Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 16 of 16 for “"Radiofrequency coil"”

  1. Triple-Tuned Radiofrequency Coil Designs for Magnetic Resonance Imaging and Spectroscopy

    … many design considerations of multi-nuclear RF coil designs, which are necessary to support biomarker development for Duchenne muscular dystrophy (DMD). This work specifically details the design, construction, and characterization of several triple-tuned coil designs. First, a triple-tuned …

    tamu Repository record for Triple-Tuned Radiofrequency Coil Designs for Magnetic Resonance Imaging and Spectroscopy (opens in a new tab)

  2. Strategies for Artifact Correction and Motion Monitoring in MRI Through Innovations in Radiofrequency Coil Design

    … using innovations in radio-frequency (RF) coil design to address the problems that arise when these assumptions are broken. </p><p>Typically, B_0 inhomogeneities are caused by susceptibility differences at air/tissue interfaces and result in image artifacts such as geometric distortions and …

    duke Repository record for Strategies for Artifact Correction and Motion Monitoring in MRI Through Innovations in Radiofrequency Coil Design (opens in a new tab)

  3. Radiofrequency Coil Design for Magnetic Resonance Imaging and Spectroscopy of the Human Breast and Models of Duchenne Muscular Dystrophy

    … benefits of high field MRI and the use of array coils have enabled studies such as dynamic contrast enhanced MRI (DCEMRI) and diffusion weighted imaging (DWI) with high spatial and/or temporal resolution. These studies provide additional information about morphology and kinetics of breast lesions …

    tamu Repository record for Radiofrequency Coil Design for Magnetic Resonance Imaging and Spectroscopy of the Human Breast and Models of Duchenne Muscular Dystrophy (opens in a new tab)

  4. A size-adaptive radiofrequency coil with integrated NMR field probes for magnetic resonance imaging of the pediatric human brain at 7 T

    … consideration for the design of safe 7 T MRI coils. Because of SAR considerations, there are currently no commercially available 7 T MRI radiofrequency (RF) head coils for imaging pediatric subjects with body weights below 30 kg. Consequently, pediatric neurodevelopmental researchers are …

    mcgill Repository record for A size-adaptive radiofrequency coil with integrated NMR field probes for magnetic resonance imaging of the pediatric human brain at 7 T (opens in a new tab)

  5. Modeling and Simulation of RF Array Systems for Ultra-High Field Magnetic Resonance Imaging

    … contrast resolution than ultra-high field MRI. Radiofrequency coil array systems are widely used in magnetic resonance imaging to gain sensitivity, achieve flexible volume coverage, speed scans with parallel reception, and minimize field nonuniformity with parallel transmission. We developed and …

    buffalo Repository record for Modeling and Simulation of RF Array Systems for Ultra-High Field Magnetic Resonance Imaging (opens in a new tab)

  6. A Longitudinal Study of Tumour Metabolism Using Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopic Imaging in a Preclinical Model of Glioma

    … For first project, a custom-made switch-tunable radiofrequency coil was designed and constructed. This radiofrequency coil facilitated imaging 1H and 13C nuclei without any registration issues producing high signal-to-noise ratio imaging data. In the second project, C6 glioma was implanted into …

    uwo Repository record for A Longitudinal Study of Tumour Metabolism Using Hyperpolarized Carbon-13 Magnetic Resonance Spectroscopic Imaging in a Preclinical Model of Glioma (opens in a new tab)

  7. Approaches Toward Combining Positron Emission Tomography with Magnetic Resonance Imaging

    … were performed to study the impact of radiofrequency coil components on PET image quality and to test the suitability of various MR-compatible materials for a dual-modality animal bed.

    uwo Repository record for Approaches Toward Combining Positron Emission Tomography with Magnetic Resonance Imaging (opens in a new tab)

