Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"Reinforced Concrete Pipe"”.
-
Behavior and design of buried reinforced concrete pipe
Reinforced Concrete Pipes (RCP) are in used in the United States for almost a century. There are two methods of designing RCP, the indirect design which is an empirical method started at the beginning of the twentieth century, and the direct design method which is a more engineering oriented method …
-
The Performance of Reinforced Concrete Pipe Joints under Differential Ground Settlement
Leakage from reinforced concrete pipe joints has negative environmental impacts and can compromise the sewer or culvert’s service life. Pipes can fracture, corrode, rotate, experience joint pullout, and potentially undergo damage during their installation – leading to leakage into or out from the …
-
Cementitious Liners in Reinforced Concrete Pipes
… thesis investigates the performance of damaged reinforced concrete pipes with a focus on developing design approaches to examine the required thickness of cementitious liners to restore strength to resist earth and vehicle loads. Design seeks to prevent the development of additional cracking …
-
Application and Evaluation of Non-Destructive Testing Methods for Buried Pipes
… assessment methods for both cast iron water pipes and large diameter sewer and culvert systems. A state-of-the-art review of Non-destructive Testing (NDT) technologies available for cast iron water pipes and corrugated steel culverts identified the strengths and weaknesses of each technology. …
-
EVALUATING INFRASTRUCTURE PERFORMANCE TO ASSIST FACILITY MANAGEMENT TOWARD SUSTAINABLE SYSTEMS
… system are performed comparing three different pipe types, which are reinforced concrete pipe (RCP) and non-reinforced concrete pipe (NRCP), and vitrified clay pipe (VCP). Life cycle cost analysis is performed for material extraction, construction and rehabilitation phases. In the rehabilitation …
-
Decision-Making Guidance for Selecting Culvert Renewal Techniques
… shotcrete (RS), slip lining (SL), cured-in-place pipe (CIPP), fold and form lining (FFL), spiral-wound lining (SWL), centrifugally cast concrete pipe lining (CCCP), and pipe bursting (PB). These techniques are appropriately mapped with the commonly observed defects in reinforced concrete pipe …
-
Behaviour and Design of Reinforced Concrete Pipes
… and Direct Design methods currently used for reinforced concrete pipe are able to accurately predict the capacity of the pipe, to identify discrepancies between the two methods, and to provide potential modifications to the methods to reduce inconsistencies. As part of this investigation, two …
-
Development and Influence of Erosion Voids at Rigid Pipe Joints
… the effect that erosion voids forming at leaky reinforced concrete pipe joints have on the pipe response to surface loading. The experiment consisted of a jointed system of two 825 mm inner diameter reinforced concrete pipes, buried in a uniform sand. A section of the pipe joint was left …
-
Response of Reinforced Concrete and Corrugated Steel Pipes to Surface Load
… a single-axle frame on 600-mm-inner-diameter reinforced concrete pipe (RCP) and corrugated steel pipe (CSP) when buried in dense, well-graded sand and gravel. Measurements of the RCP at nominal and working forces and beyond are reported for 0.3, 0.6 and 0.9 m of soil cover above the pipe …
-
Performance of Trenchless Rehabilitations for Culvert, Sewer, and Maintenance Hole Structures
… voids (in the immediate backfill) on steel and reinforced concrete pipe behaviour. Additionally, the voids were rehabilitated using simple trenchless solutions and the impact on pipe capacity was explored. Furthermore, rehabilitation is also commonly performed on access structures (i.e. …
-
Simplified Design Equations and Laboratory Tests for Pipe Joints
… joint may be considered a weak point along the pipe and can have a major impact on pipe performance. However, little research has been conducted in regard to joint design. To improve current structural design criteria, this thesis presents the findings and conclusions of experimental and …
-
Behaviour of Deteriorated Pipes Rehabilitated With Grouted Slipliners
… the performance of both deteriorated steel and reinforced concrete culverts rehabilitated with grouted slipliners subjected to surface loading. Bench scale experiments were conducted to evaluate the use of fibre optic sensors against conventional strain sensors. Then, fibre optic sensors were …
-
Experimental Study on the Longitudinal Strain Behavior of Polymer Pipe Liners Crossing Joints in Reinforced Concrete Pipes under Surface Loading
… water and wastewater infrastructure consists of reinforced concrete pipes (RCPs) with bell-and-spigot joints. As these pipelines age, trenchless rehabilitation methods such as Cured-in-Place Pipe (CIPP) and Spray-in-Place Pipe (SIPP) liners are increasingly adopted as cost-effective and minimally …