Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 109 for “"Resistance measurement"”.

  1. Nodal Resistance Measurement System

    The latest development in the measurement techniques has resulted in fast improvements in the instruments used for measurement of various electrical quantities. A common problem in such instruments is the automation of acquiring, retrieving and controlling the measurements by a computer or a …

    unt Repository record for Nodal Resistance Measurement System (opens in a new tab)

  2. Thermal Contact Resistance Measurement and Related Uncertainties

    Thermal contact resistance is an important parameter in detailed thermal analysis and design of aerospace systems. The ability to determine thermal contact resistance reliably can have a significant impact on the fidelity of thermal models—particularly for space applications. The 2004 NASA Langley …

    odu Repository record for Thermal Contact Resistance Measurement and Related Uncertainties (opens in a new tab)

  3. A new surface resistance measurement method with ultrahigh sensitivity

    … and fabricated to study residual surface resistance of planar superconducting materials. Unlike many other structures where the test samples are placed in strong magnetic field positions, the edge of a 25.4 mm or larger diameter sample in the triaxial cavity is located outside the strong …

    vt Repository record for A new surface resistance measurement method with ultrahigh sensitivity (opens in a new tab)

  4. High temperature resistance measurement system for solid oxide fuel cell circuit pastes

    … that reduces the overall electrical contact resistance and exhibits good stability is needed. Silver nickel circuit pastes are expected to be dense, mechanically strong and have higher conductivity than other high temperature alloys, or conductive ceramics. High performance silver pastes …

    msu Repository record for High temperature resistance measurement system for solid oxide fuel cell circuit pastes (opens in a new tab)

  5. Direct current electrical resistance measurement techniques for assessment of colorectal cancer during laparoscopic surgery

    … and systematic testing of a biogalvanic measurement system with porcine tissues showed variation that is not explained using the current system model. Correlation with electrochemical measurements verified this unaccounted system complexity. Electrode polarisation and diffusion controlled …

    whiterose Repository record for Direct current electrical resistance measurement techniques for assessment of colorectal cancer during laparoscopic surgery (opens in a new tab)

  6. Direct current resistance measurement structure for determining line width and metal thickness variations in surface acoustic wave devices.

    … devices cause difficulties in obtaining accurate measurement of the centre frequency of the bandpass reponse of unpackaged SAW devices. The variation in centre frequency of SAW devices due to fabrication variation is dependent on the variation of the width and thickness of the metal fingers of the …

    ottawa-retro Repository record for Direct current resistance measurement structure for determining line width and metal thickness variations in surface acoustic wave devices. (opens in a new tab)

  7. Advanced optimization preocedures for lithium-ion battery insertion cathodes

    … and cost efficiency. A special focus was on the measurement and assessment of the electronic conductivity of cathodes. Electrode slurries with varying formulations were prepared and coated, examining the effects of cathode active materials (CAMs), binders, and conductive additives (CAs). …

    qucosa-diss Repository record for Advanced optimization preocedures for lithium-ion battery insertion cathodes (opens in a new tab)

  8. Precision rectifier detectors for AC resistance bridge measurements with application to temperature control systems for irradiation creep experiments

    <p>The suitability of several temperature measurement schemes for an irradiation creep experiment is examined. It is found that the specimen resistance can be used to measure and control the sample temperature if compensated for resistance drift due to radiation and annealing effects. A modified …

    utk-theses Repository record for Precision rectifier detectors for AC resistance bridge measurements with application to temperature control systems for irradiation creep experiments (opens in a new tab)

  9. In-Situ Micro Testing Techniques for Electro-Thermo-Mechanical Characterization of Nano/micro-Scale Materials

    … from thermal mismatch. Also, 4-point electrical resistance measurement was performed on 100-nm thick Al film. Its temperature-dependent response was normal metallic linear behavior except that the initial resistivity was about 10 times higher than the bulk value.

    uiuc Repository record for In-Situ Micro Testing Techniques for Electro-Thermo-Mechanical Characterization of Nano/micro-Scale Materials (opens in a new tab)

