Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 9 of 9 for “"Radiotherapy verification"”
-
A novel deformable phantom for 4D radiotherapy verification /
… of respiratory motion is to use four-dimensional radiotherapy. While analytical models are useful, it is essential that the motion problem in radiotherapy is addressed by both modeling as well as experimentally studies so that different obstacles can be overcome before clinical implementation of a …
-
Automatic image segmentation and correlation in radiotherapy verification
Two active topics in radiation therapy treatment verification, portal image segmentation and correlation, are addressed, and a robust algorithm for automatic segmentation of portal images and portal image registration with respect to a reference image is developed. Morphological techniques have …
-
A large area MAPS-based upstream device for radiotherapy verification
Radiotherapy is a cancer therapy in which ionising radiation is used to target cancerous tissue within the human body. The therapeutic aim is to irradiate cancerous tissue and create DNA strand breaks such that the cancerous tissue is unable to self-repair and subsequently dies. The primary …
-
Real-time, upstream, radiotherapy verification using a CMOS Monolithic Active Pixel Sensor System
… is a need for independent quality assurance in radiotherapy, such as IMRT and VMAT. This thesis presents a real-time upstream intra-fraction verification system using an array of CMOS Monolithic Active Pixel Sensors (MAPS). The system is designed for two key functions: real-time, high-precision …
-
The dual development of an optical tomographic scanner and three dimensional gel dosimeter for complex radiotherapy verification
The state-of-the-art radiotherapy delivery treatments available today require that the intended dose distributions delivered are verified by volumetric gel dosimetry. The development of tissue equivalent gel dosimeters that provide an integrated assessment of the dynamic treatments, are primarily …
-
Image analysis for the assessment of stereotactic radiosurgery
… is described. A technique for the experimental verification of calculated three-dimensional (3D) dose distributions is presented. This computerized approach is based on stereotactic principles and uses a plastic phantom and radiotherapy verification film as the dosimeter. The results indicate …
-
Open source software development for radiochromic film dosimetry analysis
… supporting its continued use in modern radiotherapy verification.
-
in vivo patient dose verification of volumetric modulated arc therapy including stereotactic body radiation treatment applications using portal dose images
… technical innovation. A system of dose delivery verification has the potential to catch treatment errors and therefore improve patient safety. The goal of this thesis was to create a portal image-based in vivo dose reconstruction model for volumetric modulated arc therapy (VMAT) deliveries, …
-
Patient-specific in-vivo QA in MRGRT: 3D EPID dosimetry for the Unity MR-linac
Radiotherapy treatments need adequate quality control (QC) to ensure a correct delivery of the prescribed dose to the target area. One of the most extended safety nets for treatments in conventional radiotherapy machines is in-vivo EPID dosimetry, which uses the dose acquired by an Electronic …