Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"Reinforced Masonry Wall"”

  1. Development of composite auxetic structures for civil engineering applications

    … The developed auxetic structures can be reinforced into either for existing structural elements or for newly built one. Novel macro auxetic structures were developed from core fibre reinforced braided composite rods based on missing rib or lozenge grid and re-entrant hexagon or bow-tie …

    minho-thes Repository record for Development of composite auxetic structures for civil engineering applications (opens in a new tab)

  2. Displacement-based seismic design and tools for reinforced masonry shear-wall structures

    … Seismic Design Methods and Tools for Reinforced Masonry Shear-Wall Structures.” Within the context of that project, the objective of the research described in this dissertation was to develop and validate a specific displacement-based seismic design methodology for masonry structures. …

    texas Repository record for Displacement-based seismic design and tools for reinforced masonry shear-wall structures (opens in a new tab)

  3. Sliding displacements in reinforced masonry walls subjected to in-plane lateral loads

    Seismic design provisions in the Canadian Masonry Code often lead to indications that the governing yield mechanism for a reinforced masonry wall with a height/length (H/L) ratio below 1.0 and under low axial loads will not achieve the design objective of a flexural yield mechanism and instead, …

    ubc Repository record for Sliding displacements in reinforced masonry walls subjected to in-plane lateral loads (opens in a new tab)

  4. Design Considerations for Reinforced Concrete Masonry Walls Regarding Moment Magnification

    <p>Currently, regardless of the height of a reinforced masonry wall, engineers are required to consider moment magnification when using strength design provisions. An attempt at finding reasonable <em>h/r</em> limits for consideration of moment magnification is explored. Moment-curvature diagrams …

    ut-knoxville Repository record for Design Considerations for Reinforced Concrete Masonry Walls Regarding Moment Magnification (opens in a new tab)

  5. Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls

    … reports on shake table tests on fully-grouted reinforced masonry (RM) shear walls. The test walls covers a range of design parameters to facilitate benchmarking, a thorough performance investigation, and calibration of numerical models as well as development of fragility curves within the …

    mcmaster Repository record for Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls (opens in a new tab)

  6. Strengthening of reinforced masonry walls subjected to out-of-plane pseudo-static cyclic load using advanced composite

    … have conducted experimental tests on unreinforced masonry walls (URM) strengthened with advanced composite materials. Consequently, the strengthening design guidelines are limited in their scope to URM. This research aimed to investigate the behavior of reinforced masonry walls …

    must-thes Repository record for Strengthening of reinforced masonry walls subjected to out-of-plane pseudo-static cyclic load using advanced composite (opens in a new tab)

  7. Performance of Protective Perimeter Walls Subjected to Explosions in Reducing the Blast Resultants on Buildings

    … blast effects on structures located behind blast walls are based on plane rigid walls and the results of small-scale studies, which are not validated by the results of full-scale experiments. Hence, they are only valid for a very limited range of scaled parameters. Also, they do not account for …

    uwo Repository record for Performance of Protective Perimeter Walls Subjected to Explosions in Reducing the Blast Resultants on Buildings (opens in a new tab)

  8. Nonlinear Least-Squares Prediction of Effective Flexural Stiffness in Slender Reinforced Masonry Walls

    Slender reinforced concrete block masonry walls with effective height-to-thickness (h⁄t) ratios greater than 30 are commonly used as loadbearing elements in single-storey commercial and industrial buildings, including warehouses, schools, gymnasiums, and similar structures. Load-bearing walls are …

    alberta Repository record for Nonlinear Least-Squares Prediction of Effective Flexural Stiffness in Slender Reinforced Masonry Walls (opens in a new tab)

  9. Seismic Performance of Ductile Reinforced Concrete Masonry Shear Walls with C-Shaped Boundary Elements

    … cost and minimum environmental impact. Although reinforced masonry construction is known for its better fire protection, structural durability, energy efficiency and cost reduction, its use is hindered by the lack of knowledge of its resistance to earthquake loads. The main objective of this …

    concordia

  10. Development of Innovative in-Line Stiffening Element for Out-of-Plane Masonry Walls

    Tall, slender masonry walls are a competitive solution for resisting both out-of-plane (OOP) and gravity loads in low and high-rise structures. The use of taller and thinner walls is appealing due to the use of less material, need for smaller foundations, faster construction, lower seismic forces, …

    alberta Repository record for Development of Innovative in-Line Stiffening Element for Out-of-Plane Masonry Walls (opens in a new tab)

  11. Computational framework for the analysis of hybrid masonry systems using an improved non-local technique

    Hybrid masonry structures combine the ductility of steel components with the shear strength of reinforced masonry panels. The goal of this research is to provide a sound basis for the design of an optimal type of hybrid structure that can be implemented as a new lateral-force-resisting system in …

    rice Repository record for Computational framework for the analysis of hybrid masonry systems using an improved non-local technique (opens in a new tab)