  1. A Photoionization Reflectron Time-of-Flight Investigation of Phosphorus Chemistry in Extraterrestrial Ices

    … mass spectrometry (QMS), tunable-photoionization reflectron time-of-flight mass spectrometry (PI-ReTOF-MS), and infrared spectroscopy (FTIR) in addition to ex situ analysis by secondary-ion mass spectrometry (SIMS) and two-dimensional gas chromatography mass spectrometry (GC×GC-TOF-MS), the …

    hawaii Repository record for A Photoionization Reflectron Time-of-Flight Investigation of Phosphorus Chemistry in Extraterrestrial Ices (opens in a new tab)

  2. The Application of MALDI and Tandem Reflectron TOF Mass Spectrometry to the Analysis of Biomolecular Ions

    … with primary objective of developing a tandem reflectron time-of- flight mass spectrometer for the studies of laser photodissociation of molecular ions. Chapter 1 presents a brief review of the techniques involved in my research work, such as resonance ionisation spectroscopy (RIS), …

    glasgow Download PDF for The Application of MALDI and Tandem Reflectron TOF Mass Spectrometry to the Analysis of Biomolecular Ions (opens in a new tab)

  3. MALDI and SIMS microscope mode imaging mass spectrometry

    … ion mass spectrometry (SIMS).</p> <p>Using a reflectron ToF mass spectrometer, by generating a stronger field, the spatial resolution can be increased from 13 ± 1 μm o 8 ± 1 μm experimentally, and could potentially reach <7 μm according to simulations. Variable magnification has been explored …

    oxford Repository record for MALDI and SIMS microscope mode imaging mass spectrometry (opens in a new tab)

  4. Development of high-throughput imaging mass spectrometry

    … <p>An ion microscope, incorporating a reflectron, was used to simultaneously image mass-resolved ions generated from a 0.3mm diameter surface. Mass and spatial resolutions of 8100±700m/Δm and 14 μm were obtained by using post extraction differential acceleration (PEDA) ion optical …

    oxford Repository record for Development of high-throughput imaging mass spectrometry (opens in a new tab)

  5. Improving the performance of microscope mass spectrometry imaging

    … than the original PEDA method.</p> <p>Although reflectrons are widely used to improve the mass resolving power of ToF-MS, incorporating them in a microscope MSI instrument is novel. A reflectron MSI instrument was designed and implemented. Simulations demonstrated that one-stage gridless …

    oxford Repository record for Improving the performance of microscope mass spectrometry imaging (opens in a new tab)

  6. BINDING ENERGIES AND SOLVATION OF ORGANIC MOLECULAR IONS, REACTIONS OF TRANSITION METAL IONS WITH, AND PLASMA DISCHARGE IONIZATION OF MOLECULAR CLUSTERS

    … the polymerization of acetylene done using the reflectron time of flight mass spectrometry and DFT calculations is also reported in this dissertation. We explain the variation in the observed trend in C-H/C-C activity of these ions. We also report the formation of carbide complexes by Zr+, Nb+, …

    vcu Repository record for BINDING ENERGIES AND SOLVATION OF ORGANIC MOLECULAR IONS, REACTIONS OF TRANSITION METAL IONS WITH, AND PLASMA DISCHARGE IONIZATION OF MOLECULAR CLUSTERS (opens in a new tab)

  7. Development of tandem time-of-flight instrumentation for the examination of prompt photodissociation of peptides using 193-nm radiation

    … of a decelerating/accelerating cell into a reflectron time-of-flight mass spectrometer is described for the examination of promptly-formed photodissociation products of peptide ions. The analytical utility of prompt 193-nm photodissociation was investigated for model peptides that resemble …

    tamu Repository record for Development of tandem time-of-flight instrumentation for the examination of prompt photodissociation of peptides using 193-nm radiation (opens in a new tab)

  8. Mass-Selected Ion-Molecule Cluster Beam Apparatus for Ultrafast Photofragmentation Studies (MICBAUPS)

    … clusters using linear-plus-quadratic reflectron mass spectrometer. We have carried out experiments on the CF3I∙I- ion-molecule cluster photoexcited by 266~nm UV femtosecond laser pulses to demonstrate the instrument performance. Anion fragments I- and CF3I- are detected along with …

    nebraska Repository record for Mass-Selected Ion-Molecule Cluster Beam Apparatus for Ultrafast Photofragmentation Studies (MICBAUPS) (opens in a new tab)

  9. Development of a quadrupole ion trap / time-of-flight mass spectrometer for mass resolution and ion photophysics

    … affecting mass resolutions in linear and reflectron time-of-flight modes are identified and possible improvements are discussed. An ion trap consisting of two endcaps and two ring flat electrodes is proposed and constructed on this basis. The newly optimized design is shown to yield the …

    unr Repository record for Development of a quadrupole ion trap / time-of-flight mass spectrometer for mass resolution and ion photophysics (opens in a new tab)

