging (opens in a new tab)

  16. Energy-efficient and miniaturized radio frequency systems for biomedical implants

    … the neural implants: On the one hand, decreased coil diameter and increased operational distances lead to a decrease in power transfer efficiency, which is strongly required to extend operating times with limited energy storages and to reduce heating and electromagnetic emission on the tissue. On …

    freiburg-diss Repository record for Energy-efficient and miniaturized radio frequency systems for biomedical implants (opens in a new tab)

  17. Découplage de détecteurs radiofréquences supraconducteurs à très haute sensibilité pour la micro-imagerie par résonance magnétique

    … jusqu'à présent peu explorées dans le régime radiofréquence (RF). Ceci, dans l'objectif de contrôler la commutation d'antennes supraconductrices ultrasensibles dédiées à l'Imagerie par Résonance Magnétique (IRM), de l'état supraconducteur à un état dissipatif. L'implémentation des antennes …

    star-france Repository record for Découplage de détecteurs radiofréquences supraconducteurs à très haute sensibilité pour la micro-imagerie par résonance magnétique (opens in a new tab)