  8. Quantitative Evaluation of High Impedance Microstrip Array for Ultrahigh Field MR Imaging

    … field nonuniformity with parallel transmission, radiofrequency coil array systems are frequently employed in magnetic resonance imaging. For high-frequency RF coil designs for MR applications, microstrip transmission lines promise great decoupling efficiency, high frequency capability, a better …

    buffalo Repository record for Quantitative Evaluation of High Impedance Microstrip Array for Ultrahigh Field MR Imaging (opens in a new tab)

  9. Magnetic Resonance Systems Development for Point-of-Care MRI Platforms

    … is overcome by designing asymmetric gradient coils which have their imaging region located towards one end of the gradient coil, as opposed to the geometric center, allowing brain imaging. There exists interest in compact configurations which allow imaging further into the cervical spine which …

    uwo Repository record for Magnetic Resonance Systems Development for Point-of-Care MRI Platforms (opens in a new tab)

  10. Hyperpolarized 129Xe Magnetic Resonance Imaging of Radiation-Induced Lung Injury

    … and construction of a Transmit-Only/Receive-Only radiofrequency coil. Another challenge addressed in the thesis was the lack of imaging techniques that provide sufficient spatial and temporal information for gas exchange. Therefore, a novel Hp 129Xe MRI technique was developed based on the …

    uwo Repository record for Hyperpolarized 129Xe Magnetic Resonance Imaging of Radiation-Induced Lung Injury (opens in a new tab)

  11. Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging

    … widespread clinical utilization. In literature, radiofrequency pulse design and multi-acquisition methods with and without parallel transmission systems have been demonstrated for addressing the transmit field inhomogeneity. While substantial improvements have been demonstrated with these …

    utswmed Repository record for Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging (opens in a new tab)

  12. Modelling the short-T2* signal in the liver with ultrashort echo time magnetic resonance imaging (UTE-MRI)

    … were performed on the Prisma for the bandwidth, radiofrequency coil and minimum TE.</p> <p>From the R<sub>2</sub><sup>*</sup> and resonant frequency shift of tendon, an R<sub>2</sub><sup>*</sup> model was developed for describing isotropic collagen and free water in the liver. Other exponential …

    oxford Repository record for Modelling the short-T2* signal in the liver with ultrashort echo time magnetic resonance imaging (UTE-MRI) (opens in a new tab)

  13. Quantitative Evaluation of Microstrip, Dipole and L/C Loop Parallel Transmit (pTx) Arrays for UHF MR Imaging

    … for clinical diagnosis and biomedical research. Radiofrequency coil arrays enhance sensitivity, scan speed, and image consistency across the brain to optimize performance further. Advanced UHF scanners are equipped with 8 or 16 independent parallel transmission (pTx) channels. This allows for …

    buffalo Repository record for Quantitative Evaluation of Microstrip, Dipole and L/C Loop Parallel Transmit (pTx) Arrays for UHF MR Imaging (opens in a new tab)

  14. Diffusion Tensor Imaging at High Magnetic Field

    … be translated to 7 Tesla or 3 Tesla with modern radiofrequency coil arrays.

    alberta Repository record for Diffusion Tensor Imaging at High Magnetic Field (opens in a new tab)

  15. Parallel Radiofrequency Transmission for Safe Magnetic Resonance Imaging of Deep Brain Stimulation Patients at 3 Tesla

    … along the implanted device during resonant radiofrequency (RF) excitation, which can potentially lead to tissue heating and bodily damage. With the technological advancement of ultra-high field (UHF) MRI systems and a growing DBS patient population, DBS MRI safety will become increasingly …

    mcmaster Repository record for Parallel Radiofrequency Transmission for Safe Magnetic Resonance Imaging of Deep Brain Stimulation Patients at 3 Tesla (opens in a new tab)

  16. Metasurface Technology for Ultrahigh Field MRI

    … In addition, traditional quadrature volume coil designs (birdcage, TEM coils), which are common for lower field strengths, become highly sensitive to patient loading at ultrahigh fields. Parallel transmit arrays and B1 shimming are effective at countering the field inhomogeneities, but are …

    alberta Repository record for Metasurface Technology for Ultrahigh Field MRI (opens in a new tab)