Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 194 for “"Reinforcement ratio"”.

  1. Evaluating and Relaxing the Limits on Flexural Reinforcement Ratio of Masonry Shear Walls

    … are constrained by TMS 402/602 code limits on reinforcement ratios ("ρ" _"max" ) and axial compressive stresses (≤10% of masonry compressive strength, f_m^'), undermining masonry’s inherent compression capacity under high axial loads. This dissertation investigates the seismic performance of …

    must-thes Repository record for Evaluating and Relaxing the Limits on Flexural Reinforcement Ratio of Masonry Shear Walls (opens in a new tab)

  2. Effects of Loading Age and Transverse Reinforcement Ratio on Collapse Resistance of RC Frame Beams under High Sustained Loads

    … (between 50 and 267 days) and beam transverse reinforcement ratio (0.327%, 0.436%, and 0.655%). The specimens were tested at high sustained loads of 80% and 90% of the nominal short-term loading capacity under compressive arch action. The performance of a specimen tested in an earlier study was …

    unlv Repository record for Effects of Loading Age and Transverse Reinforcement Ratio on Collapse Resistance of RC Frame Beams under High Sustained Loads (opens in a new tab) Download PDF for Effects of Loading Age and Transverse Reinforcement Ratio on Collapse Resistance of RC Frame Beams under High Sustained Loads (opens in a new tab)

  3. Evaluation of the effects of in-plane lateral restraint and reinforcement ratio on the punching capacity of flat slab column specimens

    … of the slabs prior to failure and the effects of reinforcement ratio before and after the failure occurs. Better estimation of the punching shear capacity will lead to better prediction if the punching shear failure will cause a progressive collapse. Isolated slab column specimens were constructed …

    missouri Repository record for Evaluation of the effects of in-plane lateral restraint and reinforcement ratio on the punching capacity of flat slab column specimens (opens in a new tab)

  4. Average reinforcement strain in reinforced concrete structures loaded until failure - An experimental study on the effect of reduced interaction and reinforcement ratio on plastic deformation capacity

    … a revision is needed, average tensile strain of reinforcement at failure is an effective factor representing plastic deformation capacity. The aim of this project was to study the effect of reinforcement amount and decreased interaction between steel and concrete on reinforcement average strain …

    chalmers Repository record for Average reinforcement strain in reinforced concrete structures loaded until failure - An experimental study on the effect of reduced interaction and reinforcement ratio on plastic deformation capacity (opens in a new tab)

  5. Seismic performance of circular GFRP-RC bridge columns under simulated seismic loading including torsion

    … column heights. Fibre-reinforced polymer (FRP) reinforcement offers a durable alternative to traditional steel bars in aggressive environments, given its corrosion resistance. Recent research has focused on the seismic behaviour of FRP-RC columns. Yet, existing seismic provisions for FRP-RC …

    manitoba Repository record for Seismic performance of circular GFRP-RC bridge columns under simulated seismic loading including torsion (opens in a new tab)

  6. Strength and ductility of high-strength concrete shear walls under reversed cyclic loading

    … test parameters investigated being longitudinal reinforcement ratio, transverse reinforcement ratio and axial load. Lateral loads, lateral displacements and the strains of reinforcement in edge elements and web wall were measured. The test results showed the presence of axial load has a …

    unsw Repository record for Strength and ductility of high-strength concrete shear walls under reversed cyclic loading (opens in a new tab)

  7. FRP shear strengthening of concrete beams

    … where concrete beams are subjected to deterioration mainly instigated by heavier traffic loads, poor initial design, aggressive exposure conditions, natural or man-made extreme events, and steel reinforcement corrosion. All these circumstances may lead to catastrophic consequences unless …

    birmingham Download PDF for FRP shear strengthening of concrete beams (opens in a new tab)

  8. Numerical investigation of the effectiveness of FRP and TRM in repairing corrosion damaged reinforced concrete beams

    … concrete (RC) structures, corrosion reduces the reinforcement cross-sectional area and causes cracking and/or spalling of the concrete cover. This will reduce the strength of the structure and may cause collapse. A certain degree of structural strength can be preserved and/or increased by using …

    ubc Repository record for Numerical investigation of the effectiveness of FRP and TRM in repairing corrosion damaged reinforced concrete beams (opens in a new tab) Download PDF for Numerical investigation of the effectiveness of FRP and TRM in repairing corrosion damaged reinforced concrete beams (opens in a new tab)

  9. Strengthening Slender S-Section Steel Columns Using CFRP Plates of Various Moduli

    … weak axis. Twelve columns, with a slenderness ratio of 197, were tested, of which nine were strengthened with CFRP. The main parameters tested were the level of initial out-of-straightness (length (L)/8387 to L/1020), CFRP modulus (168 to 430 GPa), CFRP reinforcement ratio (13% to 34%) and the …

    queens Repository record for Strengthening Slender S-Section Steel Columns Using CFRP Plates of Various Moduli (opens in a new tab)

