Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 140 for “"Radiosurgery."”.

  1. Radiosurgery for Malignant Brain Tumors

    Radiosurgery using the Linear Accelerator or the Gamma Knife has proven to be an effective treatment modality for malignant brain tumors. In comparison to other treatments, radiosurgery can be performed on an outpatient basis and is noninvasive (Table 5). Due to the functional properties of …

    vcu Repository record for Radiosurgery for Malignant Brain Tumors (opens in a new tab)

  2. Quantification of Uncertainty in Stereotactic Radiosurgery

    Stereotactic radiosurgery is a highly conformal form of radiation therapy that delivers a high dose of radiation in a single treatment. Since stereotactic radiosurgery is commonly used for brain cancer treatment it is critical that the healthy tissue surrounding the tumor receives as little damage …

    calgary Repository record for Quantification of Uncertainty in Stereotactic Radiosurgery (opens in a new tab)

  3. Stereotactic Radiosurgery Implementation at Utah Valley Hospital

    … Valley Hospital (UVH) implemented a stereotactic radiosurgery (SRS) program as an additional line of service. SRS as defined by the American College of Radiology is radiation therapy delivered via stereotactic guidance with approximately 1 mm targeting accuracy to intracranial targets in 1-5 …

    unlv Repository record for Stereotactic Radiosurgery Implementation at Utah Valley Hospital (opens in a new tab) Download PDF for Stereotactic Radiosurgery Implementation at Utah Valley Hospital (opens in a new tab)

  4. Optimisation Methods for Advanced Gamma Knife Radiosurgery Treatment

    Stereotactic radiosurgery is a high-precision mode of radiotherapy that delivers high dose radiation to brain tumours in one or a few sessions. Recent developments in Gamma Knife radiosurgery machines (Elekta AB, Stockholm, Sweden) have increased treatment precision and functionality, allowing the …

    toronto-retro Repository record for Optimisation Methods for Advanced Gamma Knife Radiosurgery Treatment (opens in a new tab)

  5. Fiducial-free alignment verification techniques for intracranial radiosurgery

    This thesis serves as the basis for a method using image registration to automate patient alignment in an effort to eliminate the dependency on the fiducial markers as well as improve the accuracy efficiency of the alignment process. Proton beams are an external beam modality of radiation therapy …

    csusb Repository record for Fiducial-free alignment verification techniques for intracranial radiosurgery (opens in a new tab)

  6. Fiducial-free alignment verification techniques for intracranial radiosurgery

    This thesis serves as the basis for a method using image registration to automate patient alignment in an effort to eliminate the dependency on the fiducial markers as well as improve the accuracy efficiency of the alignment process. Proton beams are an external beam modality of radiation therapy …

    csusb-retro Repository record for Fiducial-free alignment verification techniques for intracranial radiosurgery (opens in a new tab)

  7. Outcomes after gamma knife radiosurgery for intraventricular meningiomas

    … location. Treatment with stereotactic radiosurgery (SRS) is sparsely reported in the literature. We describe our experience over the last 35 years using Gamma knife radiosurgery (GKRS) for IVMs. Methods We retrospectively reviewed the GKRS database identifying 2501 meningiomas treated …

    rosario Repository record for Outcomes after gamma knife radiosurgery for intraventricular meningiomas (opens in a new tab)

  8. Stereotactic localization and targeting accuracy for experimental proton radiosurgery

    … was to improve an existing experimental proton radiosurgery system at Loma Linda University Medical Center to reach sub-millimeter accuracy before proton radiosurgery with narrow beams can be used in a clinical trial. Protons, different from photons (i.e., x-rays or gamma rays), are charged with …

    csusb Repository record for Stereotactic localization and targeting accuracy for experimental proton radiosurgery (opens in a new tab)

  9. Optimized and integrated alignment system for functional proton radiosurgery

    In this thesis work, a system for proton beam alignment was studied and optimized in many of its functional areas. The resulting system was named Positioning Alignment Control System (PACS). The PACS system is an integrated and efficient system as a result of the work done on it in the course of …

    csusb Repository record for Optimized and integrated alignment system for functional proton radiosurgery (opens in a new tab)

  10. Stereotactic localization and targeting accuracy for experimental proton radiosurgery

    … was to improve an existing experimental proton radiosurgery system at Loma Linda University Medical Center to reach sub-millimeter accuracy before proton radiosurgery with narrow beams can be used in a clinical trial. Protons, different from photons (i.e., x-rays or gamma rays), are charged with …

    csusb-retro Repository record for Stereotactic localization and targeting accuracy for experimental proton radiosurgery (opens in a new tab)

  11. Optimized and integrated alignment system for functional proton radiosurgery

    In this thesis work, a system for proton beam alignment was studied and optimized in many of its functional areas. The resulting system was named Positioning Alignment Control System (PACS). The PACS system is an integrated and efficient system as a result of the work done on it in the course of …

    csusb-retro Repository record for Optimized and integrated alignment system for functional proton radiosurgery (opens in a new tab)

  12. Vascular targeting enhancement of radiosurgery for cerebral arteriovenous malformations

    … (sTF) in an animal model of AVM treated with radiosurgery. Methods: Stereotactic radiosurgery (SRS, 20 animals) or sham radiation (12 animals) was administered to an animal model of AVM in 32 male Sprague-Dawley rats. Twenty- four hours after intervention, animals received an intravenous …

    unsw Repository record for Vascular targeting enhancement of radiosurgery for cerebral arteriovenous malformations (opens in a new tab)

  13. Dose Calculation and Prediction Methods for Gamma Knife Stereotactic Radiosurgery

    Implementation of automation routines leveraging deep learning (DL) methods has been a growing topic of interest. The focus of this work is on the Gamma Knife (GK) workflow, specifically the approximation of dose distributions from GK plan parameters and the prediction of dose distributions using …

    lsu-thes Repository record for Dose Calculation and Prediction Methods for Gamma Knife Stereotactic Radiosurgery (opens in a new tab)

  14. Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery

    … setup error needed to impact stereotactic radiosurgery (SRS) treatments is not well defined. The purpose of this study was to explore potential rotational setup error thresholds for SRS treatments of brain metastases. The groups analyzed in this study consisted of either single isocentric …

    calgary Repository record for Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery (opens in a new tab)

Page 1 of 7