Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 286 for “"Reference method"”

  1. Evaluation of Federal Reference Method PM10 Inlet for Sampling Large Particles

    … PM NAAQS is monitored using networks of Federal Reference Method (FRM) designated PM10 sampling inlets. Several previous studies have suggested that FRM PM10 inlets sampling PM from rural sources will not perform as designed and that a significant number of particles with larger diameters will …

    tamu Repository record for Evaluation of Federal Reference Method PM10 Inlet for Sampling Large Particles (opens in a new tab)

  2. Nonlinear controller design using universal approximators through the virtual reference method

    … dynamical systems in the context of the Virtual Reference Feedback Tuning. One of the challenges in the utilization of the VRFT method is the definition of the controller parametrization. Since nonlinear systems present a very rich behavior, defining a parametrization that allows to approximate …

    brazil-ufrgs Repository record for Nonlinear controller design using universal approximators through the virtual reference method (opens in a new tab)

  3. Design of nonlinear controllers through the virtual reference method and regularization

    … nonlinear formulation of the data-driven control method known as the Nonlinear Virtual Reference Feedback Tuning. When the process to be controlled contains a significant quantity of noise, the standard Nonlinear VRFT approach – that uses the Least Squares method – yield estimates with poor …

    brazil-ufrgs Repository record for Design of nonlinear controllers through the virtual reference method and regularization (opens in a new tab)

  4. The modal method : a reference method for modeling of the 2D metal diffraction gratings

    Les éléments de diffraction sont largement utilisés aujourd'hui dans un nombre grandissant d'applications grâce à la progression des technologies de microstructuration dans le sillage de la micro-électronique. Pour un design optimal de ces éléments, des méthodes de modélisation précises sont …

    star-france Repository record for The modal method : a reference method for modeling of the 2D metal diffraction gratings (opens in a new tab)

  5. DEVELOPMENT OF A REFERENCE METHOD FOR THE ABSOLUTE MEASURING OF FLUORESCENCE IN BIOLOGICAL ANALYSIS

    … research presented here was aimed to develop a method traceable to SI to compare the absolute fluorescence intensity measured by different instruments. This is due to the fact that the most common instruments use arbitrary measurement units. Each measure strictly depends on the technical …

    poli-torino Repository record for DEVELOPMENT OF A REFERENCE METHOD FOR THE ABSOLUTE MEASURING OF FLUORESCENCE IN BIOLOGICAL ANALYSIS (opens in a new tab)

  6. Development of a reference method for ventilation rate measurements in a naturally ventilated test facility

    … ventilated animal houses, no generally accepted reference technique exists to measure the airflow rate. Most existing techniques fail to account for the heterogeneous airflow patterns caused by the constantly changing external conditions of wind speed and direction. A new measuring method was …

    ghent Repository record for Development of a reference method for ventilation rate measurements in a naturally ventilated test facility (opens in a new tab)

  7. The evaluation of PM2.5 measurements by Federal Reference Method (FRM) and Continuous instruments in Cincinnati, Ohio

    The filter based methods have been “the gold standard” of PM measurement in spite of its cost and labor intensiveness. Meanwhile many continuous instruments have been employed side by side at many US sites, and the results from the continuous instruments have been used in forecasting air quality …

    ohiolink Repository record for The evaluation of PM2.5 measurements by Federal Reference Method (FRM) and Continuous instruments in Cincinnati, Ohio (opens in a new tab)

  8. Comparison Between Tapered Element Microbalance (TEOM) and Federal Reference Method (FRM) for PM<sub>2.5</sub> Measurement in East Tennessee

    … Microbalance Monitors (TEOM) and the Federal Reference Method (FRM). The difference is generally related to lower ambient temperatures (i.e., at lower temperatures, the TEOM has been cited to under report PM2.5 concentrations).</p> <p>To determine if this same relationship exists in East …

    ut-knoxville Repository record for Comparison Between Tapered Element Microbalance (TEOM) and Federal Reference Method (FRM) for PM<sub>2.5</sub> Measurement in East Tennessee (opens in a new tab)

  9. Development of a reference method based on the fast multipole boundary element method for sound propagation problems in urban environments : formalism, improvements & applications