  10. Punching shear behaviour of FRP-reinforced concrete interior slab-column connections

    … the corrosion problems associated with steel reinforcement. However, the available literature shows few studies to evaluate the behaviour of FRP-RC interior slab-column connections tested mainly under concentric loads, which seldom occurs in a real building. The main objectives of this …

    manitoba Repository record for Punching shear behaviour of FRP-reinforced concrete interior slab-column connections (opens in a new tab)

  11. Behaviour of concrete corbels reinforced with GFRP bent bars

    … and the remaining two were reinforced with steel reinforcement as control specimens. Four out of the twelve GFRP-RC corbels were cast using high-strength concrete (HSC), while the remaining eight were constructed using normal-strength concrete (NSC). The corbel was tapered with cross-sectional …

    manitoba Repository record for Behaviour of concrete corbels reinforced with GFRP bent bars (opens in a new tab)

  12. Tests on GFRP Reinforced Concrete Knee-Joints Subjected to Negative Moments

    … use of glass-fibre reinforced polymers as main reinforcement in concrete structures has become an appealing option for structures in aggressive environments. Concrete knee-joints are joints where the beam and column both terminate at the joint. The application GFRP reinforcement in knee-joints …

    waterloo Repository record for Tests on GFRP Reinforced Concrete Knee-Joints Subjected to Negative Moments (opens in a new tab)

  13. Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement

    … Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs and corrugated bars) when normal strength concrete (NSC) is used. All specimens were tested under concentric shear force and …

    manitoba Repository record for Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement (opens in a new tab)

  14. Strength and Serviceability of Concrete Elements Reinforced with High-Strength Steel

    The potential use of high-strength steel reinforcement (HSSR) with yield stress (𝑓𝑦) larger than 80 ksi requires reconsideration of design criteria and limits used to avoid sudden failure because they were conceived for elements with Gr. 60 and 80 (𝑓𝑦=60 and 80 ksi) reinforcement. The objective of …

    purdue-thes Repository record for Strength and Serviceability of Concrete Elements Reinforced with High-Strength Steel (opens in a new tab)

  15. Punching shear behaviour of GFRP-RC slab-column edge connections with high strength concrete and shear reinforcement

    … connections investigating the effect of flexural reinforcement ratio (0.90, 1.35 and 1.80%) when high strength concrete (HSC) is used, while Series II included four connections investigating the effect of GFRP shear reinforcement type and pattern on normal strength concrete (NSC) connections. Test …

    manitoba Repository record for Punching shear behaviour of GFRP-RC slab-column edge connections with high strength concrete and shear reinforcement (opens in a new tab)

  16. Behaviour of Concrete Sandwich Wall Panels in Flexure Using a Novel GFRP Shear Connector

    … four-point bending, varying the connector configuration and type as well as the wythe reinforcement ratio. The connectors investigated were a continuous GFRP channel, a discrete GFRP channel consisting of multiple segments spaced apart and a control conventional steel truss. Ancillary push-off …

    queens Repository record for Behaviour of Concrete Sandwich Wall Panels in Flexure Using a Novel GFRP Shear Connector (opens in a new tab)

  17. Reliability-based durability assessment of GFRP bars for reinforced concrete

    … concrete strength, fractions of balanced reinforcement ratio, reinforcing bar tensile strength, and environmental reduction factors on the flexural capacity of GFRP reinforced concrete beams. Reliability analysis was successfully used to determine an environmental reduction factor of 0.5 …

    vt Repository record for Reliability-based durability assessment of GFRP bars for reinforced concrete (opens in a new tab)

  18. Shear behaviour of corroded reinforced concrete t-beams repaired with fibre reinforced polymer systems

    … effect of concrete strength, steel-to-CFRP shear reinforcement ratio and shear span-to-effective depth ratio was carried out. The FE predictions suggest that the embedded CFRP shear contribution decreases with the increase in steel-to-CFRP shear reinforcement ratio and shear span-to-effective …

    birmingham Download PDF for Shear behaviour of corroded reinforced concrete t-beams repaired with fibre reinforced polymer systems (opens in a new tab)

  19. Behavior of Aged Reinforced Concrete Columns Under High Sustained Concentric and Eccentric Loads

    … loading, (2) examine the effects of transverse reinforcement ratio on the creep behavior of RC columns, (3) examine and explore a numerical method based on an existing nonlinear creep model for aged concentrically loaded concrete columns under high sustained stresses. To achieve the research …

    unlv Repository record for Behavior of Aged Reinforced Concrete Columns Under High Sustained Concentric and Eccentric Loads (opens in a new tab) Download PDF for Behavior of Aged Reinforced Concrete Columns Under High Sustained Concentric and Eccentric Loads (opens in a new tab)

  20. Service load cracking behavior of reinforced concrete bridge decks

    … to use PCPs on steel girder systems, the deck reinforcement and cracking behavior in the negative moment regions of continuous girder systems is of interest. However, there is currently inadequate guidance on reinforcing requirements for the cast-in-place portion of bridge decks constructed …

    texas Repository record for Service load cracking behavior of reinforced concrete bridge decks (opens in a new tab)

Page 1 of 10