Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 109 for “"Readout electronics"”.

  1. Readout electronics for microbolometer infrared focal plane array

    … self-heating effect that will greatly affect the readout circuits. This project looks into a new self-heating cancellation technique and applies it to the readout integrated circuits (ROIC) for the microbolometer IR FPA. Such a cancellation scheme based on the equivalence between the electrical …

    nus Repository record for Readout electronics for microbolometer infrared focal plane array (opens in a new tab) Download file for Readout electronics for microbolometer infrared focal plane array (opens in a new tab)

  2. Test of New Readout Electronics for the BONuS12 Experiment

    … as low as 70 MeV/c. The new RTPC will use a new readout electronic system, which is also used by other trackers in CLAS12. This thesis will present the first tests of this electronics using a previously built RTPC of similar design.

    odu Repository record for Test of New Readout Electronics for the BONuS12 Experiment (opens in a new tab)

  3. Design and test of readout electronics for medical and astrophysics applications

    … the sensor, the data moves through the front-end electronics for being readout and collected, ready for the data manipulation. After this general section, the thesis describes the results achieved in two projects developed by the collaboration between the medical physics group of the University of …

    poli-torino Repository record for Design and test of readout electronics for medical and astrophysics applications (opens in a new tab)

  4. Integration of a high sensitivity MEMS directional sound sensor with readout electronics

    … device utilizing commercial-off-the-shelf readout electronics with the biologically inspired sensor. An analysis of previously used techniques is presented along with a novel fully-integrated miniaturized design. Specific investigations include integration with external readout electronics, …

    nps Repository record for Integration of a high sensitivity MEMS directional sound sensor with readout electronics (opens in a new tab)

  5. Target ASIC-Based Data Acquisition System for the Readout Electronics of the Watchman Detector

    … that a TARGET solution will satisfy WATCHMAN's readout requirements. The TARGETC FMC Prototype is a cost-effective data acquisition system that can handle a large number of photomultiplier tubes while digitizing the signals at a high sampling rate. The system uses the TARGETC ASIC, developed by …

    hawaii Repository record for Target ASIC-Based Data Acquisition System for the Readout Electronics of the Watchman Detector (opens in a new tab)

  6. Improved N-Type 4h-Sic Epitaxial Layer Radiation Detectors and Noise Analysis of Front-End Readout Electronics

    … of 22.6%. Electronic noise analysis of front-end readout system was carried out in terms of equivalent noise charge (ENC) in order to study the contribution of white series noise, pink noise ( parallel and ⁄ series) and white parallel noise to the total electronic noise in the detection system. …

    south-carolina Repository record for Improved N-Type 4h-Sic Epitaxial Layer Radiation Detectors and Noise Analysis of Front-End Readout Electronics (opens in a new tab)

  7. Study and design of the front-end and readout electronics for the tracking plane in the NEXT experiment

    … thesis is focused on the study and design of the electronics involving the tracking plane, which includes some technical solutions related also with mechanical issues. From the sensors placed inside the detector, the SiPMs, to the front-end electronic boards, there are few elements on the chain; …

    upv Repository record for Study and design of the front-end and readout electronics for the tracking plane in the NEXT experiment (opens in a new tab)

  8. Calibration of the readout electronics for the ATLAS NSW project and position resolution of large-scale micromegas detectors

    Während des sogenannten Long Shutdown 2 wurde die innerste Endkappe des Myon Spektrometers des ATLAS Detektors am Large Hadron Collider am CERN durch das ”neue kleine Rad” (New Small Wheel, NSW) ersetzt. Es wurde entwickelt um in das Level-1 Triggersystem integriert zu werden und um Präzi- …

    freiburg-diss Repository record for Calibration of the readout electronics for the ATLAS NSW project and position resolution of large-scale micromegas detectors (opens in a new tab)

  9. DEMONSTRATOR SYSTEM FOR THE PHASE-I UPGRADE OF THE TRIGGER READOUT ELECTRONICS OF THE ATLAS LIQUID ARGON CALORIMETERS AT THE LHC