    Décrit comme l'un des algorithmes les plus prometteurs du 20ème siècle, le formalisme multipolaire appliqué à la méthode des éléments de frontière, permet de nos jours de traiter de larges problèmes encore inconcevables il y a quelques années. La motivation de ce travail de thèse est d'évaluer la …

    star-france Repository record for Development of a reference method based on the fast multipole boundary element method for sound propagation problems in urban environments : formalism, improvements & applications (opens in a new tab)

  10. Estimation of whole body muscle, adipose/fat mass, validation in health and during weight loss. Development of prediction equations using MRI as reference method

    … Anthropometry offers a practical and inexpensive method for muscle and fat estimation in clinical and epidemiological settings; however, its use is imperfect due to many limitations, such as a shortage of reference data, misuse of terminology, unclear assumptions, and the absence of properly …

    glasgow Repository record for Estimation of whole body muscle, adipose/fat mass, validation in health and during weight loss. Development of prediction equations using MRI as reference method (opens in a new tab)

  11. Comparison of thermal process evaluation methods for conduction heating foods in cylindrical containers

    Five formula methods and three numerical general methods for determining thermal process lethality were compared with a reference method to demonstrate their applicability to conduction heating foods in cylindrical containers. Hypothetical centerpoint temperature history curves for cans with height …

    ubc Repository record for Comparison of thermal process evaluation methods for conduction heating foods in cylindrical containers (opens in a new tab)

  12. Development of reference methods and reference materials for trace level antibiotic residues in food using IDMS

    … traceability of measurement results, reference methods and certified reference materials (CRMs) are needed. Nitrofuran antibiotic drugs used for the treatment of bacterial and protozoan infections in animals were studied in this thesis. A high accuracy reference method and an …

    unsw Repository record for Development of reference methods and reference materials for trace level antibiotic residues in food using IDMS (opens in a new tab)

  13. Biochemical characteristics of inconsistent free T₄ assays

    … and protein-bound T4 concentrations. A free T4 reference method using direct equilibrium dialysis radioimmunoassay has been well characterized. New experiments have applied this equilibrium dialysis reference method and a well characterized total T4 immunoassay to the characterization of eight …

    loma-linda Repository record for Biochemical characteristics of inconsistent free T₄ assays (opens in a new tab)

  14. Separation of the Heat Transfer Components for Diffusion Flames Impinging onto Ceilings

    … and an aspirated Type K thermocouple. Four methods of calculating the convective heat transfer coefficient, h, were developed and adapted; two reference methods and two slope methods. The components of heat transfer at the impingement point were separated using these calculated h values. The …

    vt Repository record for Separation of the Heat Transfer Components for Diffusion Flames Impinging onto Ceilings (opens in a new tab)

  15. Developing a blood glucose meter-based method for the rapid detection of lactose in dairy ingredients

    … ingredients. The proposed BGM lactose analysis method involves diluting a sample to an appropriate level with buffer, adding lactase enzyme, incubating at 40°C for 15 minutes, and measuring the resulting glucose content with the BGM. A calibration curve developed between the known lactose …

    ksu Repository record for Developing a blood glucose meter-based method for the rapid detection of lactose in dairy ingredients (opens in a new tab)

  16. Validity of six field and laboratory methods for measurement of body composition in 10-14 year old boys

    … the following six body composition measurement methods against a 3-component reference method: total body water (TBW) by isotope dilution; air displacement plethysmography (BODPOD); estimation from body density using BODPOD; skinfold thickness using Slaughter equations; whole body bioelectrical …

    glasgow Repository record for Validity of six field and laboratory methods for measurement of body composition in 10-14 year old boys (opens in a new tab)

  17. Plasma clearance of iohexol simplified by dried blood spot testing.

    … are inaccurate, or measured with gold standard methods, which are reliable but unpractical. We propose to simplify the plasma clearance of iohexol, a gold standard method to measure renal function, measuring iohexol in dried blood spot samples (DBS). Methods: We compared GFR values assessed by …

    ull Repository record for Plasma clearance of iohexol simplified by dried blood spot testing. (opens in a new tab)

Page 1 of 15