Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Reagent delivery"”.

  1. A field and Numerical Investigation of the Pressure Pulsing Reagent Delivery Approach

    … using a conventional or continuous pressure delivery approach and an injection using a pressure pulsing instrument. The underlying motivation was to identify engineering opportunities presented by pressure pulsing with the potential to improve remediation efficiency at contaminated sites. A …

    waterloo Repository record for A field and Numerical Investigation of the Pressure Pulsing Reagent Delivery Approach (opens in a new tab)

  2. Improved Methods Of Transgenic And Viral Reagent Delivery For Genome Engineering In Plants

    … for plant breeding, however, depends on robust delivery and activity of molecular reagents into and within regenerable cells, in order to produce stably modified germplasm. This remains a significant barrier for the majority of plants. In this thesis, I present research at the intersection of …

    umn Repository record for Improved Methods Of Transgenic And Viral Reagent Delivery For Genome Engineering In Plants (opens in a new tab)

  3. Investigation of Reagent Delivery Formats and Implications for Higher-sensitivity Detection in Paper-based Diagnostics

    … Using the same system, assays based on two delivery formats, sequential delivery of analyte and colorimetric label and premixed one step delivery were characterized for reproducibility, sensitivity, and time to result. The sequential delivery format offers the potential for higher …

    washington Repository record for Investigation of Reagent Delivery Formats and Implications for Higher-sensitivity Detection in Paper-based Diagnostics (opens in a new tab)

  4. Increased sensitivity for lateral flow immunoassays through signal amplification methods

    … with a commercially available kit. Since reagent delivery format is also a key factor to improve the sensitivity, we investigated two formats: premixed and sequential delivery. An improved reagent delivery format achieved better assay sensitivity. To elucidate the underlying mechanism …

    washington Repository record for Increased sensitivity for lateral flow immunoassays through signal amplification methods (opens in a new tab)

  5. Simultaneous Part-Per-Billion Determination of Sodium and Chloride Ions

    … The preconcentrator system is loaded using a reagent delivery module operated for a specific time at a preset flow rate. Total injection volumes of 2-5 ml are routinely used. Various chromatograms are discussed along with detailed information concerning detection limits for sodium and …

    unt Repository record for Simultaneous Part-Per-Billion Determination of Sodium and Chloride Ions (opens in a new tab)

  6. Developing Methods To Overcome The Bottlenecks In Plant Gene Editing

    … typically performed by delivering gene editing reagents (e.g. Cas9 and sgRNAs) to explants in culture. Edited cells are induced to differentiate into whole plants by exposure to various hormone regimes. This process serves as a major bottleneck in current plant biological studies since creating …

    umn Repository record for Developing Methods To Overcome The Bottlenecks In Plant Gene Editing (opens in a new tab)

  7. Developing Low-Cost Paper-Based Assays to Reduce Overtreatment at the Point of Care

    … of paper membranes to sequentially drive reagents for immunoassay binding reactions. By automating reagent delivery, these tests minimize hands-on time and result turnaround time to minimize training requirements and allow for timely decision-making. These tests will enable better …

    rice Repository record for Developing Low-Cost Paper-Based Assays to Reduce Overtreatment at the Point of Care (opens in a new tab)

  8. Taming The Halogens Using Metal–Organic Frameworks

    … are often toxic gasses or prohibitively unstable reagents. Therefore, the bulk of my graduate research has focused on the development of novel materials for the safe handling of the halogens, imparting tunable synthetic control and thus “taming” their reactivity. These materials, metal-organic …

    cornell Repository record for Taming The Halogens Using Metal–Organic Frameworks (opens in a new tab)

  9. Applications of micro-3D printing to microfluidic cell dosing

    … by exposing entire culture dishes to a desired reagent. While the addition of soluble reagents homogenously to cell culture dishes provides a basis for understanding much of cell biology, greater spatial resolution of reagent delivery is necessary in order to elucidate mechanisms on the …

    texas Repository record for Applications of micro-3D printing to microfluidic cell dosing (opens in a new tab)

  10. Treatment of a PHC Source Zone using Land Application of Sulfate

    … sulfate dosage system that would satisfy the reagent delivery and remediation requirements. Three episodes of sulfate release (5 m3 of 5-20 g/L Na2SO4, and 0.3 g/L (NH4)2SO4) at the ground surface were conducted over an 8-month period. A host of multilevel monitoring wells in conjunction with …

    waterloo Repository record for Treatment of a PHC Source Zone using Land Application of Sulfate (opens in a new tab)