    … electromagnetic calorimeter Phase-I trigger electronics. The main topic of my doctoral project is the implementation of VHDL firmware for the Field Programmable Gate Arrays (FPGAs) of the new calorimeter trigger electronics. I spent the first of the three Ph.D. years working in Milano and the …

    milano Repository record for DEMONSTRATOR SYSTEM FOR THE PHASE-I UPGRADE OF THE TRIGGER READOUT ELECTRONICS OF THE ATLAS LIQUID ARGON CALORIMETERS AT THE LHC (opens in a new tab)

  10. Simulation of the upgraded Phase-1 Trigger Readout Electronics of the Liquid-Argon Calorimeter of the ATLAS Detector at the LHC

    … of increased luminosity, a revision of the data readout electronics of the Liquid-Argon-Calorimeter of the ATLAS detector is scheduled. This is required to retain the efficiency of the trigger at increased event rates despite its fixed bandwidth. The focus lies on the early digitization and finer …

    qucosa-diss

  11. Development of a readout system for the TOP detector for Belle II at SuperKEKB

    This thesis details the development of the readout electronics for the Time-of-Propagation (TOP) detector system, part of the Belle II detector located at the interaction point of the SuperKEKB electron-positron collider in Tsukuba, Japan.

    hawaii Repository record for Development of a readout system for the TOP detector for Belle II at SuperKEKB (opens in a new tab)

  12. Characterization of high resistivity GaAs as sensor material for photon counting semiconductor pixel detectors

    … In so-called hybrid detectors, a pixelated readout electronics, which processes the charge signal created in the sensor and provides analyzable data, is connected to a suitable sensor material via small solder bumps. Thus, besides the ongoing development of the readout electronics itself …

    freiburg-diss Repository record for Characterization of high resistivity GaAs as sensor material for photon counting semiconductor pixel detectors (opens in a new tab)

  13. Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications

    … of channels of high perfonnance detector readout electronics. The Phase I ASIC was developed in 1992 to reduce the cost, power consumption and complexity of PET systems and to improve reliability. The Phase I ASIC has been very successful and is a key component in thousands of commercial …

    utk-theses Repository record for Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications (opens in a new tab)

  14. Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications

    … of channels of high perfonnance detector readout electronics. The Phase I ASIC was developed in 1992 to reduce the cost, power consumption and complexity of PET systems and to improve reliability. The Phase I ASIC has been very successful and is a key component in thousands of commercial …

    utk-theses Repository record for Design and analysis of an attenuator-based, four-channel, differential, 150 MHz, linear-in-dB VGA with sub-nanosecond delay dispersion for PET applications (opens in a new tab)

  15. A position-sensing system for the top PMT array in the LUX-ZEPLIN dark matter experiment

    … created a novel feedback circuit for the sensor readout electronics, designed to suppress the effect of the cable capacitance.</p> <p>To monitor precisely the position of the PMT array with respect to the cryostat vessel, we will use six position sensors mounted as a Gough-Stewart Platform …

    oxford Repository record for A position-sensing system for the top PMT array in the LUX-ZEPLIN dark matter experiment (opens in a new tab)

  16. Integrated reference circuits for low-power capacitive sensor interfaces

    … the work describes the typical integrated readout electronics of a capacitive sensor on the functional level. The readout electronics can be divided into four different functional parts, namely the sensor readout itself, signal post-processing, references, and power management. Before the …

    aalto Repository record for Integrated reference circuits for low-power capacitive sensor interfaces (opens in a new tab)

  17. Experimental study of semitauonic B_c decays and development of the Upstream Tracker electronics for the LHCb upgrade

    … topic of this dissertation is the development of readout electronics for a new silicon-strip tracking detector, the Upstream Tracker, to upgrade the LHCb detector. The upgraded LHCb detector will collect much more data in the upcoming runs of the Large Hadron Collider.

    maryland Repository record for Experimental study of semitauonic B_c decays and development of the Upstream Tracker electronics for the LHCb upgrade (opens in a new tab)

  18. Design and Implementation of an Integrated Biosensor Platform for Lab-on-a-Chip Diabetic Care Systems

    … stringent performance constraints on sensor readout architecture. In glucose sensing for diabetic patients, portable handheld devices are common, and have demonstrated significant performance improvement over the last decade. Fluctuations in glucose levels with patient physiological …

    utk-theses Repository record for Design and Implementation of an Integrated Biosensor Platform for Lab-on-a-Chip Diabetic Care Systems (opens in a new tab)

Page 1 of 6