Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 1528 for “"Replacements"”.

  1. Impingement in total hip replacements

    … common reason for early failure in total hip replacements (THRs) and occurs following impingement. Impingement is the unwanted contact between either the component and/or bone around the THR. This thesis investigates the effect of factors such as patient bony anatomy, patient activity and cup …

    whiterose Download PDF for Impingement in total hip replacements (opens in a new tab)

  2. Torques in total hip replacements

    … at the articulating interface of total hip replacements (THRs), if transferred, have the potential to affect component fixation and/or induce micro motion linked to fretting and corrosion at modular junctions. Pre-clinical testing of friction behaviour in THRs has predominantly been assessed …

    whiterose Download PDF for Torques in total hip replacements (opens in a new tab)

  3. Tribocorrosion of total hip replacements

    The performance of metal-on-metal total hip replacements is largely determined by their propensity to degrade in vivo. Degradation occurs through the complex interactions between wear and corrosion (termed tribocorrosion) and leads to the production of metallic particulate debris and metallic ions. …

    whiterose Download PDF for Tribocorrosion of total hip replacements (opens in a new tab)

  4. Biomechanical Comparison of Lumbar Disc Replacements

    … It was also hypothesized that either disc replacements offered preservation of harvested motion at all motion levels whereas the pedicle screw fixation would not. Using a previously established non-destructive testing protocol, measurements of motion and flexibility were obtained. Seven …

    tenn-hsc Repository record for Biomechanical Comparison of Lumbar Disc Replacements (opens in a new tab)

  5. Integrating sensors into total hip replacements

    Total hip replacement (THR) is a successful intervention for late stage osteoarthritis. The NJR reported in 2022, that 100,000 total hip replacement (THR) surgeries were performed in England, Wales and N.Ireland . Use of THR is increasing and younger patients are receiving THRs. Implants need to be …

    whiterose Download PDF for Integrating sensors into total hip replacements (opens in a new tab)

  6. Biomechanical Evaluation of Total Ankle Replacements

    Globally, 1% of the population is affected by arthritis of the foot and ankle. Total ankle replacement (TAR) was developed as an alternative to fusion to treat end-stage arthritis, however failure rates are relatively high and are often related to bony damage. The purpose of this PhD was to develop …

    whiterose Download PDF for Biomechanical Evaluation of Total Ankle Replacements (opens in a new tab)

  7. Properties of elastomers for small-joint replacements

    Silicones are used to manufacture finger and wrist joints. However these joints have fractured prematurely in vivo. There is a lack of literature on the mechanical properties of silicones. The aim of this thesis was to investigate the viscoelastic and related properties of elastomers such as …

    birmingham Download PDF for Properties of elastomers for small-joint replacements (opens in a new tab)

  8. Multi-Network Hydrogels for Synthetic Cartilage Replacements

    Hydrogels that could replace damaged cartilage offer potential advantages versus biological grafting. However, existing hydrogels fail to mimic the complex and unique properties of cartilage tissues, namely the combination of hydration, rigidity, and strength. Herein, a series of triple network …

    tamu Repository record for Multi-Network Hydrogels for Synthetic Cartilage Replacements (opens in a new tab)

  9. CoCrMo alloys in hip and knee replacements application

    CoCrMo alloys have been widely used in hip replacements. On the one hand, they have exhibited excellent long-term survival rates, but recently high failure rates have been observed, associated with adverse local tissue reactions. It is still a puzzle why CoCrMo alloys sometimes work very well, …

    whiterose Download PDF for CoCrMo alloys in hip and knee replacements application (opens in a new tab)

  10. Contact mechanics of metal on polyethylene hip replacements

    Metal-on-ultra high molecular weight polyethylene (UHMWPE) total hip replacement (THR) has been the most popular and clinically successful hip prosthesis to date. The long-term performance of THR depends on both the tribological characteristics and biomechanical behaviour of the prosthesis. This …

    whiterose Download PDF for Contact mechanics of metal on polyethylene hip replacements (opens in a new tab)

  11. Numerical Simulation of Wear of Total Knee Replacements

    In this work we discuss the design and implementation of a computer program to simulate the wear on knee implants over a standardized gait cycle. The contact problems during the gait cycle are formulated using linear elasticity with a linear non-penetration condition. Archard's wear law is used to …

    qucosa-diss

  12. Iodine content in meal replacements in the U.S.

    … sources of balanced nutrition. Twenty-seven meal replacements from supermarkets in the Boston area were analyzed to measure their levels of iodine in order to determine how meal replacements may contribute to iodine deficiency or excess. Overall mean ± SD iodine content was 49.7 ± 125.4 …

    bu Repository record for Iodine content in meal replacements in the U.S. (opens in a new tab)

  13. C4F7N and Mixtures as SF6 Replacements: Breakdown and Impact

    The suitability of pure C4F7N and some mixtures as a replacement for SF6 are evaluated. A stainless steel chamber is developed to withstand pressures up to 6.8 atm. A spark gap with fixed 2.2 mm gap is deigned to maintain a coaxial structure around the breakdown event. Custom voltage and current …

    ttu Repository record for C4F7N and Mixtures as SF6 Replacements: Breakdown and Impact (opens in a new tab)

  14. Wear and Boundary Lubrication in Modular Total Knee Replacements

    … can lead to failure of modular total knee replacements and make expensive revision surgery necessary. Gamma-in-air sterilization of the PE insert and having a modular tibial component are both risk factors for excessive backside wear that contribute to osteolysis and implant failure. The …

    waterloo Repository record for Wear and Boundary Lubrication in Modular Total Knee Replacements (opens in a new tab)

  15. SCRATCH DAMAGE EVOLUTION ON METALS IN TOTAL JOINT REPLACEMENTS

    The goal of total joint replacement (TJR) is to replace nonfunctioning joint components and relieve pain, improve quality of life, and to improve joint function. Although TJR is a successful procedure, more than 54,000 knee revisions occur each year due to factors, such as wear, loosening, …

    clemson Repository record for SCRATCH DAMAGE EVOLUTION ON METALS IN TOTAL JOINT REPLACEMENTS (opens in a new tab)

  16. Evaluation of Fluid Diodes as Pulmonary Heart Valve Replacements

    … There currently is not a permanent option for a replacements valve. Therefore, a need exists to develop a permanent solution. Knowing that the right heart circulation is more tolerant of moderate levels of regurgitation (0 - 35%) and pressure gradient (0 - 30 mmHg), this study investigates the …

    clemson Repository record for Evaluation of Fluid Diodes as Pulmonary Heart Valve Replacements (opens in a new tab)

  17. Polyethylene acetabular liner rim damage in total hip replacements

    Total hip replacement surgery is a successful orthopaedic intervention with over 90,000 procedures carried out annually; however, some implants still fail. The failure of THRs in the first year have been related to mechanical failure, such as dislocation and/or implant fracture. The mechanical …

    whiterose Download PDF for Polyethylene acetabular liner rim damage in total hip replacements (opens in a new tab)

Page 1 of 77