Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"Radon transforms."”
-
Spherical radon transforms and mathematical problems of thermoacoustic tomography
The spherical Radon transform (SRT) integrates a function over the set of all spheres with a given set of centers. Such transforms play an important role in some newly developing types of tomography as well as in several areas of mathematics including approximation theory, integral geometry, …
-
Study of generalized Radon transforms and applications in Compton scattering tomography
… le rayonnement primaire), la transformée de Radon définie sur les lignes droites est apparue comme le modèle naturel. Mais en tomographie Compton, l'information mesurée est liée à l'énergie de diffusion et ainsi à l'angle de diffusion.Ainsi la géométrie circulaire induite par le phénomène de …
-
Hardy Space Theory And Endpoint Estimates For Multi-Parameter Singular Radon Transforms
… studied the L p theories for the singular Radon Trans- forms. Furthermore, B. Street in [68], and Stein and Street in [64–67] extended the theories of the L p boundedness for multi-parameter singular integral operators, such as the Calderón Zygmund operators and singular Radon transforms. …
-
Reconstruction of Radar Images by Using Spherical Mean and Regular Radon Transforms
The goal of this study is the recovery of functions and finite parametric distributions from their spherical means over spheres and designing a general formula or algorithm for the reconstruction of a function f via its spherical mean transform. The theoretical study is and supported with a …
-
Seismic applications of the Radon transform and a new second-order traveltime local transform
Radon transforms play an essential role in seismic data processing. They have been extensively used to separate signals from coherent noise, reconstruct seismic data, and estimate the arrival direction of waves impinging on arrays. This thesis focuses on applying Radon transforms to seismic signal …
-
Applications of microlocal analysis to some hyperbolic inverse problems
… injectivity and stability of some generalized Radon transforms. Each problem is approached using microlocal methods. In the context of thermoacoustic tomography under the damped wave equation, I show uniqueness and stability of the problem with complete data, provide a reconstruction algorithm …
-
Robust Sparse Recovery via Matching Pursuit Algorithms and Applications to Simultaneous-Source Seismic Data Processing
… including the design of high-resolution transforms for coherent noise removal, signal separation, and seismic waveeld reconstruction. Traditional sparse reconstruction algorithms optimally work with noise-free data or data contaminated with random noise of Gaussian distribution. Their …
-
Electro-Optic Range Signatures of Canonical Targets Using Direct Detection LIDAR
… by means of Tomographic Reconstruction using Radon Transforms and by image processing techniques such as Deconvolution.
-
Multiple suppression in the t-x-p domain
… velocity filters for demultiple operations using Radon transforms traditionally face challenges when the water column is shallow. Additionally, the hyperbolic Radon Transform can be computationally expensive. In this thesis, I introduce a novel multiple suppression technique in the t-x-p domain, …
-
Retroreflective shadowgraph of clustered rocket nozzles
… rapidly within the first two nozzle diameters. Radon transforms of the spatially resolved shadowgraphy images are then used to characterize the statistical behavior of the acoustic wavefronts that reside within the hydrodynamic periphery of the nozzle flow during fixed operations of the nozzle …
-
MATHEMATICS OF COMPUTED TOMOGRAPHY (RADON TRANSFORM).
A review of the applications of the Radon transform is presented, with emphasis on emission computed tomography and transmission computed tomography. The theory of the 2D and 3D Radon transforms, and the effects of attenuation for emission computed tomography are presented. The algebraic iterative …
-
Applications of Nonstandard Analysis in Probability and Measure Theory
… some previously known results on Gaussian Radon transforms as limits of spherical integrals. This first area has roots in the kinetic theory of gases, which is also described. In the latter area, we prove a new generalization of de Finetti's theorem for exchangeable random variables, a …
-
GEOPHYSICAL SITE CHARACTERIZATION OF THE MCQUAT LAKE SYNFORM MARY RIVER DISTRICT, BAFFIN ISLAND CANADA
… filters, curvelet SVD filters, FK filtering and Radon transforms to improve first arrival amplitudes and selection. Resulting first arrivals were selected and combined with survey geometry to create tomographic and velocity models using Schlumberger VISTATM Seismic Suite and Optim SEISOPT 2DTM. …
-
Computational Methods for Image Rotation and Computer Aided Tomography Volume I: Theoretical Basi. Volume II: Computer Software
… identify an optimum algorithm for computing the Radon transform - optimum in the sense of minimum CPU time for maximum image fidelity. This transform is the basis for a wide range of applications which are either directly or indirectly associated with Computer Aided Tomography. It has therefore …
-
Seismic-Style Processing of Numerical Em Data
… does not appear to be promising. Linear Radon transforms also detect the reservoir. Standard seismic processing methods are modified to account for the strong frequencydependence of the EM data, in order to focus on the resistivity. Moveout as a function of frequency is replaced by …
-
Iterative reconstruction of three-dimensional magnetic resonance images from boron data
… sampling algorithm is modified such that true Radon projection data is obtained and geometrical symmetries are induced. The image is modeled as a linear combination of Kaiser-Bessel basis functions whose 3D Radon transforms are derived. Iterative 3D reconstruction algorithms have vast memory …
-
TWO-DIMENSIONAL SIGNAL PROCESSING IN RADON SPACE (OPTICAL SIGNAL, IMAGE PROCESSING, FOURIER TRANSFORMS).
… transformation. This approach is based on the Radon transform, which maps a two-dimensional Cartesian representation of a signal into a series of one-dimensional signals by line-integral projection. The mathematical principles of this transformation are well-known as the basis for medical …
-
Implementations and applications of the sparse Radon transform
The Radon transform (RT) has many desirable properties which make it particularly useful for multiple removal and interpolation of seismic reflections. However many practical difficulties arise as a consequence of poor sampling and limited aperture in the offset dimension. Furthermore the ever …
-
THE DISCRETE RADON TRANSFORM WITH APPLICATIONS TO TIME DOMAIN BEAMFORMING
Performing a discrete Radon transform (DRT) with an array of space-time samples results in a function of slowness (inverse velocity) and time intercept. Time domain beamforming and semblance, two commonly used methods of obtaining a slowness-time analysis, give outputs that are composed of discrete …
Page 1 of 2