Results 1 to 20 of 39 for “"Real-Time MRI"”
-
Advanced real-time MRI-guided cardiac catheterisation
… past two decades, Magnetic Resonance Imaging (MRI)-guided cardiac catheterisation has emerged as a safer, non-ionising alternative, offering superior soft tissue contrast and haemodynamic data. During procedures, MRI is utilised for guiding navigation via real-time imaging and for both …
-
Real-time MRI of Moving Spins Using Undersampled Radial FLASH
… when studied using magnetic resonance imaging (MRI). Moving spins define many functional characteristics of the human body such as diffusion, perfusion and blood flow. Quantitative MRI of moving spins can provide valuable information about the human physiology or of a technical system. In …
-
Developing Real-time MRI Using Simultaneous Multislice Acceleration and Compressed Sensing
Real-time MRI (rtMRI) is an imaging method which allows motion to be recorded at high temporal and spatial resolutions without the need for synchronization equipment or assumptions regarding periodicity of motion. This has a wide range of applications such as studying the dynamics of speech, …
-
Catheter Insertion Mechanism for Real-Time MRI-Guided Robotic Assisted Cardiac Ablation
… in image quality. The implementation of a real-time MRI-guided robotic-assisted catheter ablation system can eliminate radiation exposure, provide superior guidance, reduce inter-operator variability, and could result in increased success rates in the treatment of Afib. Such a system is …
-
Load-Independent And Regional Measures Of Cardiac Function Via Real-Time Mri
… AND REGIONAL MEASURES OF CARDIAC FUNCTION VIA REAL-TIME MRI Francisco Jose Contijoch Robert C Gorman, MD Expansion of infarcted tissue during left ventricular (LV) remodeling after a myocardial infarction is associated with poor long-term prognosis. Several interventions have been developed to …
-
Real-time mri in two orthogonal slices for therapy monitoring and interventional guidance
MRI guidance can enhance lesion detection and procedural accuracy during therapeutic interventions. Commonly, fast T1-weighted or T2/T1-weighted gradient echo sequences are used for MR guidance due to their high temporal resolution; however, T2-weighting can provide enhanced tumor visualization. …
-
A Machine Learning Approach to Real-time MRI Guidance for Robotic Needle-Based Procedures
… to aid needle insertion under intermittent MRI-guidance. To realize the full potential of image-guided robotics, there is a need to integrate with real-time imaging for feedback during insertion.This work describes a novel data-driven approach to the integration of real-time imaging for the …
-
Real-time organ motion management in MRI-guided radiotherapy
… radiotherapy devices is equipped with on-board MRI scanners to visualize the internal organ motion of patients in real time during radiation delivery. The cine MRI acquired during radiation delivery provides an opportunity to learn the patient-specific anatomical trajectory, which, in turn, can …
-
Teleoperated MRI‐Guided Prostate Needle Placement
Most robotic systems reported for MRI-guided prostate interventions use manual needle insertion, based on a previously acquired image, which requires withdrawing the patient from the scanner multiple times during the procedure. This makes the intervention longer, more expensive and elongating the …
-
NON-CARTESIAN MAGNETIC RESONANCE IMAGING STRATEGIES: IMPROVEMENTS IN ACCELERATED CARDIAC MAGNETIC RESONANCE IMAGING AND TECHNICAL CONSIDERATIONS
Magnetic Resonance Imaging (MRI) is a medical imaging modality that is essential for the imaging of heart because of its unparalleled soft tissue contrast and lack of ionizing radiation. However, the dynamic nature of the heart, together with the motion introduced by respiration, make it a …
-
Visual Force-Feedback Interfacing for Image-guided Telemanipulated Robotic Surgical Systems
… Among the procedures, which can benefit from real-time guidance are robot-assisted intracardiac interventions, such as valvuloplasties, on the beating heart. In this work, we propose an approach for the integration of real-time MRI with the telemanipulated surgical setup and the processing of …
-
Towards mri-guided cardiovascular interventions
… inherent vascular and soft-tissue contrast of MRI make it an appealing imaging modality to guide cardiovascular interventional procedures. Advances in real-time MRI have made MRI-guided procedures a realistic possibility. The MR environment, however, introduces additional challenges to the …
-
The functional anatomy of sucking and swallowing in breastfeeding infants
… in a prospective observational study, we used real-time MRI to image breastfeeding in 12 normal infants. We then reviewed 48 flexible endoscopic evaluation of swallowing (FEES) performed on breastfeeding infants referred for noisy breathing, difficulty feeding and/or concerns regarding possible …
-
Towards MRI-Guided and Actuated Tetherless Milli-Robots
… cost effectiveness. Magnetic Resonance Imaging (MRI) is used for pre-operative planning and is also investigated for realtime intra-operative guidance. A new type of technology is emerging that uses the magnetic-field gradients of the MR scanner to maneuver ferromagnetic agents for local delivery …
-
Analysis of Cartesian and projection (K,T)-space sampling patterns when using the partially separable functions model for cardiac perfusion MR imaging
Cardiac perfusion MRI aims to analyze perfusion characteristics of the heart through the injection of a contrast agent. In clinical practice, cardiac perfusion imaging is used to diagnose ischemic myocardial tissue, coronary artery disease, and, to a lesser extent, myocardial infarctions. To …
-
A hardware reconstruction system for real-time magnetic resonance imaging via 2D FFT or filtered backprojection
A "real-time" hardware reconstruction system for Magnetic Resonance Imaging (MRI) has been designed, constructed, and demonstrated. Here, "real-time" corresponds to frame rates of 30 or more per second (i.e., video rate). The system is capable of reconstructing images via either the 2D FFT …
-
Development of A Gadolinium-Based Nanotheranostics Platform for Irradiation Activatable MRI-Radiosensitization and Doxorubicin Release in Cancer Therapy
… doxorubicin delivery and simultaneous MRI- radiosensitization for synergistic cancer therapy, targeting breast cancer treatment. As shown in the diagram, once these nanocomplexes enter into tumour sites through the EPR (enhanced permeability and retention) effect, an external radiation …
-
Novel data-driven analysis methods for real-time fMRI and simultaneous EEG-fMRI neuroimaging
Real-time neuroscience can be described as the use of neuroimaging techniques to extract and evaluate brain activations during their ongoing development. The possibility to track these activations opens the doors to new research modalities as well as practical applications in both clinical and …
-
Real-Time Kinematic Modeling of Magnetically-Actuated MRI-Guided Robotic Intravascular Cardiac Catheter
… and control of the magnetically-actuated MRI-guided robotic intravascular cardiac catheter. The robotic catheters are embedded with current carrying coil actuators. The actuator contains one axial coil, and two orthogonal side coils. The catheter is steered by the magnetic moments …
-
MR-Guided Assessment and Management of Ventricular Tachycardia
… a newly-developed magnetic resonance imaging (MRI) electrophysiology system. In electrophysiology (EP), radiofrequency (RF) catheter ablation combined with cardioverter-defibrillator implantation is a first-line action to manage ventricular VT. Unfortunately, this therapy is known to have …