Charged particle therapy, ion range verification, prompt radiation
Cette thèse porte sur les mesures expérimentales des γ-prompts créés lors de la fragmentation du faisceau d'ions carbone en hadronthérapie. Deux expériences ont été effectuées aux laboratoires GANIL et GSI avec des ions 12C6+ de 95MeV/u et 305MeV/u irradiant une cible d'eau ou de PMMA. Dans les …
-
Secondary prompt gamma-rays to improve proton range verification
… of PG may be used to offer real-time dose verification for proton therapy. In this study PG analysis was performed for MC simulations to evaluate the characteristic measurements and total yield of secondary PG emitted from a target in the 0-8 MeV range from a proton therapy beam over a …
-
Nuclear prompt gamma spectroscopy for range verification in ion-beam therapy
… profile presenting the maximum at the end of range of the primary particles. This feature potentially allows delivering highly conformal radiation therapy, depositing most of the dose in the target volume and sparing the healthy tissue surrounding it. Despite its expanding clinical …
-
Feasibility of On-line Proton Beam Range Verification with Positron Emission Tomography Imaging
… been adopted clinically to verify proton beam range (BR) in proton therapy. Conventional approaches use off-line verification that verifies BR after delivery of full dose of a treatment fraction. This verification can be used to check the accuracy of current therapy retrospectively, but its …
-
A Phantom Study of In-beam PET Imaging for Proton Beam Range Verification
… image-based method to verify the proton beam range for proton therapy by measuring proton-induced positron activity distribution and activity range. This study investigates the feasibility, accuracy and precision of the activity range measurement with a high-performance compact PET prototype …
-
A new prompt gamma spectroscopy-based approach for range verification in proton therapy
… in a localized region close to the end of their range (called the Bragg Peak BP). The combination of the favorable depth-dose profile with advanced delivery techniques translates into a high dose conformality in the tumor, as well as into a superior sparing of normal tissue compared to …
-
A new treatment planning concept accounting for prompt gamma imaging for proton range verification
Protenentherapie zur Behandlung von Tumorerkrankungen ist stark abhängig von der Präzision des Protonenstrahls. Die Reichweite von Protonen unterliegt Unsicherheiten, zum Beispiel verursacht durch die Positionierung des Patienten, durch die semi-empirische Umwandlung von Röntgen-CT-Werten in das …
-
Proton Range Verification for Irradiation of Anthropomorphic Phantoms Implemented in Geant4 Monte Carlo Simulations
… to the presence of a dose peak at the end of the range of the proton beams, denoted Bragg peak, followed by an abrupt fall in dose deposition. This phenomenon allows for targeted irradiation of tumors while minimizing the damage to surrounding healthy tissues. However, morphological changes …
-
Prompt gamma-ray imaging of nanoparticles for in vivo range verification in proton therapy
… to traditional photon radiotherapy. In vivo range verification techniques are required to fully exploit the advantages of proton therapy. In the past few years, the use of nanoparticles as dose enhancers has increased due to their potential amplifying the ra- diation induced damage. This …
-
A Novel Method of Sub-milimeter Range Verification for Hadron Therapy using a Tumour Marker
… a novel technique for in-vivo proton therapy range verification, and share the results of multiple experiments to determine its feasibility. This technique makes use of a hadron tumour marker (HTM), implanted at a short distance from the clinical treatment volume. Signals emitted from the …
-
Nuclear methods for real-time range verification in proton therapy based on prompt gamma-ray imaging
… to photon therapy. Nonetheless, inherent range uncertainties cast doubts on the irradiation of tumours close to organs at risk and lead to the application of conservative safety margins. This constrains significantly the potential benefits of proton over photon therapy and limits its …
-
Toward the Clinical Application of the Prompt Gamma-Ray Timing Method for Range Verification in Proton Therapy
… method offers a relatively simple approach for range verification in proton therapy. Starting from the findings of previous experiments, several steps toward a clinical application of PGT have been performed in this work. First of all, several scintillation materials have been investigated in …
-
On the electromagnetic field of a proton beam as a basis for range verification in particle therapy
… of protons within the patient, known as the range, is however subject to uncertainties, which can lead to significant underdosage in the tumor and excessive dose to critical structures. Inaccuracies can originate from imaging, anatomical changes, patient positioning, just to name a few. Such …
-
Experimental Validation of Filtered Interaction Vertex Imaging for Intra-Fraction Relative Range Verification in Heavy-Ion Therapy
… delivery due to uncertainty surrounding ion beam range in tissue. Relative range verification via filtered interaction vertex imaging could monitor the spacing of each treatment beam endpoint, ensuring full and consistent tumour coverage. To validate this method, twelve \(^{16}O\) beams of …
-
System design and experimental validation of a novel small-animal in-beam PET scanner for hadrontherapy range verification
… a PET-based framework for online proton-beam range verification in small-animal models, with an extension to radioactive ion beams. A novel spherical in-beam PET scanner, composed of 56 pyramidal-stepped DOI-capable LYSO scintillator blocks, was designed and characterized through Monte Carlo …
-
Development of a prompt γ-ray timing system including a proton bunch monitor for range verification in proton therapy
Treatment verification is demanded to mitigate the range uncertainties in proton therapy and, hence, to enhance treatment precision and outcomes. As a non-invasive approach for range verification, the prompt γ-ray timing (PGT) measures the time distribution of the promptly produced γ-rays using …