Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 307 for “"Reaction Monitoring"”.
-
Automation of reaction monitoring
… throughput screening and the recent machine-led reaction discovery, there is increased interest to integrate artificial intelligence and robotics beyond medicinal and synthetic organic chemistry. The addition of automation to mechanistic studies can improve the method in which reactions are …
-
Reaction monitoring using real-time methods
… is a powerful method to monitor organometallic reactions. It is fast at generating spectrum, soft to fragile organometallic compounds and sensitive to intermediates in low concentration. When coupled with the pressurized sample infusion (PSI) that helps to continuously inject reacting solution …
-
Development of mass spectrometry techniques for real-time reaction monitoring
… will serve to assist development of real-time reaction monitoring. To do this, a cationic ionic liquid, butyl methylimidazolium, [BMIM]+, was paired with several counterions and mixed in various solvents. This was analyzed by ESI mass spectrometry to determine the relative response ratio …
-
Reaction monitoring using SABRE-hyperpolarised benchtop (1 T) NMR spectroscopy
This thesis develops novel methods for reaction monitoring using a low field (1 T, 43 MHz) benchtop NMR spectrometer combined with hyperpolarisation using the signal amplification by reversible exchange (SABRE) technique. Industry-friendly benchtop NMR spectrometers suffer from insensitivity, which …
-
Birefringent single-arm fiber optic enthalpimeter for catalytic reaction monitoring
… are almost universally associated with chemical reactions. Thermometry as an analytical tool has been extensively researched and developed. Finding solutions to problems involving thermal isolation, specificity, sensitivity, and cross-sensitivity remain as active areas of interest. Fiberoptic …
-
Analytical techniques for reaction monitoring, mechanistic investigations, and metal complex discovery
… for their ability to provide insights into reaction mechanisms as well as active intermediate speciation. Pressurized Sample Infusion-Mass Spectrometry (PSI-ESI-MS), ion mobility-mass spectrometry (IMS-MS), and Nuclear Magnetic Resonance (NMR) spectroscopy are powerful analytical techniques …
-
Butyl acrylate/vinyl acetate emulsion copolymerization: Reaction monitoring and property evaluation.
… in this thesis. Polymerization process monitoring is a key factor in obtaining high quality products with prespecified properties. Therefore, a considerable part of this work was devoted to the real-time monitoring of BA/VAc emulsion polymerization reactions. An Attenuated Total …
-
Streamlining access to high value molecules through automated synthesis and reaction monitoring
… Automating repetitive, but necessary, reactions enables more time to be focused on new and innovative research. This thesis highlights the use of automation in three case studies to perform these repetitive, but necessary, reactions. The first study details our collaboration with the …
-
Analysis of urinary lipid biomarker candidates from tuberculosis patients by multiple reaction monitoring
… of biomarker candidates, and targeted multiple reaction monitoring (MRM) is the method of choice for subsequent validation of biomarker candidates. A list of candidate urinary biomarkers has previously been generated which can discriminate between latent and active TB infection using MS1 mass …
-
Advancing process analytical technology for solution-phase reaction monitoring through data analysis and automated technologies
… of underlying chemistry, more efficient reaction conditions, and safer manufacturing processes. Recent advances in hardware and automation have allowed PATs to be integrated into increasingly complex chemical systems, while progress in computation and chemometric modelling enables …
-
