Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 52 for “"Radiostereometric analysis"”
-
Development and Validation of a Markerless Radiostereometric Analysis (RSA)System
A markerless radiostereometric analysis (RSA) system was developed to measure three- dimensional (3D) skeletal kinematics using biplanar fluoroscopy. A virtual set-up was created, in which the fluoroscope foci and image planes were positioned. Computed tomography (CT) was used to create 3D bone …
-
Shoulder Kinematics and Impingement. Dynamic Radiostereometric analysis of the shoulder
Abstract This study aimed to evaluate the three-dimensional kinematics of the shoulder joint in patients with shoulder impingement and controls with focus on three well known diagnostic tests; painful arc test (active abduction), Neer sign (passive elevation) and Hawkins sign. The shoulder rhythm, …
-
DEVELOPMENT OF ENHANCED CALIBRATION SYSTEM AND MEASUREMENT PROGRAM FOR RADIOSTEREOMETRIC ANALYSIS
Radiostereometric Analysis (RSA) is the gold standard used to evaluate the performance of Total Joint Replacement. However, the assessment of novel surgical procedures is limited by the present accuracy and precision of RSA. At the same time, complications in the measurement of RSA radiographs …
-
Development of a Fluoroscopic Radiostereometric Analysis System With an Application to Glenohumeral Joint Kinematics
… three dimensions, and under dynamic conditions. Radiostereometric analysis (RSA) has the potential to fulfill all of these requirements. The objectives of this thesis were (1) to implement and validate a fluoroscopy-based RSA system, (2) to determine the effect of varying the calibration frame, …
-
Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies
… procedure. Roentgen Stereophotogrammetric Analysis (RSA) is a highly accurate technique that enables three-dimensional measurements of skeletal or implant micromovement with respect to the host bone in vivo. The method has been used in clinical research for the evaluation of penetration of …
-
Assessment of Bone Displacement Under Loading Following Periprosthetic Fracture Repair Using Weight-Bearing CT–Based Radiostereometric Analysis (WBCT-RSA)
… computed tomography with CT- based radiostereometric analysis (WBCT-RSA) as a novel method to assess fracture migration and inducible displacement following surgical fixation of distal femur periprosthetic fractures. Twenty-one participants undergoing revision fracture fixation with …
-
Kinematics and laxity in the knee, before and after Anterior Cruciate Ligament reconstruction. Evaluation using dynamic and static radiostereometric analysis
Introduction: Whether full active and passive extension training, started immediately after an Anterior Cruciate Ligament (ACL) reconstruction, will increase the post-operative A-P laxity of the knee has been the subject of discussion. For many years, many protocols have included full extension …
-
Safety of orthopedic implants: implant migration analysis a must
… (TKAs) and, more broadly, the effect of using Radiostereometric Analysis (RSA) and other markers to detect early loosening. In this thesis, we compared various types of TKAs in different randomized controlled trials. Additionally, we investigated whether the positioning of TKAs relative to the …
-
Radiostereometric and CT-Based Analysis of Implant Stability in Total Hip Arthroplasty
… measuring implant migration remains conventional radiostereometric analysis (RSA); however, the clinical use of RSA is limited due to technical barriers. CT based radiostereometric analysis (CT-RSA), which does not require bone marker beads, offers a clinically applicable alternative. The …
-
In-Vivo Investigation of the Medial Longitudinal Arch of the Foot and Orthotic Interactions using Bi-Planar Fluoroscopy
… bi-planar fluoroscopy was used with markerless radiostereometric analysis (RSA) to measure an angle that defines the MLA with the greatest accuracy to date. MLA angles were significantly smaller (p
-
Validation of the multi-segment foot model with bi-planar fluoroscopy
… This study validated the MSFM against bi-planar radiostereometric analysis (RSA) fluoroscopy. Heel-strike, mid-stance, and toe-off events during the stance phase were compared between motion capture and fluoroscopy. Rise/drop of the medial longitudinal arch showed a significant difference (p < …
-
Evaluation of model-based RSA for in vivo measurement of polyethylene wear in a total knee replacement
… in total knee re-placement (TKA). Model-based radiostereometric analysis (MBRSA) is a high accuracy diagnostic tool with the potential to meet this need; however, a number of unknowns must be examined. This research examines optimized patient positioning for MBRSA imaging as well as in vitro …
-
On the fly: Host determinants of RNA virus evolution
… routine radiographs. Advanced diagnostics using radiostereometric analysis further demonstrated that revision knee implants can remain stable over the long term, regardless of the fixation method used. These findings highlight that innovations in medical devices and diagnostics can improve care, …
-
Assessment of Bone Displacement Under Loading Following Distal Femur Periprosthetic Fracture Repair Using CT-RSA
… thesis examined the effectiveness of CT-based radiostereometric analysis (CT-RSA) for measuring inducible micromotion, movement that occurs from a stimulus, between fracture segments above and below a fracture line, using both conventional and weight-bearing CT. Sixteen participants were …
-
Evaluating device-related innovations and advanced diagnostics in knee osteoarthritis: from joint preservation to revision surgery
… routine radiographs. Advanced diagnostics using radiostereometric analysis further demonstrated that revision knee implants can remain stable over the long term, regardless of the fixation method used. These findings highlight that innovations in medical devices and diagnostics can improve care, …
-
Risk factors for long-term failure of orthopaedic medical devices: taking advantage of RSA as an early detection tool
… to decrease the risk of loosening. Given that radiostereometric analysis (RSA) is a highly accurate method to detect early implant migration which is predictive for late loosening, new implant designs should ideally be tested with RSA before widespread introduction onto the market. In this …
-
Effects of Acetabular Positioning in Total Hip Arthroplasty
… hips with highly crosslinked polyethylene using radiostereometric analysis. Absolute and relative acetabular position was found to be weakly correlated with functional outcomes but the results are not clinically significant. Furthermore, cup position did not correlate with polyethylene wear in …
-
Clinical evidence of novel arthroplasty implants: the essential contribution of implant migration analysis
This thesis investigates how radiostereometric analysis (RSA) can improve patient safety by providing objective evidence on the performance of new arthroplasty implants. RSA measures implant migration, which reflects implant-bone fixation, whereas patient-reported outcome measures (PROMs) assess …
-
Facts and fiction in hip fracture treatment
… and modern implants was studied with the use of radiostereometric analysis (RSA). Chapter 8 presents the results of a retrospective cohort study concerning the pre- and post-operative radiographic fracture characteristics in relation to patient age and the occurrence of reoperation. The surgeons' …
-
Using computed tomography imaging to detect early implant migration in total knee replacement
… can be measured postoperatively using image analysis, and have historically been measured via radiostereometric analysis (RSA) using planar X-ray. Computed tomography (CT)-based RSA (CT-RSA) is the latest technological development for tracking implant migration. CT-RSA is expected to replace …
Page 1 of 3