Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 23 for “"Removal Torque"”.
-
Effect of capper head rotation speed on immediate removal torque
Thesis (M.S.)--Michigan State University. School of Packaging, 1999
-
Model for predicting application torque and removal torque of a continuous thread closure
Thesis (M.S.)--Michigan State University. Department of Packaging, 2000
-
The Effect of Induction Sealing and Time on Removal Torque of Continuous-Thread and Child Resistant Plastic Closures
… of an induction sealing process and time on the removal torque of continuous thread and child resistant plastic closures. An application torque of 19 in-lb was applied to the high density polyethylene (HDPE) bottle/closure systems. After passing the bottle/closures through the induction sealer, …
-
The effects of capper rotational speed and magnetic clutch type on the immediate removal torque of CT closures
Thesis (M.S.)--Michigan State University. Department of Packaging, 2001
-
Measuring and modeling the effect of time and temperature on removal torque and sealing force of a continuous thread closure
Thesis (Ph. D.)--Michigan State University, School of Packaging, 2002
-
Influence of abutment material and implant diameter on implant deformation, abutment removal torque loss and static loading strength in conical connection implant-abutment assemblies after simulated long-term oral use
This is the pre-peer reviewed version of the following article: [Zhai, Z, Nakano, T, Chen, Y, Watanabe, S, Matsuoka, T, Ishigaki, S. Implant deformation and implant–abutment fracture resistance after standardized artificial aging: An in vitro study. Clin Implant Dent Relat Res. 2023; 25( 1): 107- …
-
Comparative Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study
… Evaluation of Bending Resistance and Retentive Torque Stability of Zest Locator® and Straumann Novaloc® Abutments: An In Vitro Study Hammad Ul Haq B.D.S. Objective: To compare the mechanical performance of Locator® (Zest Anchors) and Novaloc® (Straumann) implant overdenture attachment systems …
-
Η επίδραση του β-αδρενεργικού ανταγωνιστού στην οστική ενσωμάτωση των ορθοπαιδικών εμφυτευμάτων από ανοξείδωτο χάλυβα: πειραματική μελέτη σε επίμυες
… harvested and the implants’ pullout-strength and removal torque were assessed. Results. All animals completed the study and all harvested tibias were suitable for evaluation. Both parameters were different between the two groups, favoring the study group, albeit in a non-statistically significant …
-
Stability and Three-Dimensional Analysis of Bone Formation in Longitudinally Fluted Miniscrew Implants
… with 100g using NiTi coil springs. Insertion torque values were obtained for each MSI that was placed; removal torque values were obtained for 28 MSIs that had been in place for 6 weeks and 20 MSIs that had been in place for 2 weeks. The bone volume fraction surrounding the implant 6-to-24 μm, …
-
Vergleich unterschiedlicher Methoden der Implantatbettpräparation und ihr Einfluss auf die Osseointegration eines Standardzahnimplantates
… der Implantate wurde für den biomechanischen Removal Torque Test, die Andere für die Histologie verwendet. Grundsätzlich konnte für alle Implantate eine sehr gute Osseointegration nachgewiesen werden, wobei die histologische Auswertung Unterschiede zwischen den einzelnen Gruppen zu den drei …
-
Use of Anaerobic Adhesive for Prevailing Torque Locking Feature on Threaded Product
… anaerobic adhesive can be used as a prevailing torque locking feature. Maintaining preload in critical joints is the usual standard that anaerobic adhesives are held to in aerospace and other industry. To test if anaerobic adhesive can be used as a prevailing torque locking feature a test …
-
Einfluss von unterschiedlichen Implantatmakrodesigns und Oberflächenmodifikationen auf das osseointegrative Verhalten von sechs verschiedenen Titan-Implantattypen: eine histologische und biomechanische Analyse im Schafmodell
