Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"Refrigeration compressor"”.

  1. Suction condition: Its effect on refrigeration compressor performance

    … when the refrigerant is Freon 12 and the compressor is running at a high speed. Experimental techniques were developed to measure piston leakage and fluctuating cylinder wall temperatures. The development of an electrical analogue and a rotating drum photoformer is described. This analogue …

    glasgow Download PDF for Suction condition: Its effect on refrigeration compressor performance (opens in a new tab)

  2. A novel linear electromagnetic-drive oil-free refrigeration compressor

    … acceptable operating temperatures. The linear compressor with clearance seal and flexure spring which has been used for many years for space application, is an attractive proposition for vapour compression refrigeration (VCR) systems in electronics cooling applications because it offers several …

    oxford Restricted access

  3. Acoustic prediction and noise control of a refrigeration compressor

    … of the acoustic radiation from a Bristol H25A refrigeration compressor are investigated. For the acoustic prediction, a modal decomposition approach is used. To this end, a boundary element model of the shell is created, and it is used to compute the modal radiation efficiency curves of the …

    vt Repository record for Acoustic prediction and noise control of a refrigeration compressor (opens in a new tab)

  4. Finite element modeling of a refrigeration compressor for noise prediction applications

    … finite element model of a hermetic reciprocating compressor for noise prediction applications. Inherent difficulties in developing the finite element model of a complicated structure are discussed and appropriate modeling strategies are evolved. The development of the complete compressor finite …

    vt Repository record for Finite element modeling of a refrigeration compressor for noise prediction applications (opens in a new tab)

  5. Collision Analysis of the Reversible Crankshaft Mechanism in a Convertible Refrigeration Compressor

    … of a reversible two-cylinder refrigerant compressor manufactured by Bristol Compressor Incorporated. This compressor contains a specialized linkage that causes the compressor to transition from a two-cylinder compressor to a single-cylinder compressor when the direction of rotation of the …

    vt Repository record for Collision Analysis of the Reversible Crankshaft Mechanism in a Convertible Refrigeration Compressor (opens in a new tab)

  6. Analysis of the Dynamic Interferences Between the Stator and Rotor of a Refrigeration Compressor Motor

    … finite element model of a hermetic, single-vane compressor and a single-phase alternating current induction motor assembled in a common housing. The manufacturer of this unit is experiencing a high scrap rate due to interference during operation between the stator and rotor of the motor. The …

    vt Repository record for Analysis of the Dynamic Interferences Between the Stator and Rotor of a Refrigeration Compressor Motor (opens in a new tab)

  7. Identification of sound transmission paths within a hermetic reciprocating refrigeration compressor via multiple-input/single-output modeling

    … paths of sound within a reciprocating refrigeration compressor have been investigated and ranked. By investigating the nature of sound propagation within reciprocating compressors, it is hoped that compressor manufacturers can effectively formulate strategies for compressor sound …

    vt Repository record for Identification of sound transmission paths within a hermetic reciprocating refrigeration compressor via multiple-input/single-output modeling (opens in a new tab)

  8. En kartläggning av energieffektiviseringsåtgärder för kylanläggningar ombord på fartyg

    … this demand is achieved with the help of onboard refrigeration plants. The refrigerants that are used in today’s refrigeration plants are harmful to the environment and continuous research are carried out to develop refrigerants that are less harmful. Studies show that using refrigerants that are …

    chalmers Repository record for En kartläggning av energieffektiviseringsåtgärder för kylanläggningar ombord på fartyg (opens in a new tab)

  9. Dynamic finite element modeling and analysis of a hermetic reciprocating compressor

    Dynamic finite element modeling and analysis of a refrigeration compressor was investigated as part of a noise emission study. Natural frequencies and normal mode shapes were calculated for the major structural components of the compressor. The components were later combined to form a model of the …

    vt Repository record for Dynamic finite element modeling and analysis of a hermetic reciprocating compressor (opens in a new tab)

  10. Computer aided design of twin screw compressors

    The twin screw refrigeration compressor is required to run over a large range of working conditions. In order to design an advanced and high-efficiency compressor economically, computer aided design techniques are required. This thesis presents such techniques, which include profile generation, …

    strathclyde Repository record for Computer aided design of twin screw compressors (opens in a new tab)

  11. Obtenção e caracterização de nanolubrificantes utilizados em refrigeração aditivados com nanoparticulas de Índio (In)

    … were prepared, adding 0.3 g / L to hermetic refrigeration compressor oils ISO68, ISO32, and Polyol Ester (POE). After the preparation process consisting of defragmentation and homogenization, each compound was tested in a thermostatic bath and with the aid of a rheometer and a conductivity …

    brazil-ufrn Repository record for Obtenção e caracterização de nanolubrificantes utilizados em refrigeração aditivados com nanoparticulas de Índio (In) (opens in a new tab)

  12. Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors

    Operating conditions such as load and speed of compressors are getting more aggressive to improve efficiency. Also, protection from beneficial surface layers, such as ferrous chlorides, on the critical interfaces is compromised as the refrigerants industry is moving from traditional (CFC/HFC) to …

    uiuc Repository record for Tribological studies of surface texturing for application in air-conditioning and refrigeration compressors (opens in a new tab)