Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 14 of 14 for “"RayStation"”.

  1. Intensity modulated proton therapy in lung cancer

    … method. [2] To evaluate the accuracy of the Raystation TPS analytical dose calculation (ADC) algorithm against Raystation Monte-Carlo (MC) algorithm. [3] To identify a sub-group of lung clinical cases where the Raystation TPS analytical algorithm may be clinically acceptable. [4] To identify …

    oxford Repository record for Intensity modulated proton therapy in lung cancer (opens in a new tab)

  2. Monte Carlo simulations for brachytherapy

    … prototype in the treatment planning system RayStation®. In addition to constructing the input data, dose distributions for two different treatment plans are scored with egs_brachy in both water and tissue. The same treatment plans are used to compute dose with TG43 and the brachy Monte Carlo …

    chalmers Repository record for Monte Carlo simulations for brachytherapy (opens in a new tab)

  3. Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc

    … regions. Treatment plans are generated using the RayStation (RaySearch) treatment planning system (TPS). MC simulations of dose are performed on voxelized (2.5 mm³) patient CT datasets. Planning-target-volume (PTV) and organs-at-risk (OAR) dose-volume histograms (DVH) are compared to TPS …

    ubc Repository record for Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc (opens in a new tab) Download PDF for Validation of Monte Carlo simulation of 6 MV photon beam delivered by the Vero4DRT linear accelerator using BEAMnrc and DOSXYZnrc (opens in a new tab)

  4. Commissioning And Validation Of Analytical And Monte Carlo Based Dose Calculation Algorithms For Proton Spot Scanning

    … SCCA proton therapy center were commissioned in RayStation treatment planning system. Measurements were performed using variety of detectors such as parallel plate ion chambers, 2D ion chamber arrays, Bragg peaks chamber, 2D high resolution scintillation imager, and radiographic film. The …

    wayne-thes Repository record for Commissioning And Validation Of Analytical And Monte Carlo Based Dose Calculation Algorithms For Proton Spot Scanning (opens in a new tab)

  5. Spatially fractionated proton therapy: A Monte Carlo verification

    … by the Monte Carlo code MCNP and validated by RayStation experimental Gafchromic film EBT3. The results are compared with those of the grid using megavoltage x-rays.

    gatech Repository record for Spatially fractionated proton therapy: A Monte Carlo verification (opens in a new tab)

  6. Deformable Dose Accumulation Evaluation with Spatial Corrective Guidance Using Subregion Analysis

    … framework was implemented as a clinical tool in RayStation and applied to 96 esophageal dose pairs from 65 thoracic re-irradiation patients. Logistic regression with bootstrap resampling tested whether spatial-quality filtering improved esophagitis prediction (17 events, 26%). Maximum subregion …

    jhu Repository record for Deformable Dose Accumulation Evaluation with Spatial Corrective Guidance Using Subregion Analysis (opens in a new tab)

  7. Assessment of Adaptive Radiotherapy Workflows for Head and Neck Cancer

    … EPIs with a Varian linear accelerator and the RayStation treatment planning system, and b) apply the script in a treatment simulation environment to explore the correlation between relative change in EPID measured transit dose and relative change in dose volume histogram (DVH) metrics to target …

    adelaide Repository record for Assessment of Adaptive Radiotherapy Workflows for Head and Neck Cancer (opens in a new tab)

  8. Characterization of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations

    … collimator (MLC) characteristics in Eclipse and RayStation. Finally, previous phantom irradiation cases with concurrent survey results were investigated for relationships between beam modeling parameter choice and phantom performance accuracy. The overwhelming majority of failing (>7% error) and …

    uthsc Repository record for Characterization of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations (opens in a new tab)

  9. Development of Lineal Energy Spectrum-Based Biological Effects Models for Protons

    … incorporated into a treatment planning system, RayStation IonPG-2023B. Having made the rapid calculation of proton lineal energy spectra possible, investigations to establish and determine the optimal mathematical formulation of a mathematical radiobiological model for the prediction of the …

    uthsc Repository record for Development of Lineal Energy Spectrum-Based Biological Effects Models for Protons (opens in a new tab)

  10. IMRT and Rotational IMRT (mARC) Using Flat and Unflat Photon Beams

    … with Step and Shoot (S&S) IMRT by using a RayStation planning system. The mARC plans created by FF and FFF beams were evaluated to know which technique is the best. All the treatment plans were created for simple and complex shaped target volumes. The treatment plans are compared using two …

    qucosa-diss

  11. A comprehensive Monte Carlo model and its experimental validation to characterise and optimise a novel proton preclinical beamline for small animal radiation research

    … des Bestrahlungsplanungssystems (TPS) μ-RayStation (RaySearch Laboratories AB, Stockholm, Schweden) verwendet. Die Phasenraumdaten dienten zudem als Referenz („Ground Truth“) für nachgelagerte Bildgebungs- und Dosimetrie-Arbeitspakete im SIRMIO-Projekt. Beim Vergleich des in …

    lmu-germany Repository record for A comprehensive Monte Carlo model and its experimental validation to characterise and optimise a novel proton preclinical beamline for small animal radiation research (opens in a new tab)

  12. Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt

    … 4DCT-based dose accumulation pipeline in RayStation (RaySearch Laboratories, Stockholm, Sweden). With a sample of 67 IMRT patients, our results showed that the accumulated dose was statistically different than the planned dose across the entire cohort with an average MLD increase of ~1 Gy …

    uthsc Repository record for Improving Dose-Response Correlations For Locally Advanced Nsclc Patients Treated With Imrt Or Pspt (opens in a new tab)

  13. Development and Evaluation of Novel Applications for the Ethos CBCT-Guided Online Adaptive Radiotherapy System

    … of conventional planning/treatment with Raystation/Halcyon is demonstrated with this work and serves as a benchmark comparison for the developed methodology using Ethos. The efficiency gains when utilizing semi-automated planning/online-adaptive treatment with Ethos for immunostimulatory …

    usf Repository record for Development and Evaluation of Novel Applications for the Ethos CBCT-Guided Online Adaptive Radiotherapy System (opens in a new tab)