Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"Relative dosimetry"”.

  1. ABSOLUTE AND RELATIVE DOSIMETRY FOR THE ELIMED BEAM LINE

    … with the main purpose to realize a transport and dosimetry beam line, named ELIMED (ELI- Beamlines MEDical and multidisciplinary applications), for laser accelerated ions. In this thesis, dosimetry of laser-driven proton beams is discussed and results obtained with the dosimetric detectors …

    catania Repository record for ABSOLUTE AND RELATIVE DOSIMETRY FOR THE ELIMED BEAM LINE (opens in a new tab)

  2. Small field dosimetry: experimental methods and Monte Carlo simulation in small field radiation therapy dosimetry

    … the requirements are for accurate small field relative dosimetry. Diode detector selection and experimental techniques were evaluated. EGSnrc Monte Carlo simulations were used to predict diode detector dosimetric parameters and assist in interpreting measured data. An emerging scintillator …

    whiterose Download PDF for Small field dosimetry: experimental methods and Monte Carlo simulation in small field radiation therapy dosimetry (opens in a new tab)

  3. Characterization of a micro-ionization chamber for electron FLASH dosimetry

    … normal tissue toxicity, have created a need for dosimetry tools that can accurately quantify doses delivered at these extreme rates. However, dosimetry in UHDR environments presents specific challenges, as the rapid delivery can influence detector response, leading to significant errors in dose …

    ubc Repository record for Characterization of a micro-ionization chamber for electron FLASH dosimetry (opens in a new tab) Download PDF for Characterization of a micro-ionization chamber for electron FLASH dosimetry (opens in a new tab)

  4. Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων

    … and depth dependent differences, beyond film dosimetry uncertainty (<3.3), from corresponding MC simulations (up to 8%). The observed differences reduced only slightly when spectral variation as a function of depth was accounted for. Experimental data along with additional MC simulations in …

    greece Repository record for Εφαρμογή τρισδιάστατης χημικής δοσιμετρίας στην ακτινοθεραπεία δερματικών νόσων (opens in a new tab)

  5. Development of an Independent Monte Carlo Dose Calculation Tool for Validation of the Monaco Electron Treatment Planning System

    … factors are required to correct for absolute dosimetry predictions. If sufficient effort and refinements are made, in-house MC models can produce superior relative dosimetry results compared to commercial TPSs due the greater control over the end-to-end dose prediction process with the …

    adelaide Repository record for Development of an Independent Monte Carlo Dose Calculation Tool for Validation of the Monaco Electron Treatment Planning System (opens in a new tab)

  6. Ανάπτυξη Monte Carlo προσομοιώσεων και δοσιμετρικών υπολογισμών σε σύγχρονα συστήματα γραμμικών επιταχυντών με ενσωματωμένο μαγνητικό τομογράφο (MR-Linacs)

    … increasing the challenges in experimental dosimetry procedures. In addition, the absence of a dosimetry protocol or code-of-practice that accounts for the impact of the magnetic field exacerbates these challenges. Thus, this thesis aims to contribute to the existing data on MR-Linac …

    greece Repository record for Ανάπτυξη Monte Carlo προσομοιώσεων και δοσιμετρικών υπολογισμών σε σύγχρονα συστήματα γραμμικών επιταχυντών με ενσωματωμένο μαγνητικό τομογράφο (MR-Linacs) (opens in a new tab)

  7. Studio e sviluppo di un nuovo sistema diagnostico basato sulla tecnologia SiC per la dosimetria relativa e la determinazione del range di protoni

    I principali vantaggi della terapia con protoni rispetto alla terapia con fotoni sono le capacità balistiche superiori e il range limitato del fascio. Tuttavia, nella pratica clinica, la valutazione del range nel tessuto è affetta da incertezze associate alle procedure di imaging, di …

    catania Repository record for Studio e sviluppo di un nuovo sistema diagnostico basato sulla tecnologia SiC per la dosimetria relativa e la determinazione del range di protoni (opens in a new tab)