The control and analysis of one-pot multistep reactions by automation and reaction monitoring technologies
… control, and optimization of chemical reactions largely depend on the apt selection of suitable analytical methodologies. For simpler reactions, characterized by straightforward setups and a limited number of reaction components, success can typically be achieved through the combination …
-
Bayesian Classification of Proteomics Biomarkers from Selected Reaction Monitoring Data Using an ABC-MCMC Approach
Selective reaction monitoring (SRM) has become one of the main methods for low-mass range targeted proteomics by mass spectrometry (MS). However, in most SRM-MS biomarker validation studies the sample size is very small, and in particular smaller than the number of proteins measured in the …
-
Mass spectrometry, mechanisms, and molecular models - combining research in mass spectrometric reaction monitoring and chemical education
… combines work in the areas of mass spectrometric reaction monitoring and chemical education. In the first part of this thesis, real-time mechanistic analysis using electrospray ionization mass spectrometry is reported. In Chapter 1, an introduction to the mass spectrometric instrumentation and …
-
ΑΝΑΠΤΥΞΗ ΕΦΑΡΜΟΓΩΝ LC-MS/MS (MRM – MULTIPLE REACTION MONITORING) ΜΕΘΟΔΟΛΟΓΙΩΝ ΣΕ ΔΕΙΓΜΑΤΑ ΠΛΑΣΜΑΤΟΣ ΓΙΑ ΤΗΝ ΠΡΟΒΛΕΨΗ ΚΑΡΔΙΑΓΓΕΙΑΚΩΝ ΝΟΣΗΜΑΤΩΝ
ΣΚΟΠΟΣ: Τα καρδιαγγειακά νοσήματα αποτελούν την κύρια αιτία θανάτου παγκοσμίως. Για τον λόγο αυτό, υπάρχει κλινική ανάγκη για μια προγνωστική μέθοδο με αυξημένη ακρίβεια και ευαισθησία. Στόχος της παρούσας εργασίας είναι η εφαρμογή της τεχνικής LC-MS/MS (MRM) για την ανάπτυξη μεθοδολογιών για τη …
-
Ανάπτυξη LC-MS/MS (MRM-Multiple Reaction Monitoring) μεθοδολογιών σε δείγματα πλάσματος για την πρόβλεψη της εξέλιξης της Χρόνιας Νεφρικής Νόσου (ΧΝΝ)
Η Χρόνια Νεφρική Νόσος (ΧΝΝ) αποτελεί ένα μείζον πρόβλημα της δημόσιας υγείας. Η διάγνωση της ΧΝΝ βασίζεται σήμερα στην ανίχνευση της μείωσης του εκτιμώμενου ρυθμού σπειραματικής διήθησης (eGFR) και/ή της παρουσίας αλβουμινουρίας. Ωστόσο, αυτοί οι δείκτες έχουν σοβαρούς περιορισμούς στην αξιολόγηση …
-
Part One: A Flow Reactor With In-Line Analytics: Design and Implementation Part Two: In-Line Derivatization of Protic Compounds for GC/MS Reaction Monitoring
The creation of an automated synthetic reaction system with in-line analytics is presented in two parts. First, the design and implementation of a flow reactor system complete with in-line gas chromatography mass spectrometry (GC/MS) analytical instrument is discussed. The testing and validation of …
-
Development of a multiple reaction monitoring liquid chromatography tandem mass spectrometry method for the simultaneous determination of five antiretroviral drugs in human blood plasma-a contrast of extraction efficiencies using selected sample preparation techniques
A multiple reaction monitoring liquid chromatography - tandem mass spectrometry (MRM LC-MS/MS) method for the simultaneous determination of antiretroviral drugs (Emtricitabine, Tenofovir, Efavirenz, Lopinavir and Retonavir) in sterilized human blood plasma was developed for therapeutic drug …
-
Monitoring complex reactions using tandem mass spectrometric methods
… ion scan, neutral loss scan (NLS) and multiple reaction monitoring (MRM) MS/MS methods were applied. Tetrakistriphenylphosphine palladium(0) was the catalyst of this reaction and a positively charged phosphonium aryl iodide tag (m/z 478) was implemented into the first catalytic cycle, enabling …
-
Analysis Strategies for Bioactive, Polar Fatty Amides in Complex Samples
… pertaining to method development of multiple reaction monitoring detection of these species. Chromatographic separation methods of fatty acyls, with a focus on primary fatty acid amides and N-acyl glycines, are outlined in chapter 3 and these results are used to develop a two dimensional …
Page 1 of 16