  10. Chemistry and interfacial mechanics of a phase change material on metal surfaces

    … up over half, for many new devices. A thermal resistance measurement setup has been designed and assembled ASTM D5470 standard as guidelines. The equipment was then be used to study the interfacial chemistry and mechanics of a thermal interface material called phase change material The …

    nus Repository record for Chemistry and interfacial mechanics of a phase change material on metal surfaces (opens in a new tab)

  11. Kinetics and mechanisms of metal silicide formation

    … Si bilayers using a combination of in situ sheet resistance measurement, in situ stress measurement, x-ray diffraction, transmission electron microscopy (TEM), scanning transmission electron microscopy, and Auger electron spectroscopy (AES). Studies of the initial stage of the C49-TiSi$\sb2$ …

    uiuc Repository record for Kinetics and mechanisms of metal silicide formation (opens in a new tab)

  12. IMPROVING HIGH-FREQUENCY LOCK-IN MEASUREMENTS IN DEVICES WITH POOR ELECTRICAL CONTACTS

    Accurate resistance measurement of two-dimensional material devices is essential for characterizing their intrinsic electronic properties. While lock-in amplification is widely used to enhance sensitivity and reduce low-frequency noise, the presence of 1/f noise necessitates operating at kilohertz …

    nus Repository record for IMPROVING HIGH-FREQUENCY LOCK-IN MEASUREMENTS IN DEVICES WITH POOR ELECTRICAL CONTACTS (opens in a new tab)

  13. Reactions of thin film bilayers of nickel on silicon-germanium alloys

    … analytical techniques: An in-situ 4-point probe resistance measurement, done during vacuum annealing of the bilayers, yields information about changes in the whole electrically conductive volume of the film structure. In-situ X-ray Photoelectron Spectroscopy (XPS) is also done during vacuum …

    uiuc Repository record for Reactions of thin film bilayers of nickel on silicon-germanium alloys (opens in a new tab)

  14. Fabrication and characterisation of nickel manganite thin films by pulsed laser deposition

    … scanning electron microscopy (SEM). A four-wire resistance measurement technique was also carried out to measure the resistance and to calculate the films electrical parameters. Optimisation of the deposition parameters enabled films to be produced which exhibit characteristic negative …

    birmingham Repository record for Fabrication and characterisation of nickel manganite thin films by pulsed laser deposition (opens in a new tab)

  15. Electrical resistivity as a measure of change of state in substrates: Design, development and validation of a microprocessor-based system.

    … health monitoring and energy saving. Electrical resistance could potentially serve as an indicator of structural well-being or damage in the structure. To this end, the development of a microprocessor-based automated resistance measurement system with customized GUI is desired. In this research, …

    unt Repository record for Electrical resistivity as a measure of change of state in substrates: Design, development and validation of a microprocessor-based system. (opens in a new tab)

  16. A tracheoesophageal puncture voice prosthesis

    … pressure during coughing. Periscope valve air resistance tests have been performed. The side valve used in the designed voice prosthesis demonstrates lower resistance compared to the duckbill valve in both bench and in vivo tests within the range of flows required for ordinary speech. In …

    njit Repository record for A tracheoesophageal puncture voice prosthesis (opens in a new tab)

  17. Conductive anodic filament reliability of fine-pitch through-vias in organic packaging substrates

    … Characterization studies included gravimetric measurement of moisture sorption, extractable ion content analysis, electrical resistance measurement, impedance spectroscopy measurement, optical microscopy and scanning electron microscopy analysis and elemental characterization using energy …

    gatech Repository record for Conductive anodic filament reliability of fine-pitch through-vias in organic packaging substrates (opens in a new tab)

  18. An Experimental Investigation of Composite Sensors for Crack Length Measurement

    … available. In this thesis, bondable crack length measurement gages have been investigated and these gages give electrical signal as the output and measure the crack length continuously. Silver paint, nickel powder impregnated epoxy and carbon powder impregnated polymer composite gages are …

    odu Repository record for An Experimental Investigation of Composite Sensors for Crack Length Measurement (opens in a new tab)

Page 1 of 6