Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 87 for “"Radiochromic"”.

  1. Implementation of an in vivo radiochromic film QA procedure

    … vivo dosimetry quality assurance procedure using radiochromic film. This research proved that radiochromic in vivo dosimetry is a viable method of detecting spatial patient specific errors in radiotherapy; however, the process is time consuming and not sensitive enough for dosimetric errors …

    missouri Repository record for Implementation of an in vivo radiochromic film QA procedure (opens in a new tab)

  2. THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER

    This research aims to develop a tissue-mimicking material and produce a 3D gelatin that has density of approximately a human lung, which is in the ranges of (0.25 – 0.35) g/cm3. Tissue equivalent models are important in order to study the radiation dose planned for patients. To achieve the desired …

    mcmaster Repository record for THE DEVELOPMENT OF A LOW DENSITY RADIOCHROMIC GEL DOSIMETER (opens in a new tab)

  3. Development of a Novel Readout System for Radiochromic Film Dosimetry

    … precisely delivered to a patient is critical. Radiochromic film dosimetry has been adopted in the clinic as a convenient option for QA because it provides verification in a two dimensional plane, is essentially energy independent, is near tissue equivalent, and has high spatial resolution. …

    queens Repository record for Development of a Novel Readout System for Radiochromic Film Dosimetry (opens in a new tab)

  4. DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER

    … of this research is to fabricate a transparent radiochromic gel dosimeter that may be used as quality assurance tool. Also, the fabricated gel must be analyzed using a simple optical read-out technique.</p> <p>Gel dosimeters are gels that undergo some chemical changes upon irradiation as a …

    mcmaster Repository record for DEVELOPMENT OF A TRANSPARENT AND DEFORMABLE TWO DIMENSIONAL RADIOCHROMIC GEL DOSIMETER (opens in a new tab)

  5. Beta and electron dose imaging using a microspectrophotometer system and radiochromic film

    … using a microspectrophotometer system and radiochromic film, has been investigated. The investigation entailed the commissioning of the microspectrophotometer and the development of a newly proposed method in film calibration. It was tested successfully by comparing the measured dose, …

    mcmaster Repository record for Beta and electron dose imaging using a microspectrophotometer system and radiochromic film (opens in a new tab)

  6. Exploring spatial heterogeneity of radiation dose deposition with radiochromic film and Raman spectroscopy

    This thesis considers dosimetric analysis of EBT-3 films using Raman spectroscopy, aiming to use spectral data to investigate spatial heterogeneity associated with radiation exposure at about the cellular-level of granularity. Herein, we identify two principal peaks serving as indicators of dose …

    ubc Repository record for Exploring spatial heterogeneity of radiation dose deposition with radiochromic film and Raman spectroscopy (opens in a new tab) Download PDF for Exploring spatial heterogeneity of radiation dose deposition with radiochromic film and Raman spectroscopy (opens in a new tab)

  7. Role of water in radiochromic LiPCDA monomer crystal packing and radiotherapy dose response

    Radiochromic films comprised of lithium-10,12-pentacosa diynoate (LiPCDA) crystals, a form of diacetylene, have been developed for in vivo real-time dosimetry. The polymerization of LiPCDA results in a change in optical density that is related to the absorbed dose. The dose response of diacetylene …

    york Repository record for Role of water in radiochromic LiPCDA monomer crystal packing and radiotherapy dose response (opens in a new tab)

  8. Point-based Ionizing Radiation Dosimetry Using Radiochromic Materials and a Fibreoptic Readout System

    … quality assurance and innovation. Two radiochromic materials from GafChromic MD-55 and EBT films have been investigated for applicability in real-time in vivo dosimetry of ionizing radiation. Both films were able to produce a real-time measurement of optical density from a small volume, …

    toronto-retro Repository record for Point-based Ionizing Radiation Dosimetry Using Radiochromic Materials and a Fibreoptic Readout System (opens in a new tab)

