Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"Refocusing Pulse"”.

  1. Human cardiac 31p magnetic resonance spectroscopy at 7 tesla

    … are overcome by designing a novel composite refocusing pulse. While scanning restrictions due to the COVID-19 pandemic meant that this sequence is not yet tested in vivo, simulations are performed to explore the potential of this sequence to measure cardiac 31P transverse relaxation times and …

    oxford Repository record for Human cardiac 31p magnetic resonance spectroscopy at 7 tesla (opens in a new tab)

  2. Towards analytical applications using SABRE-hyperpolarised benchtop NMR

    … congestion. Integrating SABRE with the multiplet-refocusing pulse sequence SHARPER led to significant signal-to-noise ratio (SNR) enhancements, as demonstrated in 19F NMR measurements on a set of fluoropyridines exhibiting diverse scalar coupling patterns. By the combined effects of SABRE and …

    whiterose Download PDF for Towards analytical applications using SABRE-hyperpolarised benchtop NMR (opens in a new tab)

  3. T2 decay curve acquisition and analysis in MRI noise considerations, short T2, and B1 field encoding

    … fluid which has a T2 ≈ 2000 ms. A multi-echo MRI pulse sequence is used to acquire a T2 decay curve which is fit using a non-negative least-squares (NNLS) curve fitting algorithm to calculate the signal as a function of the T2 (T2 distribution). The myelin water fraction (MWF) is calculated as the …

    ubc Repository record for T2 decay curve acquisition and analysis in MRI noise considerations, short T2, and B1 field encoding (opens in a new tab) Download PDF for T2 decay curve acquisition and analysis in MRI noise considerations, short T2, and B1 field encoding (opens in a new tab)

  4. Electric field sensing near the surface microstructure of an atom chip using cold Rydberg atoms

    … and and Hahn spin-echo sequences with a π refocusing pulse applied to eliminate the effects of low-frequency field noise. This decay time may be used to calculate the magnitude of the field noise if κ is known. The dc field inhomogeneity near polycrystalline metal surfaces due to patch …

    waterloo Repository record for Electric field sensing near the surface microstructure of an atom chip using cold Rydberg atoms (opens in a new tab)

  5. Simulation and Optimal Design of Nuclear Magnetic Resonance Experiments

    … developed for simulating of NMR of arbitrary pulse sequences.</p> <p>We have calculated one- and two-spin symbolically, and larger systems numerically of steady states. The one-spin calculations show how SSFP converges to continuous wave NMR. A general formula for two-spin systems has been …

    mcmaster Repository record for Simulation and Optimal Design of Nuclear Magnetic Resonance Experiments (opens in a new tab)