Improving relative stopping power calibration in X-ray treatment planning CT using sparse proton radiographies
… irradiated tissue to stop ions, i.e., the tissue stopping power, needs to be determined to a high degree of accuracy. Currently, treatment planning is based on an X-ray computed tomography (CT) of the patient acquired prior to treatment, which is converted to stopping power relative to water based …
-
Robust and efficient methods for proton computed tomography.
… with the goal of generating accurate 3D maps of relative stopping power (RSP) with respect to water. Since the early developments of this imaging technique in 1970's, there have been significant improvements regarding the reconstruction of accurate RSP which makes pCT a reliable alternative to …
-
Implementation of An Anthropomorphic Phantom For The Evaluation of Proton Therapy Treatment Procedures
… was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each …
-
Chord length methods for proton computed tomography.
… from pCT scans provide information about the Relative Stopping Power of the object scanned. Proton and ion therapies can administer radiation with higher conformity than traditional photon therapies. The RSP values provided by pCT scans are particularly useful when planning proton and ion …
-
A Comparative Analysis of Water-Equivalent Path Length of Tissue Samples using a Fast Monolithic Proton Radiography System
… conversion to translate Hounsfield Units (HU) to relative stopping power (RSP). This conversion can be inaccurate by up to 4%, and is currently the greatest cause of uncertainty in proton therapy. While there exist several ways around this, directly measuring RSP with proton imaging is the most …
-
The Development and Implementation of An Anthropomorphic Head Phantom For The Assessment of Proton Therapy Treatment Procedures
… ±5%/3mm with a reproducibility of ±3%. The relative stopping power (RSP) and Hounsfield Units (HU) were measured for potential phantom materials and a human skull was cast in tissue-equivalent Alderson material (RLSP 1.00, HU 16) with anatomical airways and a cylindrical hole for imaging and …
-
Particle imaging for daily in-room image guidance in particle therapy
… planning x-ray CT to the patient specific relative stopping power (RSP) map that is crucial for accurate treatment planning. By measuring the energy loss of particles after traversing the patient, particle imaging enables a more direct reconstruction of the RSP. In this thesis, different …
-
Development and Implementation of An Anthropomorphic Pediatric Spine Phantom For The Assessment of Craniospinal Irradiation Procedures In Proton Therapy
… equivalency was determined by measuring the relative stopping power and Hounsfield unit of potential phantom materials. The materials selected as bone, tissue, and cartilage substitutes were Techron HPV Bearing Grade (RSP 1.3, HU 595.6), solid water (RSP 1.004, HU 16), and blue water (RSP …
-
A Method for Online Dose Prediction for Image Guided Proton Therapy
… CT (QACT), the standard hounsfield unit (HU) to relative stopping power (RSP) curve used in the treatment planning system (TPS), as well as a simple gaussian smoothing to lessen the local effects of CBCT artifacts. The comparison itself involved interpolating each line dose along the beam path …
-
Applications of particle physics techniques for proton computed tomography
… The results show excellent image contrast and relative stopping power reconstruction.
-
Proton computed tomography
L'utilisation de protons dans le traitement du cancer est largement reconnue grâce au parcours fini des protons dans la matière. Pour la planification du traitement par protons, l'incertitude dans la détermination de la longueur du parcours des protons provient principalement de l'inexactitude dans …