  9. Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields

    … indirectly ionizing radiation dosimetry by using radiochromic film (RCF) for a high-resolution, accurate dosimetry system. Using RCF will extend the current field of radiation dosimetry to spatially quantitative 2D and three-dimensional (3D) measurements. </p> <p>This work was generalized into two …

    duke Repository record for Development of Radiochromic Film for Spatially Quantitative Dosimetric Analysis of Indirect Ionizing Radiation Fields (opens in a new tab)

  10. The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods

    … thesis was to fabricate a transparent cryogel radiochromic dosimeter with poly(vinyl alcohol) (PVA) as the gelling agent. A transparent dosimeter may be analyzed using an optical read out technique, which is desirable. PVA cryogels can be made transparent by adding dimethyl sulfoxide (DMSO). …

    mcmaster Repository record for The Development of a Transparent Poly(vinyl alcohol) Radiochromic Cryogel Dosimeter and Optical Detection Methods (opens in a new tab)

  11. Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout

    … and complete dosimeters for brachytherapy. Radiochromic gel dosimeters with optical computed tomography (CT) readout would provide such a dosimeter, but the insertion of brachytherapy catheters into the gel cause streak artifacts in the reconstructed dose distributions, ruining the …

    queens Repository record for Application and Development of Algebraic Reconstruction Algorithms for High Dose Rate Brachytherapy Gel Dosimetry with Optical Computed Tomography Readout (opens in a new tab)

  12. Modelling Low Dose Radiation Deposition using Wavelet-Based Texture Analysis

    … energy deposition and response in irradiated radiochromic film. A challenge to analyzing radiochromic film at this resolution is the heterogeneities present in the films, which impact the film’s reaction to radiation and disrupt the spatial distribution of the radiation deposition. Wavelet …

    carleton Repository record for Modelling Low Dose Radiation Deposition using Wavelet-Based Texture Analysis (opens in a new tab)

  13. VHEE dosimetry in a FLASH: ultrahigh dose rate dosimetry and real-time beam monitoring for very high energy electron FLASH radiotherapy

    … methods for VHEE UHDR beams.</p> <p>A radiochromic film dosimetry protocol was developed for VHEE FLASH experiments at the CLEAR Facility to ensure accurate dose measurements. Various Gaussian beam size determination methods were compared. Charge measurements using an integrated current …

    oxford Repository record for VHEE dosimetry in a FLASH: ultrahigh dose rate dosimetry and real-time beam monitoring for very high energy electron FLASH radiotherapy (opens in a new tab)

  14. Volumetric, Magnetic Resonance-Visible, and Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy

    … investigated existing and novel formulations of radiochromic gel dosimeters. After the optimal radiochromic gel formulation was identified, it was characterized for dose linearity, radiological properties, reproducibility, time stability, energy dependence, reusability, dose rate dependence, …

    uthsc Repository record for Volumetric, Magnetic Resonance-Visible, and Radiation-Sensitive Detectors For Magnetic Resonance Image-Guided Radiation Therapy (opens in a new tab)

  15. Development and Implementation of A Homogeneous and A Heterogeneous Anthropomorphic End to End Quality Assurance Audit System Phantom For Magnetic Resonance Guided Radiotherapy Modalities Ranging From 0.35 T to 1.50 T

    … materials were selected for the MRgRT phantoms, radiochromic film and double-loaded TLDs were then characterized in a 1.5T and a 0.35T MR environment. Reproducibility measurements on double-loaded TLDs were performed by using an acrylic block and irradiating it in 0T/1.5T and 0T/0.35T …

    uthsc Repository record for Development and Implementation of A Homogeneous and A Heterogeneous Anthropomorphic End to End Quality Assurance Audit System Phantom For Magnetic Resonance Guided Radiotherapy Modalities Ranging From 0.35 T to 1.50 T (opens in a new tab)

Page 1 of 5