Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"Radiostereometric Analysis"”.

  1. Evaluation of model-based RSA for in vivo measurement of polyethylene wear in a total knee replacement

    … in total knee re-placement (TKA). Model-based radiostereometric analysis (MBRSA) is a high accuracy diagnostic tool with the potential to meet this need; however, a number of unknowns must be examined. This research examines optimized patient positioning for MBRSA imaging as well as in vitro …

    manitoba Repository record for Evaluation of model-based RSA for in vivo measurement of polyethylene wear in a total knee replacement (opens in a new tab)

  2. On the fly: Host determinants of RNA virus evolution

    … routine radiographs. Advanced diagnostics using radiostereometric analysis further demonstrated that revision knee implants can remain stable over the long term, regardless of the fixation method used. These findings highlight that innovations in medical devices and diagnostics can improve care, …

    radboud Repository record for On the fly: Host determinants of RNA virus evolution (opens in a new tab) Download PDF for On the fly: Host determinants of RNA virus evolution (opens in a new tab)

  3. Evaluating device-related innovations and advanced diagnostics in knee osteoarthritis: from joint preservation to revision surgery

    … routine radiographs. Advanced diagnostics using radiostereometric analysis further demonstrated that revision knee implants can remain stable over the long term, regardless of the fixation method used. These findings highlight that innovations in medical devices and diagnostics can improve care, …

    radboud Repository record for Evaluating device-related innovations and advanced diagnostics in knee osteoarthritis: from joint preservation to revision surgery (opens in a new tab) Download PDF for Evaluating device-related innovations and advanced diagnostics in knee osteoarthritis: from joint preservation to revision surgery (opens in a new tab)

  4. Using computed tomography imaging to detect early implant migration in total knee replacement

    … can be measured postoperatively using image analysis, and have historically been measured via radiostereometric analysis (RSA) using planar X-ray. Computed tomography (CT)-based RSA (CT-RSA) is the latest technological development for tracking implant migration. CT-RSA is expected to replace …

    manitoba Repository record for Using computed tomography imaging to detect early implant migration in total knee replacement (opens in a new tab)

  5. Quantifying In Vivo Cervical Spine Kinematics: Validation of a Novel Data Collection and Processing Pipeline

    … Accuracy, defined as the error with respect to radiostereometric analysis (RSA) (the “gold standard”), was calculated as 1.39±0.58° in rotational error and 0.97±0.74 mm in translational error. A separate experiment was implemented to validate the RSA. It was determined that RSA techniques …

    calgary Repository record for Quantifying In Vivo Cervical Spine Kinematics: Validation of a Novel Data Collection and Processing Pipeline (opens in a new tab)

  6. Fixation of the cementless oxford unicompartmental knee replacement

    … results of a randomised controlled trial using radiostereometric analysis demonstrated that cementless components are as stable as cemented. Although sufficient in providing component stability, the interference fit could be excessive increasing the risk of fracture. A biomechanical test was …

    oxford Repository record for Fixation of the cementless oxford unicompartmental knee replacement (opens in a new tab)

  7. Movement-Related Pathogenesis of Rotator Cuff Disease in Persons with Shoulder Pain: Effects of Decreased Scapulothoracic Upward Rotation

    … shoulder complex kinematics was validated using radiostereometric analysis in four cadaveric specimens. Shoulder complex kinematics were quantified in 60 participants with and without shoulder pain during scapular plane abduction using the validated protocol. Subject-specific 3D bone models …

    umn Repository record for Movement-Related Pathogenesis of Rotator Cuff Disease in Persons with Shoulder Pain: Effects of Decreased Scapulothoracic Upward Rotation (opens in a new tab)

  8. Developing clinically practical methods for studying mechanical causes of revision in total knee arthroplasty

    … case-control methodology paired with survival analysis techniques could be an efficient study design to measure relationships between surgeon-controlled variables and risk of aseptic revision, requiring as little as 300 revision candidates. Fourth, we propose two techniques, one CT-based and …

    ubc Repository record for Developing clinically practical methods for studying mechanical causes of revision in total knee arthroplasty (opens in a new tab) Download PDF for Developing clinically practical methods for studying mechanical causes of revision in total knee arthroplasty (opens in a new tab)

