Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 152 for “"Relative Errors"”
-
Rawinsonde errors and their application to a mesoscale study
Several studies of rawinsonde component errors in actual flight tests are discussed. RMS relative errors between radiosondes are assumed for measured parameters. These errors are then used to derive RMS relative errors for other parameters such as wind speed and direction, height, virtual …
-
TWO ESSAYS ON QUANTITATIVE FINANCE: RISK ANALYSIS AND CORPORATE RISK MANAGEMENT
… being computed using asymptotic expansions of relative errors for a wide class of dependent samples. An extensive numerical study is conducted to compare the proposed algorithm against existing algorithms, showing that the new algorithm is easy to implement, fast and accurate, even at the 0.001 …
-
ΚΑΤΑΣΚΕΥΗ ΕΝΟΣ ΝΕΟΥ ΑΝΑΛΥΤΟΥ ΕΓΧΥΣΗΣ ΣΕ ΡΟΗ (F.I.A) ΚΑΙ ΧΡΗΣΗ ΑΜΠΕΡΟΜΕΤΡΙΚΩΝ ΒΙΟΑΙΣΘΗΤΗΡΩΝ:ΜΕΛΕΤΗ ΚΑΙ ΝΕΕΣ ΕΦΑΡΜΟΓΕΣ ΕΝΖΥΜΙΚΩΝ ΑΝΤΙΔΡΑΣΕΩΝ
… BY COMPARISON WITH A REFERENCE METHOD. THE MEAN RELATIVE ERRORS WERE 2,2%, 3,0% AND 2,4% RESPECTIVELY.
-
Modeling and Simulation of Novel Bioplastic Materials Reinforced with Cellulose Nanocrystals
… but with some limitations. These models obtained relative errors up to 11.70%. On the other hand, the proposed model for the purely isotropic samples did not capture the nonlinearity of the data resulting in relative errors of up to 21.83%. Lastly, we provide a discussion on the obtained results …
-
Application of Data-Driven and Process-Based Modeling Approaches for Water Quality Simulation in Lakes and Freshwater Reservoirs
… depths from May 2018 to April 2019, with mean relative errors of less than 6.1% and 4.2%, respectively. The model was also used to evaluate the mixing intensities at different depths during the study period. The second approach employed two separate data-driven models incorporating wavelet …
-
Analytical and Other Applications of Some Quaternary Ammonium Compounds
… of chlorate are presented. With careful work, relative errors of ± 0.2% can be expected in the range of 50-100 mg of perchlorate, ± 1.0% in the 10-50 mg range, and ± 5.0% in the range from 2-10 mg of perchlorate. A method is described for the separation and determination of Ta in the presence …
-
Analysis of form errors in rings of non-uniform cross section due to workholding and machining loads
… with experimental observations, with average relative errors of 11.6 and 7.2 percent, respectively.
-
Advanced Flame Monitoring and Emission Prediction through Digital Imaging and Spectrometry
… Network using the above inputs has produced relative errors of around 3%, and maximum relative errors of 8% under real industrial conditions, even when predicting flame data from test conditions not disclosed to the network during the training procedure. This demonstrates that this off the …
-
Development of a Heat Recovery System for a 250 kW Fluidized Bed Gasification System Fueled by Cotton Gin Trash
… estimated to be 0.03 W m⁻¹ K ⁻¹, which reduced relative errors of heat capture modeling to below 10%. A large-scale heat exchanger was evaluated for correcting a heat transfer model, where relative errors of heat capture were also reduced to below 10%. An HRS model was developed to predict …
-
Continuous Phase Synchronised Drives (for a rod-making machine)
… at continuous high speed (2500 r/min), with low relative phase errors between two drives (0.0025 radians). Traditional minimum energy drive selection techniques for incremental motions were not applicable to continuous applications which require negligible energy dissipation. New selection …
-
Monetary Unit Acceptance Sampling: Sequential and Fixed Sample Size Plans for Substantive Tests in Auditing
… against a binomial error distribution (i.e. relative errors in the population are 0% or 100% only). For typical error distributions, the test is generally conservative in that actual risks are bounded by nominal risks. Both sequential and fixed sample size plans are developed, and, for these …
-
The `Electric' Pascal: Absolute and Dynamic Calibration Techniques
… pressures in the range of 0.1 to 600 Pa with relative errors of 1.5%.
-
Measurements of Air Flow Velocities in Microchannels Using Particle Image Velocimetry
… to the PIV results for validation purposes, with relative errors between CFD and PIV typically between 2% and 10%. The agreement between the experimental data and computational results ranged from acceptable to excellent, validating this method. The channel with lowest aspect ratio consistently …
-
Nondestructive evaluation of out-of-plane wrinkles within woven carbon fiber reinforced plastics (CFRP) using ultrasonic detection.
… as they provide a great strength to weight ratio relative to their metallic counterparts. A drawback is they require complex manufacturing processes, and the final part performance is sensitive to internal defects. Of focus in the present study are out-of-plane wrinkles, specifically those not …
-
Characterization of sub-surface wrinkles within a laminated composite using a novel phased array ultrasonic scanning technique incorporating a portable nozzle and robotic arm.
… and results are provided that show average relative errors of 8.33%, 22.79% and 9.72% for, respectively, wrinkle height, width, and intensity corresponding to an average absolute error of, respectively, 0.057mm, 1.59mm and 4.7 × 10−3 .
-
Test Methodology for Residential Stationary Battery Energy Storage Systems
… selection of the representative days assess the relative error between sums and averages values of the annual and representative day system profiles. These representative days serve as the basis for the compressed test sequence. To evaluate the performance of the system, the relevant performance …
-
Correlated Sample Synopsis on Big Data
… (or SRSWOR) return results with extremely high relative errors for join queries. Existing methods, such as Join Synopses, only work well with foreign key joins, and the sample size can grow dramatically as the dataset gets larger. This research aims to provide that CS2 can speed up search query …
-
Commissioning and Sensitivity Studies for the SuperNEMO Demonstrator Module
… simulated data. Results of the sensitivity and relative errors of two key back- grounds, 208Tl and 214Bi, for the demonstrator module will be presented here. The enhancement of the gas system and integra- tion with slow control will also be presented.
-
Parameters Estimation for Stochastic Genetic Evolution of Asexual Populations
… to evaluate the estimation quality. The fitting errors were of the order of 10^(-2). Depending on the number of runs per simulated experiment, ranging between 10^2 and 10^5, the successful prediction of the number of possible mutants was within 78% and 99.4%, respectively. Their selective …
-
Computing optimal cocomo effort multiplier values and optimal casebase subsets using monte carlo methods
… the average of the absolute values of the relative errors (AARE) of man-month estimate for two industry supplied casebases. For example, when using three COCOMO cost drivers (complexity, language experience, application experience) and the COCOMO effort multiplier values, AARE values were …
Page 1 of 8