Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 115 for “"Residual limb"”.
-
Transtibial Prosthesis Insert to Accommodate Residual Limb Volume Change
… year after amputation, individuals with lower limb amputations often require multiple prosthetic sockets to accommodate changes in residual limb volume and shape. This frequent need for new sockets arises as the limb matures, posing a challenge for both amputees and prosthetists. Digital …
-
Electromagnetic suspension system for prosthetic limbs that compensates for residual limb shrinkage
When an amputation of a lower limb occurs, forces due to walking are absorbed by the soft tissues of the residual limb. Due to the soft tissues of the limb no being accustomed to handling such high forces, one of the major issues that occurs is residual limb shrinkage. As the amount of pressure …
-
Investigating the mechanisms of soft tissue damage at the residual limb-socket interface
The residual limb tissues of an individual with below knee amputation form a critical loaded interface with the prosthetic limb. In the early stages of rehabilitation, residual limb tissues have not been conditioned to support loading and are vulnerable to damage. This impacts upon quality of life …
-
Predicting Pressure Distribution Between Transfemoral Prosthetic Socket and Residual Limb Using Finite Element Analysis
… determine the pressure distribution between the residual limb and the prosthetic socket of a transfemoral amputee. This analysis was performed in an attempt to develop a process allowing healthcare providers and engineers to simulate the fit and comfort of transfemoral prosthetics to reduce the …
-
Realization of a Measuring Device for Recordning the Relative Movement between Residual Limb and Prosthetic Socket
Relative motion between residual limb and prosthetic socket is an indication of poor fit. Both the fabrication and fitting processes are highly subjective and a favorable result depends upon the technician's expertise. Although numerous methods exist to measure the relative motion, all have …
-
Measurement of factors affecting fit at the prosthetic socket-residual limb interface in people with transtibial amputation
… amputation rate the fit between their residual limb and prosthetic socket as the most important factor in the use of their prosthesis. Current research suggests that poor fit between the residual limb and the prosthetic socket can cause pain, skin breakdown or alteration of gait. This …
-
Quantification of Transhumeral Prosthetic Socket Residual Limb Interface Movement Using Motion Capture and a Slip Detection Sensor
… of the forces and motions occurring between the residual limb and prosthesis and how they can be used to influence socket design and fitting. Prosthetic socket fitting and prescription would benefit from an elegant method for comparing socket designs. This dissertation focuses on the development …
-
Finite Element Modelling of Residual Limb and Transtibial Prosthesis Socket to Predict Interfacial Pressure Considering Muscle Contraction
A lower-limb prosthesis is a mechanical device that replaces part of a biological limb to restore mobility. Approximately 7,400 lower-limb amputation surgeries are performed in Canada each year. The tissues in the residual limb (the "residuum") experience atypical stresses. Importantly, the distal …
-
Development of a biomechanical model of the interface between the residual limb and prosthesis for trans-femoral amputees
… to predict the biomechanical behaviour at the residual limb / socket interface for the purpose of obtaining a quantitative evaluation of socket fit. Three dimensional FE models of the residual limb of trans-femoral amputees were generated based on geometrical data obtained using a mechanical …
-
Development of a Pressure Sensing System Coupled with Deployable Machine Learning Models for Assessing Residual Limb Fit in Lower Limb Prosthetics
Lower limb amputations pose significant challenges for patients, with over 150,000 cases annually in the U.S., leading to a high demand for effective prosthetics. However, only 43% of lower limb prosthetic users report satisfaction, primarily due to issues with socket fit, which is critical for …
-
Biomechanical Model of Transhumeral Prostheses
… the interface between the prosthetic socket and residual limb (S-RL) interface is an important factor in determining acceptance and outcomes of upper limb prostheses. [1] Among the most common complaint from amputees is that the prosthesis is uncomfortable due to developing skin irritation which …
-
The effect of transverse rotation and longitudinal translation between prosthetic components during the gait of unilateral trans-tibial amputees
… considerable forces are transmitted across the residual limb socket interface. These loads and associated gait patterns can be altered by introducing compliant elements into the prosthesis. However, previous studies have failed to adequately describe the effects that components with such …
-
A Sensor for Three-Dimensional Limb-to-Prosthesis Interface Motion and Physiological Adaptations from Lower Extremity Prosthesis Use
… changes to the skin and underlying tissue of the residual limb. As prosthesis socket fit is considered one of the most integral elements of increasing the likelihood a user adopts their artificial limb, it is crucial to understand how the limb interacts with the prosthesis at the contact …
-
Large-Scale Soft Tactile E-Skin Development and Testing: Towards Advancing Upper Limb Prosthetic User Discomfort Monitoring
… of the discomfort experienced by upper limb prosthetic users. <br/>Discomfort is a major factor contributing to prosthetic abandonment. Residual (amputated) limb swelling, shrinking, and the interfacial pressures that occur between the residual limb and the worn prosthetic limb, are …
-
Development of software to estimate pressures on the residual limbs of amputees by means of a pylon mounted transducer
… the foot through the pylon to the socket and the residual limb. By placing a transducer on the pylon at the base of a socket, the forces and moments that are directed into the socket can be measured. It can be hypothesized that this information can be used to estimate the intra-socket pressures …
-
A Pneumatically Actuated Reconfigurable Socket for Transtibial Amputees
A poor fit between the residual limb of a below knee amputee and the prosthetic socket can cause pain, skin breakdown, or gait alteration. Studies suggest key aspects of socket fit relate to residual limb pressure distribution and volume fluctuations. While soft inflatable actuators inside the …
-
A Benchtop Analysis of Pressure Offloading Associated With Custom Socket Inlays in Transtibial Prostheses
Approximately 78% of people with lower limb amputations are dissatisfied with the comfort of their prostheses (Quintero-Quiroz & Perez 2019). In the case of lower limb amputations, the residual limb tissue bears far more weight than it was before the amputation. The pressure put on the soft tissue …
-
A wearable platform for monitoring the tissue viability of lower limb amputees
Around the world the incidence of lower limb amputation is on the rise. These rising numbers puts a huge constraint on the health care resources, thereby making the rehabilitative process challenging for both the healthcare services as well as the amputee. People with a lower limb amputation need …
-
A Simulation-Based Framework for Informing Design of Prosthetic Feet
Individuals with lower limb amputation face a variety of conditions associated with decreased quality of life, including elevated metabolic cost during ambulation, gait asymmetry, and a variety of psychological disorders. Sustained prosthesis use may also induce overloading of joints, leading to …
-
Flexible Electronics for High-Density EMG Based Signal Acquisition for Upper Limb Myoelectric Prosthesis Control
… electrodes for high-density control of an upper limb myoelectric prosthesis. Different flexible dry electrode materials (made from doped traditionally non-conductive substrates) were used and compared to titanium (which is the industry standard for EMG electrodes). We determined that conductivity …
Page 1 of 6