  1. The Effect of Induction Sealing and Time on Removal Torque of Continuous-Thread and Child Resistant Plastic Closures

    … of an induction sealing process and time on the removal torque of continuous thread and child resistant plastic closures. An application torque of 19 in-lb was applied to the high density polyethylene (HDPE) bottle/closure systems. After passing the bottle/closures through the induction sealer, …

    rit Repository record for The Effect of Induction Sealing and Time on Removal Torque of Continuous-Thread and Child Resistant Plastic Closures (opens in a new tab)

  2. Histomorphometric and Biomechanical Analyses of Osseointegration of Four Different Orthodontic Mini Implant Surfaces

    … Zealand white rabbits. Biomechanical properties (Removal torque and hardness) measurements and histomorphometric observations were measured. Results: Ra and Rq of groups were: Machined (1.17±0.11, 2.59±0.09) Acid etched (1.82±0.04, 3.17±0.13), Grit blasted (4.83±0.23, 7.04±0.08), Grit blasted + …

    iupui Repository record for Histomorphometric and Biomechanical Analyses of Osseointegration of Four Different Orthodontic Mini Implant Surfaces (opens in a new tab)

  3. Novel ultra-thin hydroxyapatite coatings on medical implants used as local drug delivery system – in-vitro and in-vivo characterization

    … the HA coating in-vivo. Overall, the insertion torques (during implantation) of the HA coated screws were comparable to uncoated, commercially available screws. After two weeks, increased early implant stabilization was demonstrated by significantly higher removal torques for HA coated screws. …

    cau-kiel Repository record for Novel ultra-thin hydroxyapatite coatings on medical implants used as local drug delivery system – in-vitro and in-vivo characterization (opens in a new tab)

  4. The elaboration of a novel TAD design and its comparison to an industrial design

    … using the Instron 5566A to measure the insertion torques and removal torques. Torque ratios were then calculated. Using the same Instron machine with TADs fully inserted in the artificial bone (2 per design per angle), pull-out tests were performed at angles of 0° / 30° / 60° / 90°. The TADs were …

    bu Repository record for The elaboration of a novel TAD design and its comparison to an industrial design (opens in a new tab)