… Die restlichen 72 Implantate wurden einem Removal-Torque-Test unterzogen. Die Schlachtung der Tiere erfolgte nach zwei und acht Wochen. Im Removal-Torque-Test ergaben sich signifikante Unterschiede (p≤0,001) zwischen den Makrodesigns (gesintert porös und beschichtet maschiniert) nach acht …
-
Biomechanical and histological evaluation of a new zirconia implant in a canine model
… the bone-implant contact (BIC), bone area (BA), removal torque (RTQ), mineral apposition rate (MAR), bone forming area (BFA), and Periotest value (PTV) of the two groups were studied and compared. Results: At 12 weeks post operatively, one Shofu thread type Ti implant were not integrated. Over …
-
Der Einfluss von Implantatgeometrie und Implantatoberfläche auf den Implantat-Knochen-Verbund : eine vergleichende Analyse im Schafsmodell
… wurden die messbaren Eindrehkräfte (Torque-in) sowie die Resonanzfrequenz (ISQ) gemessen um einen Hinweis auf die Primärstabilität zu erhalten. Die ISQ-Messung wurde nach der Schlachtung wiederholt und anschließend die Proben einem biomechanischen Ausdrehtest (Removal Torque) …
-
Vergleich von zwei modifizierten dentalen Titanoberflächen mit gleichem Makrodesign im Hinblick auf ihre osseointegrativen Eigenschaften : eine histologische und biomechanische Analyse im Schafmodell
… sowie eine biomechanische Analyse mittels Removal Torque Test (n=6) durchgeführt. Der implant-stability-quotient (ISQ) wurde bei A und B nach 0, 2, 4 und 8 Wochen anhand der Resonanzfrequenzanalyse (RFA) ermittelt. Beide Implantattypen bewiesen ausgezeichnete Eigenschaften hinsichtlich …
-
Effect of HA-coating and HF etching on experemental zirconia implant evaluation using in vivo rabbit model
… kept in 0.9% saline and were evaluated using removal torque (RT) analysis to assess the strength of the implant-to-bone interface. The histomorphometric examination demonstrated direct bone-to-implant contact for all four groups. HA particle separation from the implants surface was seen in a …
-
Η επίδραση της χορήγησης α-τοκοφερόλης στην οστική ενσωμάτωση των ορθοπαιδικών εμφυτευμάτων από ανοξείδωτο χάλυβα και στο οξειδωτικό stress
… rats as determined by (1) pull-out strength and removal torque and (2) a histomorphological assessment of bone formation. In addition, we investigated, (3) the correlation between the administration of alpha-tocopherol and the reduction in postoperative oxidative stress that develops after …
-
Torque Performance and Material Characterization of Post-Consumer Recycled Polypropylene Caps: A Comparative Study of Virgin, 40% PCR, and 100% PCR Closures on 100% PCR HDPE Detergent Bottles
… recycled (PCR) content on the application and removal torque of 28/400 continuous-thread polypropylene caps tested against 100% PCR high-density polyethylene (HDPE) detergent bottles. Three cap material variables were evaluated: virgin PP (0% PCR), 40% PCR PP, and 100% PCR PP. Torque testing …
-
Histomorphometric and Biomechanical Analyses of Osseointegration of Four Different Orthodontic Mini Implant Surfaces
… Zealand white rabbits. Biomechanical properties (Removal torque and hardness) measurements and histomorphometric observations were measured. Results: Ra and Rq of groups were: Machined (1.17±0.11, 2.59±0.09) Acid etched (1.82±0.04, 3.17±0.13), Grit blasted (4.83±0.23, 7.04±0.08), Grit blasted + …
-
Novel ultra-thin hydroxyapatite coatings on medical implants used as local drug delivery system – in-vitro and in-vivo characterization
… the HA coating in-vivo. Overall, the insertion torques (during implantation) of the HA coated screws were comparable to uncoated, commercially available screws. After two weeks, increased early implant stabilization was demonstrated by significantly higher removal torques for HA coated screws. …
Page 1 of 2