  11. Integrating paper fluidic liquid handling and whole blood plasma separation into silicon photonic biosensors.

    … rely on external pumps to deliver samples and reagents over the photonic sensors. To increase the clinical viability of this technology, this project seeks to dramatically reduce the complexity of the bio-sensing system by integrating sample processing and fluidics via a capillary driven …

    washington Repository record for Integrating paper fluidic liquid handling and whole blood plasma separation into silicon photonic biosensors. (opens in a new tab)

  12. Microfluidic Tools for Studying Development in Embryos and Brain Organoids

    … magnification imaging, parallelization, rapid reagent delivery and exchange and lower reagent consumption. Hence, this thesis sought to address high content screening challenges that affect the study of development in two multicellular systems: C. elegans embryos and brain organoids. This …

    gatech Repository record for Microfluidic Tools for Studying Development in Embryos and Brain Organoids (opens in a new tab)

  13. Microfluidic-based Tools to Investigate Gene Expression and Regulation with Tissue-specificity during Aging in Caenorhabditis elegans

    … hybrid device to enhance the reagent delivery of large, charged macromolecules. The second platform uses gentler reagents and allows for robust multicycle smFISH while retaining the tissue integrity of the samples. In Aim 3, I correlate age-related changes in neuronal …

    gatech Repository record for Microfluidic-based Tools to Investigate Gene Expression and Regulation with Tissue-specificity during Aging in Caenorhabditis elegans (opens in a new tab)

  14. World-to-digital microfluidics for transformation and enzymatic assays

    … that are integrated with the DMF device: reagent delivery and temperature control. This new platform enables us to perform a variety of biological or chemical experiments on a chip with reduced manual intervention. Specifically, the new platform enabled an increase in reservoir volume on …

    concordia Download PDF for World-to-digital microfluidics for transformation and enzymatic assays (opens in a new tab)

  15. Transgene-free Genome Editing in Poplar

    … due to limitations in transformation efficiency, delivery methods, and regulatory concerns. In this study, we developed and evaluated genome editing strategies to optimize transgene-free genome editing in Populus tremula × alba. We compared the performance of two CRISPR-Cas9 base editor vector …

    maryland Repository record for Transgene-free Genome Editing in Poplar (opens in a new tab)

  16. Construction, evaluation, and use of a fluoroimmunochemical-based fiber optic microscale regenerable biosensor

    … specificity and selectivity of immunological reagents with fiber optic transmission of spectral signals, the area of fluoroimmunoassay-based fiber optic chemical sensors has grown considerably in the last several years. Building on past work within this research group, a new sensor (the …

    utk-theses Repository record for Construction, evaluation, and use of a fluoroimmunochemical-based fiber optic microscale regenerable biosensor (opens in a new tab)

  17. Microfluidic flow rate sensing and control : from portable systems to chip-scale implementations

    … control over chemical reactions, reduces reagent consumption, and improves the overall sensitivity of diagnostic assays. Traditional commercial flow control systems, however, often rely on bulky and expensive setups, which limit their portability and adaptability. The system-level work …

    ubc Repository record for Microfluidic flow rate sensing and control : from portable systems to chip-scale implementations (opens in a new tab) Download PDF for Microfluidic flow rate sensing and control : from portable systems to chip-scale implementations (opens in a new tab)

  18. Development of RNA Viral Vectors for Plant Genome Engineering

    … the desired modification at the target site and delivery of the reagents to plant cells. RNA guided endonucleases, such as CRISPR/Cas9, have enabled an unprecedented ability for site-specific genetic modification. Delivery of reagents, however, is still largely reliant on tissue culture …

    umn Repository record for Development of RNA Viral Vectors for Plant Genome Engineering (opens in a new tab)

  19. Development of a field portable mass spectrometer for quantitative analysis of volatile organic compounds in air

    … of an in-line liquid chemical ionization reagent delivery system is presented and proposed as an e ective strategy for eliminating interferences arising from biogenic terpenes and alkyl aromatics. In all, this thesis presents the design and implementation of a mobile membrane introduction …

    uvic Repository record for Development of a field portable mass spectrometer for quantitative analysis of volatile organic compounds in air (opens in a new tab)

  20. Built to Share: Modular Design Tools for Accessible Microfluidics and Decentralized Diagnostics

    … for sequential fluid routing and SCMs for reagent resuspension, into printable forms compatible with low-cost LCD 3D printers. I characterize their operation, identify design constraints imposed by printer resolution, and validate performance in fluid routing and pulse-shaped reagent …

    washington Repository record for Built to Share: Modular Design Tools for Accessible Microfluidics and Decentralized Diagnostics (opens in a new tab)

Page 1 of 2