  9. Fixation of the Oxford unicompartmental knee replacement

    … compared in a randomised controlled study using radiostereometric analysis and fluoroscopic imaging of the interfaces. In the first year the cementless tibial component subsided on average 0.28 mm and had an increased posterior slope of 0.40°, whereas the cemented component only subsided 0.09 mm, …

    oxford Repository record for Fixation of the Oxford unicompartmental knee replacement (opens in a new tab)

  10. The investigation of surrogate markers for post-market surveillance in primary total hip arthroplasty

    … both the femoral and acetabular components was Radiostereometric Analysis. However, this has significant limitations in cost, availability, and the failure to universally predict long-term fixation in all devices. Therefore, alternative surrogate markers that are cost-effective are sought.</p> …

    oxford Repository record for The investigation of surrogate markers for post-market surveillance in primary total hip arthroplasty (opens in a new tab)

  11. Wear of Highly Cross-Linked Polyethylene in Primary Total Hip Replacement

    … The aims of this thesis were to (1) validate radiostereometric analysis (RSA) as the most accurate radiographic method to measure wear of XLPE acetabular components, (2) undertake a scoping review of RSA studies of XLPE wear, and (3) measure bedding-in and wear rate of XLPE using RSA to …

    adelaide Repository record for Wear of Highly Cross-Linked Polyethylene in Primary Total Hip Replacement (opens in a new tab)

  12. To compare radio-stereometric analysis (RSA) and computed tomography (CT) for the assessment of lumbar spinal fusion in a sheep model.

    Study design: A comparison of Radio-Stereometric Analysis (RSA) and Computed Tomography (CT) for the assessment spinal fusion in a large animal model. Introduction and Aims: Anterior Lumbar Interbody Fusion (ALIF) is a surgical procedure that is commonly performed for patients with chronic …

    adelaide Repository record for To compare radio-stereometric analysis (RSA) and computed tomography (CT) for the assessment of lumbar spinal fusion in a sheep model. (opens in a new tab)

  13. Allograft bone in hip revision: the effect of locally applied pharmacological treatment.

    The clinical success of primary hip replacement is paramount but the need for revisions will continue to increase due to the increasing number of operated individuals. In Sweden, the number of hip revisions in 2012 exceeded 2,300. During implant loosening, some of the bone in the femur is lost, …

    lund Repository record for Allograft bone in hip revision: the effect of locally applied pharmacological treatment. (opens in a new tab) Download file for Allograft bone in hip revision: the effect of locally applied pharmacological treatment. (opens in a new tab)

  14. Acetabular Component Migration Following Revision Total Hip Replacement

    … the introduction of new implants and techniques. Radiostereometric Analysis (RSA) and Ein-Bild Roentgen Analyse (EBRA-Cup) are the only validated methods to measure component migration that can predict long-term survivorship of primary THR implants. The advantage of EBRA-Cup is that it can be …

    adelaide Repository record for Acetabular Component Migration Following Revision Total Hip Replacement (opens in a new tab)

  15. Metody 2D-3D registrace modelů pro analýzu konvenčních rentgenových snímků

    Konvenční radiografie hraje klíčovou roli v oblastech dignostiky zlomenin kostí, předoperačního plánování a pooperačního hodnocení ortopedických zákroků. Tato dizertační práce je zaměřena na metody umožňující 3D analýzu konvenčních rentgenových snímků, založené na registraci digitálních modelů. …

    brno-tech Repository record for Metody 2D-3D registrace modelů pro analýzu konvenčních rentgenových snímků (opens in a new tab)

  16. Multi-Axial Motion and Intervertebral Kinematics of the Cervical Spine: Implications for those with Neck Pain

    … lumbar) spine compared to the gold standard of radiostereometric analysis (RSA). 2) Examine head-to-torso and intervertebral kinematics between individuals with chronic neck pain and a healthy cohort. 3) Establish normative global (head-to-torso) kinematics (prediction and confidence intervals) …

    umn Repository record for Multi-Axial Motion and Intervertebral Kinematics of the Cervical Spine: Implications for those with Neck Pain (opens in a new tab)