  10. The Study of Positive-Ion Mass Spectrometry of 5-Fluorouracil Using Low-Energy Electron Impact

    … with the molecules are extracted into a reflectron time-of-flight mass spectrometer. The field-free region and the reflector of the time-of-flight mass spectrometer are both located in the flight-tube. The reflector is positioned at the end of the flight-tube and directs the ions back …

    maynooth Download PDF for The Study of Positive-Ion Mass Spectrometry of 5-Fluorouracil Using Low-Energy Electron Impact (opens in a new tab)

  11. Study of Electron-Impact Induced Fragmentation of Thymine

    … and a deflection system for steering the beam. A reflectron time-of-flight mass spectrometer with a microchannel plate detector is used to detect and mass resolve the positively charged fragments. LabVIEW based data acquisition techniques are used to accumulate the time-of-flight data as a …

    maynooth Download PDF for Study of Electron-Impact Induced Fragmentation of Thymine (opens in a new tab)

  12. Spectroscopy of core-excited molecules and exploration of the induced dynamics

    … spectrometer types were used, an ion-trap with a reflectron mass spectrometer,hemispherical energy resolving electron analysers, and 3D momentum imaging spectrometers for charged particles.Results: X-ray absorption like spectra were obtained for new ions, CH+3 ,CH+4 , and CH+5 . The ionised …

    lund Repository record for Spectroscopy of core-excited molecules and exploration of the induced dynamics (opens in a new tab) Download PDF for Spectroscopy of core-excited molecules and exploration of the induced dynamics (opens in a new tab)

  13. Low-Energy Electron Impact Fragmentations of the Polycyclic Aromatic Hydrocarbon Anthracene

    … to form positively charged fragments. A reflectron time-of-flight mass spectrometer with a microchannel plate detector is used to mass-resolve and detect the fragment ions. A multichannel scaler card is used for acquiring single mass spectra. Data acquisition is controlled by LabVIEW …

    maynooth Download PDF for Low-Energy Electron Impact Fragmentations of the Polycyclic Aromatic Hydrocarbon Anthracene (opens in a new tab)

  14. Scaling Complexity in the Study of Radiation Damage in Biomolecules

    … Finally, the thesis presents an adapted reflectron time-of-flight mass spectrometry technique to analyse the metastable fragmentation and sequential fragmentation pathways. This revealed exceptionally rich metastable dissociation patterns of excited 3-aminophenol ions. We expect …

    the-open-u Download PDF for Scaling Complexity in the Study of Radiation Damage in Biomolecules (opens in a new tab)

  15. Study of Low Energy Electron-Impact Induced Ionization and Fragmentation of Uracil

    … fragments are mass resolved and detected using a reflectron time of flight mass spectrometer with a microchannel plate detecter. A multichannel scaler card is used for data acquisition. Code written in LabVIEW is used to control the electron impact energy and the acquisition of mass spectra as a …

    maynooth Download PDF for Study of Low Energy Electron-Impact Induced Ionization and Fragmentation of Uracil (opens in a new tab)

  16. Factors Affecting the Fragmentation of Peptide Ions: Metal Cationization and Fragmentation Timescale

    … the addition of a second source and a dual-stage reflectron are incorporated. The modifications result in improved mass range, signal-to-noise, and increased fragment ion collection efficiencies. High quality mass spectra are acquired across a range of mass-to-charge ratios from ~600 to 1900. …

    tamu Repository record for Factors Affecting the Fragmentation of Peptide Ions: Metal Cationization and Fragmentation Timescale (opens in a new tab)

  17. THE STUDY OF HYDROPHOBIC BIOMOLECULES WITH MATRIX ASSISTED LASER DESORPTION IONIZATION MASS SPECTROMETRY AND ATOMIC FORCE MICROSCOPY

    … Bruker, Bremen, Germany) in positive ion reflectron mode. Data were processed using FlexAnalysis 3.3 Software (Bruker). SCiLS Lab software (version 2024b, Bruker Daltonics, Billerica, MA, USA) was used for visualization and further analysis. Experiments were aimed at demonstrating that the …

    lsu-thes Repository record for THE STUDY OF HYDROPHOBIC BIOMOLECULES WITH MATRIX ASSISTED LASER DESORPTION IONIZATION MASS SPECTROMETRY AND ATOMIC FORCE MICROSCOPY (opens in a new tab)

  18. Spectral Measurements of Ionization and Dissociation in Intense Laser Pulses

    … 800 nm wavelength, 50 fs pulse duration with a reflectron time-of-flight (TOF) ion mass spectrometer. The formation of positively charged fragments ejected from acetonitrile at different laser intensities, between 4.4×10¹³ W/cm² and 3.3×10¹⁴ W/cm², and with various polarization orientations was …

    tamu Repository record for Spectral Measurements of Ionization and Dissociation in Intense Laser Pulses (opens in a new tab)

  19. Development of an Apparatus for the Study of Electron Impact Fragmentation of Molecular Clusters

    … Ionised fragments are detected using a reflectron time-of-flight mass spectrometer with a microchannel plate detector. Neutral metastable fragments are detected using a channeltron with appropriately biased meshes in front to avoid the detection of charged particles. For both types of …

    maynooth Download PDF for Development of an Apparatus for the Study of Electron Impact Fragmentation of Molecular Clusters (opens in a new tab)